Thermocet Apertura series Скачать руководство пользователя страница 1

Page.1 

OPERATING AND INSTALLATION INSTRUCTIONS 

Apertura line 

Содержание Apertura series

Страница 1: ...Page 1 OPERATING AND INSTALLATION INSTRUCTIONS Apertura line...

Страница 2: ...tinguishing Warning Maintenance 3 Preparations for installing the Apertura Page 6 4 Installation instructions for the Apertura with concentric duct connection Page 7 General instructions Components of...

Страница 3: ...e appliance must be checked by the installer for gas tightness to gas and combustion products and the correct operation of the various components and functions In addition the flue system and the outl...

Страница 4: ...but this can also be done by pushing the timer button Setting the required temperature Press the auto button until the display starts to flash Use the high low buttons to set the required tempera ture...

Страница 5: ...e settings are adjusted by means of the auto and timer modes press one of the high low buttons in order to see whether the transmit symbol appears in the top left of the display and the green LED on t...

Страница 6: ...re extinguishing the appliance completely Now turn knob A1 to the right as far as it will go to position push the knob in and then turn it to position Warning After extinguishing the pilot light wait...

Страница 7: ...ead Section 5 Concentric duct system on page 8 before installing the ap pliance in connection with the necessity of fitting the restriction sheet First dismantle Front 11 12 or 13 depending on the ver...

Страница 8: ...terial See Page 15 A Position the log set as shown on Page 15 Do this with care since soot may be formed if the log set is wrongly positioned You finally position and fit the glass the glazing beads a...

Страница 9: ...tive length per bend 1 metre until the maximum pipe length of 12 metres is reached including bends but excluding vertical terminal The minimum length is 3 metres The outlet may oc cupy any position on...

Страница 10: ...allation of the vertical terminal The outlet can be placed at any arbitrary position on the roof surface inlet and outlet in identical pressure areas but must comply with the current regulations Use a...

Страница 11: ...ry I3p b I3p b I3p b I3p b I3p b I3p b Country NL SP FR BE DE GB Pre Pressure MBAR 50 30 37 30 37 30 37 30 50 50 37 30 Burner Pressure MBAR 36 29 4 36 29 4 36 29 4 36 29 4 36 29 4 36 29 4 Injection Bo...

Страница 12: ...Page 12 1...

Страница 13: ...Page 13 5 2 4 3...

Страница 14: ...Page 14 G25 G20 30 31 7 49 G25 55 G20 30 31 6...

Страница 15: ...Page 15 A...

Страница 16: ...Page 16 8 9 10 11 12...

Страница 17: ...Page 17...

Страница 18: ...Page 18 A E B C F I H G K L J M N O P...

Страница 19: ...KET 12965024 12965524 D NOT AVAILABLE E CONCENTRIC BEND 90 12965014 12965514 F WALL BAND ADJUSTABLE 12965026 G ADJUSTABLE LENGHT 250 12965006 H FLAT ROOF PLATE 12965020 12965520 I LOCKING BAND 1296503...

Страница 20: ...Page 20...

Страница 21: ...liance is fitted with insulated covering one of the following materials should only be used Loose white insulation wool heat resistant to 1000 C Rocktherm 180 012 insulation wool 700 C from Rockwool o...

Страница 22: ...ot covered by the guarantee Defects caused by inexpert assembly and or treatment Costs of transport assembly and dismantling Glazing fire gratings refractory stones flue gas baffle plates heat shields...

Отзывы: