background image

7

40.020.950 - rev. 01 - 2019

English

IMAC 4000 OIL US

2.4  

Control panel (Fig. 5)

A Indicator light, blue: Fan high speed

B Indicator light, blue: Fan low speed

C Indicator light, white: Panel is live

D Indicator light, orange: Burner low

E Indicator light, orange: Burner high

F Hour counter

G Pushbutton with indicator light, red: Fault

frequency controller and reset

H Indicator light, red: Maximum temperature

I Pushbutton with indicator light, red: Fault

burner and reset

J Switch for fan and burner settings:

- 0: The convector heater is switched off

- 1: Fan low speed

- 2: Fan high speed

- 3: Fan low speed; burner low

- 4: Fan high speed; burner low

- 5: Fan high speed; burner high

K Digital thermostat

2.5  

Digital thermostat/safety temp. limiter

The digital thermostat (K) has three functions:

• 

• 

• 

• 

2.6  

Accessories

• 

3  

PREPARATIONS

3.1  

Removing the packaging

1.   Remove packaging from the convector heater.

2.   Lift the convector heater to transport it to its

      location of use.

 

Caution

 

Lift the convector heater according to

 

the instructions on the labels.

3.2  

Installation

1.   Make sure the convector heater is level.

2.   Connect the fuel supply to the quick coupling

      (A) of the convector heater, see fig. 6.

3.   Fill the tank with fuel.

 

Warning - Air quality hazard

 

• Do not use this heater for heating

 

  human living quarters.

 

• Use of direct-fired heaters in the  

 

 

  construction environment can result in  

 

  exposure to levels of CO, CO2 and 

 

  NO2 considered to be hazardous to 

  

  health and potentially life threatening.

 

• Do not use in unventilated areas.

 

• Know the signs of CO and CO2 

 

  poisoning:

 

 

- Headaches, stinging eyes.

 

 

- Dizziness, disorientation.

 

 

- Difficulty breathing,

 

 

  feels of being suffocated.

 

• Proper ventilation air exchange 

 

  (OSHA  29 CFR 1926.57) to support 

 

  combustion and maintain acceptable air  

 

  quality shall be provided in accordance  

  

  with OSHA 29 CFR Part 1926.154, ANSI 

    

  A10 Safety Requirements for 

   

  Temporary and Portable Space Heating 

 

  Devices and Equipment used in the 

  

  Construction Industry or the Natural Gas 

  

  and Propane Installation Codes CSA 

  

  B149.1.

 

• Periodically monitor levels of CO, CO2 

 

  and NO2 existing at the construction site 

 

  - at the minimum at the start of the shift 

 

    and after 4 hours.

 

• Provide ventilation air exchange, either 

 

  natural or mechanical, as required to 

 

  maintain acceptable indoor air quality.

       

Fan thermostat:

After switching off the convector heater, the 

ventilator will continue to run. The ventilator 

will cool down the convector heater to prevent 

damage by overheating. As soon as the tem-

perature has dropped sufficiently, the thermo

-

stat will turn off the fan.

Burner thermostat:

The thermostat will stop the burner as soon 

as the temperature of the hot air has risen too 

much.

When the air temperature has dropped

sufficiently, the thermostat will turn on the

burner again.

Maximum thermostat:

The maximum thermostat will switch off the 

convector heater completely if an

overheating problem has occurred in the

convector heater. 

The safety thermostat will switch off

the header completely if an overheating

problem occurred.

The burner cannot be switched on again

until the thermostat has been reset by pressing 

the U key for two seconds.

Fuel tank

Thermostat for room temperature

Air-supply hose (diameter 500 or 600 mm)

Air-inlet panels (diameter 500 or 600 mm)

Hot air outlets (diameter 2 x 600 mm or 3 x

500 mm)

Содержание IMAC 4000 OIL US

Страница 1: ...IMAC 4000 OIL US USER MANUAL...

Страница 2: ...2 40 020 950 rev 01 2019 IMAC 4000 US A B C D E F G H I J K O P Q R 1 2 3 4...

Страница 3: ...3 40 020 950 rev 01 2019 IMAC 4000 US 6 5 7...

Страница 4: ...4 40 020 950 rev 01 2019 IMAC 4000 US Language English 5...

Страница 5: ...nty regulations Environment Note The convector heater is made of various metals and synthetic materials The heater also contains electronic parts which must be treated as electronic waste Please conta...

Страница 6: ...ignited by the spark between the electrodes The light of the flame that is created will activate the photocell This photocell checks whether a good combustion is brought about In case of poor or no c...

Страница 7: ...ches stinging eyes Dizziness disorientation Difficulty breathing feels of being suffocated Proper ventilation air exchange OSHA 29 CFR 1926 57 to support combustion and maintain acceptable air quality...

Страница 8: ...nimum distance is 1 m 5 Ensure that the heated air is allowed to flow freely The minimum distance between the outlet and any obstacle is 5 m 6 Check the ventilation surface per kW a surface area of 25...

Страница 9: ...ly before carrying out any maintenance 5 3 V belts Fig 7 Impression V belt tension 13 mm 32 2 N 1 Remove the upper and lower side panels A 2 Lower the motor B by turning the adjusting nuts C 3 Remove...

Страница 10: ...ect the air flow Reset the convector heater User 9 The combination thermostat is defective Replace the combination thermostat Dealer 10 The frequency controller is in disorder Reset the frequency cont...

Страница 11: ...nt and the amount of soot Dealer 26 The settings of the nozzle holder and or the forcer plate are incorrect or dirty Correct the settings of the nozzle holder and the forcer plate Clean the nozzle and...

Страница 12: ...es will not close Close the cock see fig 8 B User Contact your dealer Dealer The convector heater stops 35 An overheating problem has occurred in the convector heater Reduce the resistance at the outl...

Страница 13: ...ion Check the temperature resistance of the hose used Contact your dealer for information about the maximum length of the exhaust hoses bends manifolds and hose clamps The maximum static pressure in t...

Страница 14: ...14 40 020 950 rev 01 2019 IMAC 4000 OIL US English Date Description Maintenance or Failure Action by A...

Страница 15: ...15 40 020 950 rev 01 2019 English IMAC 4000 OIL US Date Description Maintenance or Failure Action by...

Страница 16: ...16 40 020 950 rev 01 2019 IMAC 4000 OIL US English IMAC 4000 A Fuel filter 41 520 031 B Nozzle C Electrodes block D Set of V belts 41 740 318 2xSPA 2240LW B...

Страница 17: ...18 000 24 000 24 000 CFM 10 595 14 715 14 715 Max pressure Pa 400 1000 700 Warm air T C 44 31 43 F 111 88 109 Current A 18 29 29 Nozzle SLW USG hr 6 00 60 S Fan thermostat C 35 F 95 Burner thermostat...

Страница 18: ...18 40 020 950 rev 01 2019 IMAC 4000 US...

Страница 19: ...care but Thermobile Industries B V cannot be held liable for possible errors in the information or the consequences thereof The information provided herein may not be reproduced and or published in an...

Страница 20: ...NDUSTRIES BV Konijnenberg 80 4825 BD Breda Nederland Postbus 3312 4800 DH Breda Nederland Bedrijfsnummer 3502 T 31 0 76 587 34 50 F 31 0 76 587 27 89 info thermobile com www thermobile com 40 020 950...

Отзывы: