FAULTS
6.1
Troubleshooting table
/i
During troubleshooting, make sure
that the mains voltage is switched on
and the gas supply is open.
Remove the bottom part of the
outside housing (GA42) and the
upper part of the outside housing (GA
60/85/110) for maintenance on the
internal parts.
Warning
Remove the mains plug from the
socket and shut off the gas supply
during repair.
Fault
Cause
Solution
Action
The heater does not
start up.
1
The heater has no volt-
age.
Check the electrical connec-
tion.
User
2
The fan motor runs
heavily or is blocked.
Check if the fan motor is dirty
or blocked.
User
Replace the fan motor.
Dealer
3
The thermostat is set to
a too low temperature.
Correct the settings.
User
4
There is no through-
connector on the ther-
mostat connection.
Fit the through-connector.
User
5
Defect in the operating
Filter at the differential
pressure switch
is clogged.
Replace filter.
panel
Repair or replace the operat-
ing panel
Dealer
User
The heater triggers a
fault; the red lamp on
the operating panel
lights up.
The mains plug has
6
7
8
been incorrectly inserted
into the socket.
Reverse the plug.
User
The earth of the socket
is not OK.
Have the earth of the socket
check by a recognised
installer.
User
The heater triggers a
fault; the red
and
yellow
lamp
s
on the
operating panel light
up.