Thermo 6464K Скачать руководство пользователя страница 21

OM6464K Rev. 4    11 January 2004

Page 21 of 24

                                  Warranty
Thermo warrants that the Products will operate 

substantially in conformance with Thermo’s Specifications 
applicable to such Products, when subjected to normal, 
proper and intended usage by properly trained personnel, 

for a period of twenty-four (24) months from the date of 
installation, not to exceed thirty (30) months from date of 
shipment from Thermo (the “Warranty Period”).  Thermo 

agrees during the applicable Warranty Period, provided it is 
promptly notified in writing upon the discovery of any 
defect and further provided that all costs of returning the 

defective Products to Thermo are pre-paid by Purchaser, to 
repair or replace, at Thermo's option, non-conforming 
Products so as to cause the same to operate in substantial 

conformance with said Specifications. Such repair shall 
include parts only during the final twelve (12) months of 
the Warranty Period. Replacement parts may be new or 

refurbished, at the election of Thermo.  All replaced parts 
shall become the property of Thermo.  Lamps, fuses, bulbs 
and other expendable items are expressly excluded from 

the warranty.  Thermo's sole liability with respect to 
equipment, materials, parts or software furnished to 
Thermo by third party suppliers shall be limited to the 

assignment by Thermo to Purchaser of any such third party 
supplier's warranty, to the extent the same is assignable.  
In no event shall Thermo have any obligation to make 

repairs, replacements or corrections required, in whole or in 
part, as the result of (i) normal wear and tear, (ii) accident, 
disaster or event of force majeure, (iii) misuse, fault or 
negligence of or by Purchaser, (iv) use of the Products in a 

manner for which they were not designed, (v) causes 
external to the Products such as, but not limited to, power 
failure or electrical power surges, (vi) improper storage of 

the Products or (vii) use of the Products in combination 
with equipment or software not supplied by Thermo.  If 
Thermo determines that Products for which Purchaser has 

requested warranty services are not covered by the 
warranty hereunder, Purchaser shall pay or reimburse 
Thermo for all costs of investigating and responding to 

such request at Thermo's then prevailing time and 
materials rates.  If Thermo provides repair services or 
replacement parts that are not covered by the warranty, 

Purchaser shall pay Thermo therefore at Thermo's then 
prevailing time and materials rates.  ANY INSTALLATION, 
MAINTENANCE, REPAIR, SERVICE, RELOCATION OR 

ALTERATION TO OR OF, OR OTHER TAMPERING WITH, 
THE PRODUCTS PERFORMED BY ANY PERSON OR 
ENTITY OTHER THAN THERMO WITHOUT THERMO'S 

PRIOR WRITTEN APPROVAL, OR ANY USE OF 
REPLACEMENT PARTS NOT SUPPLIED BY THERMO, 
SHALL IMMEDIATELY VOID AND CANCEL ALL 

WARRANTIES WITH RESPECT TO THE AFFECTED 
PRODUCTS.

THE OBLIGATIONS CREATED BY THIS SECTION TO 
REPAIR OR REPLACE A NON-CONFORMING PRODUCT 
SHALL BE THE SOLE REMEDY OF PURCHASER IN THE 

EVENT OF A NON-CONFORMING PRODUCT.  EXCEPT AS 
EXPRESSLY PROVIDED IN THIS WARRANTY, THERMO 
DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR 

IMPLIED, ORAL OR WRITTEN, WITH RESPECT TO THE 
PRODUCTS, DELIVERABLES AND SERVICES, INCLUDING 
WITHOUT LIMITATION ALL IMPLIED WARRANTIES OF 

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS 
FOR ANY PARTICULAR PURPOSE.  THERMO DOES NOT 
WARRANT THAT THE PRODUCTS, DELIVERABLES AND 

SERVICES, ARE ERROR-FREE, OR WILL ACCOMPLISH 
ANY PARTICULAR RESULT.  FURTHER, WITH RESPECT 
TO ANY SOFTWARE PRODUCT OR LICENCED 

SOFTWARE, PROVIDED TO PURCHASER HEREUNDER, 
THERMO MAKES NO REPRESENTATIONS OR WARRANTY 
THAT ALL ERRORS HAVE BEEN OR CAN BE ELIMINATED 

FROM THE SOFTWARE, THAT IT WILL OPERATE 
WITHOUT INTERRUPTION OR THAT IT WILL OPERATE 
WITH OTHER PRODUCTS.  THERMO EXPRESSLY 

DISCLAIMS ANY WARRANTY WHATSOEVER WITH 
RESPECT TO ANY OTHER THIRD PARTY PRODUCTS 
WHETHER LICENSED OR SOLD TO PURCHASER 

DIRECTLY BY A THIRD PARTY VENDOR OR SUBLICENSED 
OR RESOLD TO PURCHASER BY THERMO.  Thermo 
warrants that the Services provided hereunder will comply 
with the requirements expressly set forth in the terms and 

conditions set forth in this warranty hereto and will 
otherwise be performed in accordance with generally 
accepted industry practice by competent personnel.  In the 

event that any Services fail to comply with the foregoing 
standard, Thermo will, at its option, provided it is promptly 
notified in writing upon discovery of such failure, either 

repeat such non-complying Services at no additional charge 
or refund to Purchaser all fees theretofore paid by 
Purchaser with respect to such non-complying Services.  

Notwithstanding the foregoing, the cost of any such repeat 
of Services which generates results consistent with the 
original results will be at Purchaser’s expense.  THE 

FOREGOING WARRANTY IS THE SOLE AND EXCLUSIVE 
WARRANTY GIVEN BY THERMO IN CONNECTION WITH 
THE SERVICES PERFORMED HEREUNDER, AND IS IN LIEU 

OF ALL OTHER WARRANTIES OF ANY KIND, WHETHER 
EXPRESS OR IMPLIED, ORAL OR WRITTEN.”

 

www.thermo.com

Copyright © 2004 by Thermo Electron Corporation
All rights reserved. No part of this work may be reproduced or transmitted in any form 
or by any means, electronic or mechanical, including photocopying and recording, or 
by any information storage or retrieval system, except as may be expressly permitted 
in writing by Thermo Electron Corporation.  Printed in the United States of America.

Содержание 6464K

Страница 1: ...EC Centra CL5 and CL5R Centrifuges OM6464K Rev 4 11 January 2004 CL5 VENTILATED Cat No 6464K 120 VAC 60Hz Cat No 6465K 220 240 VAC 50 60Hz CL5R REFRIGERATED Cat No 6466K 120 VAC 60Hz Cat No 6467K 220 240 VAC 50 60Hz Instruction Manual ...

Страница 2: ......

Страница 3: ... 1 Rotor and Accessories 6 3 2 Starting and Stopping a Run 7 3 3 Stored Programs 8 3 4 Rotor Recognition System 8 3 5 Refrigeration IEC Centra CL5R only 8 3 6 Front Panel 9 3 7 Diagnostic Messages and Error Codes 10 4 Applications 11 4 1 Introduction 11 4 2 Speed and Force Tables 12 4 3 Derating Tables for Dense Samples 14 4 4 Chemical Resistance Table 15 4 5 Decontamination Table 16 4 6 RCF Nomog...

Страница 4: ...OM6464K Rev 4 11 January 2004 Page 4 of 24 ...

Страница 5: ...nual is written for centrifuge operators In addition to operation information it contains a few basic troubleshooting techniques and a chapter on maintenance This manual is not a guide for servicing centrifuge units Warnings Cautions and Notes WARNING WARNING A WARNING advises against certain actions or situations that could result in personal injury CAUTION A CAUTION advises against actions or si...

Страница 6: ...its new location ensure that the suction cups adhere correctly to the work surface 3 Operation 3 1 Rotor and Accessories A balanced load is essential for all centrifuges An unbalanced load produces vibration and can damage the unit ALWAYS balance containers on opposite sides of the rotor NOTE A 2 gram load imbalance at a speed of 4600 RPM imparts force equivalent to 20 pounds 9 1 kg at rest Always...

Страница 7: ...ions 1 5 and 10 14 or 7 3 and 16 12 3 Load six tubes at positions 1 9 5 and 14 18 10 or 7 9 3 and 12 18 16 4 Loading an odd number of tubes is not recommended Rotor Removal To remove the rotor 1 If your rotor has a dic remove this first by loosening the nut 2 Using the wrench provided loosen the rotor locking nut 3 Remove the wrench 4 Remove the locking nut 5 Lift the rotor off the shaft 3 2 Start...

Страница 8: ...ther with its default radius if not explicitly entered to the program Recall Program 1 Press the PROGRAM key to enter program mode 2 Select the appropriate program number by entering the desired program number on the numeric key pad and press ENTER The program s set parameters will display 3 Press START to begin this run Lock Program Unlock Program To lock a program to prevent changes to the progr...

Страница 9: ...lay indicates relative centrifugal force in units of g Use the numeric keys to change the set speed or force Select speed in increments of 50 RPM from 500 through 15 000 RPM depending on the max allowable speed limit for the particular rotor Select RCF from 500 21 000 xg depending on the max allowable RCF limit for the particular rotor in increments of 50 xg ROTOR RADIUS SPEED RPM RCF Press these ...

Страница 10: ... 3 7 Diagnostic Messages and Error Codes The beeper sounds in these situations Two times on power up Three times at the end of a spin Five times when a warning occurs Diagnostics Diagnostic messages appear in place of the speed display in the following cases Message Description bAL bAL indicates an unbalanced rotor Open the cover to erase this message Verify that a balanced load is installed Inspe...

Страница 11: ... Direction of Rotation The microprocessor discovered wrong direction of rotation during acceleration Warnings during a spin LId PFAIL and dIR error messages can occur during a spin In this case the rotor brakes or coasts to a stop and the run ends 4 Applications 4 1 Introduction This section describes the use of specific rotors and accessories More detailed information is shipped with the rotor or...

Страница 12: ...6 2 pr x 6559E 4 x 100 ml sealed Round bottom 38x111 mm 4500 3940 17 4 2 pr x 6557E 8 x 50 mL sealed Corning 8240 50 Thermo Electron 2997 4500 3980 17 6 2 pr x 6556E 8 x 50 mL sealed Falcon Corning conical 4500 3980 17 6 2 pr x 6560E 12 x 25 30 mL sealed Universal 25 x 107mm 4500 3400 15 0 2 pr x 6568E 20 x 15 mL sealed Falcon Corning conical 4500 3980 17 6 2 pr x 6561E 20 x 10 ml sealed Kova Uris...

Страница 13: ...earest 50 rpm or 50 xg Tube Maximum Radius Tube Adapter No x Vol ml Description RPM RCF Quantity x Cat No 24 x 1 5 2 0 mL 11x54 mm microtube 15000 21000 8 35 24 x 0 5 mL 8 x 54 mm microtube 15000 17432 6 93 24 x 0 5 mL 8 x 54 mm microtube 15000 18740 7 45 2 pr x 5763E 24 x 0 4 mL 6 x 50 mm microtube 15000 21000 8 35 2 pr x 5764E 24 x 0 25 mL 6 x 50 mm microtube 15000 18240 7 25 2 pr x 5764E Tube M...

Страница 14: ...700 RPM 4 000 x 925 3 700 Specific gravities greater than 3 0 This table is based on the formula Use the same formula to compute derating factors for specific gravities greater than 3 0 S0 is the maximum specific gravity allowed before derating 1 2 Sa is the actual specific gravity of the sample CAUTION Do not exceed the rated speed or specific gravity Higher speeds or specific gravities will impo...

Страница 15: ...irs For Oxidizing Acids see Oxidizing Agents strong Derating Table for Microplate Rotor Load per Carrier grams Max Speed rpm 320 3650 340 3550 360 3450 380 3400 400 3300 450 3100 500 2950 600 2700 Greater than 600 do not use Plastic Metal Other POLYALLOMER POLYCARBONATE POLYETHYLENE POLYPROPYLENE POLYURETHANE MODIFIED PHENYLENE OXIDE NORYL ACETAL HOMOPOLYMER DELRIN ACETAL COPOLYMER CELCON NYLON PO...

Страница 16: ...EL ALUMINUM MAGANESE BRONZE MAGNESIUM RUBBER BUNA N VITON PHENOLIC FIBER PT PAINTED SURFACE Mechanical Autoclave S M U S M U S S S U S S S S S S S M S M Ethylene Oxide Gas S S S S S S S S S S S S S S S U U S S S Dry Heat 2Hrs 160 C U U U U U U U U U U S S U S S U U U U U Chemical Ethanol S S S S U S S S U M S S S S S S S S S S 40 Formalin S S S S U S S S S U S S S S S S U S S S Methanol S M S S M ...

Страница 17: ...OM6464K Rev 4 11 January 2004 Page 17 of 24 4 6 RCF Nomograph ...

Страница 18: ... remove the corrosion discontinue use of the product and inform technical service 5 3 Storage Keep the Unit Dry Store parts on a soft surface to avoid damage Rotors and other parts should be clean and dry Store them open to the air not in a plastic bag so any residual moisture evaporates Face the parts upward to avoid moisture retention in the cavities 5 4 Decontamination Procedures WARNING WARNIN...

Страница 19: ...y 9 to 40 C by 1 Rotation Counterclockwise RPM 500 15 000 by 50 RPM RCF 50 21 000xg by 50 xg Spin Duration 0 99 min 59 sec by 1 min and or 1 sec HOLD MODE Momentary Spin Brake Active Electric 3 profiles Repeatability Temperature Control IEC Centra CL5R only 2 C within range of 4 C to ambient Rotation Accuracy within 10 RPM Timer Microprocessor controlled Accuracy within 1 sec System Components Mot...

Страница 20: ...OM6464K Rev 4 11 January 2004 Page 20 of 24 ...

Страница 21: ...ANY PERSON OR ENTITY OTHER THAN THERMO WITHOUT THERMO S PRIOR WRITTEN APPROVAL OR ANY USE OF REPLACEMENT PARTS NOT SUPPLIED BY THERMO SHALL IMMEDIATELY VOID AND CANCEL ALL WARRANTIES WITH RESPECT TO THE AFFECTED PRODUCTS THE OBLIGATIONS CREATED BY THIS SECTION TO REPAIR OR REPLACE A NON CONFORMING PRODUCT SHALL BE THE SOLE REMEDY OF PURCHASER IN THE EVENT OF A NON CONFORMING PRODUCT EXCEPT AS EXPR...

Страница 22: ...OM6464K Rev 4 11 January 2004 Page 22 of 24 Notes ...

Страница 23: ...OM6464K Rev 4 11 January 2004 Page 23 of 24 ...

Страница 24: ...2778 1101 Fax 91 22 2778 1103 Bangaalore India 81 45 453 9122 Fax 81 45 453 9222 Yokohama City Japan International Sales Office Locations Bioscience Technologies Thermo Electron Corporation 866 9 THERMO 866 984 3766 Molecular Biology info molbio thermo com Sample Preparation info sampleprep thermo com New Labs newlabs thermo com Services services biosciencetech thermo com Laboratory Pipetting and ...

Отзывы: