INSTALLATION 

 
 

Note:   This installation procedure is for guidance only, and the installer should verify its 
suitability. Make sure that the solar/boiler system is physically installed, manually tested, and is 
ready for controlled operation. 

 

 

 
 
he following safety precautions are strongly recommended: 

1.  Before attempting to install and operate the unit read this instruction manual carefully. 

2.  Only suitably qualified personnel should carry out installation and any maintenance required. 

3.  It is recommended that the unit be connected to the power supply via a suitably 6 amps 

isolating switch. 

4. 

WARNING: When the unit is connected to the 115-volt power supply and the cover is 
opened, high voltage circuits will be exposed. 

  Therefore, when installing the unit ensure 

all required connections are made and the cover is attached to the controller box before 
turning the power on.  Ensure that all the connections are secure.  If any maintenance work is 
required ensure that the unit is isolated from the power supply before removing the cover.  

Never leave the unit unattended if the cover has been removed and the power supply 
is connected.

 

5.  Do not exceed unit ratings of 2.15 amps (1/6 HP or 245 Watts pump). 

6.  It is advisable to route power cables away from sensor cables. 

 

 

 

 

ensor installation:  

Temperature

 

sensors may be installed in fluid lines by mounting in a 

tee or strapping it to the piping directly. 

 

For the system to function correctly, it is very 

important that the sensors are located and installed properly. Make absolutely sure that they are 
pushed completely into the optional sensor pockets (Thermowell is not supplied). Sensors must 
be well insulated in order to prevent them from being infl uenced by the ambient temperature. 

 

When used outdoors, no water should be allowed to get into the immersion sleeves (lasting 
impedance change). Generally, sensors should not be exposed to moisture (e.g. condensation) 
as this can diffuse through the cast resin and damage the sensor. Heating at approx. 195 °F for 
one hour may possibly save the sensor. 

 

When sensors are used in open loops or swimming pools, make absolutely sure that immersion 
sleeves (sensor pockets) are corrosion-resistant.

 

Содержание USDT 2005

Страница 1: ...l unit has the following functions 2 inputs for temperature sensors Suitable for sensors of type Thermistor and PT1000 Adjustable 70 o F to 210 o F overheating protection Adjustable 4 o F to 24 o F temperature difference delta T Manual override of pump for system testing Symbolic display of all parameters Indications of current state of pump System status and diagnostic displays Collector sensor s...

Страница 2: ...T to avoid pump cycling The pump A1 runs only when the temperature at the collector sensor location S1 is higher than the return temperature at location S2 by at least T The pump stops if T is less than the preset value or the if the temperature at location S2 storage tank has reached the TMAX A1 ON only when S1 S2 diff S2 max Boiler Control L Mode The User can switch USDT 2005 to operate a boiler...

Страница 3: ...med under voltage Switch Positions S K Solar systems with KTY 2000 ohm sensors S P Solar systems with PT 1000 1000 ohm sensors L K Boiler control with KTY 2000 ohm sensors L P Boiler control with PT 1000 1000 ohm sensors The impedance characteristics of sensors temperature dependencies are represented in the following table T 0 10 20 25 30 40 50 60 70 80 90 100 C R KTY 1630 1772 1922 2000 2080 224...

Страница 4: ...om the power supply before removing the cover Never leave the unit unattended if the cover has been removed and the power supply is connected 5 Do not exceed unit ratings of 2 15 amps 1 6 HP or 245 Watts pump 6 It is advisable to route power cables away from sensor cables ensor installation Temperature sensors may be installed in fluid lines by mounting in a tee or strapping it to the piping direc...

Страница 5: ...0 ft A connection between the sensor and extension can be established as follows Cut supplied heat shrinkable tubing to desired length about Slide tubing over one end of wire to be sliced after removing enough outer insulation to accept the tubing Then splice wire and slide tubing over the splice Heat gently all around until tubing shrinks tight Slide larger tubing about over the entire completed ...

Страница 6: ...erly grounded Flexible wires 18 3 AWG gauge conductor simplify connection to the terminals The power terminal block will accommodate wire sizes to 14 AWG All other connections should be secured and adequately tightened as loose power connections will over heat and may cause fire NOTE 3 It is important that the specified output loads 245 Watts are not exceeded Where these loads expect to exceed ext...