Section 7  

Replacement Parts

Model Type . . . . . . . . . . . . . . . . . . . . . . . . . . .D0800
Product Name  . . . . . . . . . . . . . . . .Bantam Deionizer
Series Number  . . . . . . . . . . . . . . . . . . . . . . . . . . .494

Deionizer      7-1

Thermo Scientific

Key 

Part # (Qty.)

Description

15847 

Elbow, 1/8" NPT x 1/4" tube

15570BI

Cell, BD-1

06411 

O-ring

15482BI

Ring, retaining

06419 

O-ring

15477BI

Valve, brass, 1/4" OD x 1/8" NPT

21538 (115V)

Meter

15597 

Cartridge holder

15896 

Nipple

10 

15502 

Lower Tightening Wheel

11 

05302 

Tee

D0803

Cartridge, high capacity

D0760

Cartridge, anion removal

D0815

Cartridge, cation removal

D0809

Cartridge, Ultrapure

D0813

Cartridge, organic removal

D0832

Cartridge, Ultrapure & organic removal

Содержание Thermo Scientific 494 Series

Страница 1: ...Scientific Bantam Deionizer Type D0800 Series 494 Operating Manual and Parts List 60119 Rev 0 _________________________________________________________________________________ Part of Thermo Fisher Scientific ...

Страница 2: ...ic MANUAL NUMBER 60119 7007107 0 6 4 10 Transfer to Marietta was 60119 3 12 08 ccs REV ECR ECN DATE DESCRIPTION By Preface Deionizer i Models covered in this manual Model number Voltage D0800 7107 120V D0805 7108 240V ...

Страница 3: ...tments and maintenance must be performed by qualified service personnel s Material in this manual is for information purposes only The contents and the product it describes are subject to change without notice Thermo Fisher Scientific makes no representations or warranties with respect to this manual In no event shall Thermo be held liable for any damages direct or incidental arising out of or rel...

Страница 4: ...pment that has been put on the market after 13 August 2005 This product is required to comply with the European Union s Waste Electrical Electronic Equipment WEEE Directive 2002 96 EC It is marked with the WEEE symbol Thermo Fisher Scientific has contracted with one or more recycling disposal companies in each EU Member State European Country and this product should be disposed of or recycled thro...

Страница 5: ...rts or provide you with on site service We can also provide you with a quotation on our Extended Warranty for your Thermo Scientific products Whatever Thermo Scientific products you need or use we will be happy to discuss your applications If you are experiencing technical problems working together we will help you locate the problem and chances are correct it yourself over the telephone without a...

Страница 6: ...ice Connections 4 1 Mounting 4 1 Choosing a Site 4 1 Elbow Tubing Assembly 4 2 Plumbing Service Connections 4 2 Cartridge Installation 4 3 Operation 5 1 Purity Meter Operation 5 1 Maintenance and Servicing 6 1 Calibration 6 1 Exploded View 6 2 Replacement Parts 7 1 Ordering Procedures 7 2 Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 ...

Страница 7: ......

Страница 8: ... install it in conformance with local electrical codes For safe operation pay attention to Notes Cautions and Warnings throughout the manual Warnings To avoid electrical shock always 1 Use a properly grounded electrical outlet of correct voltage and current handling capacity 2 Disconnect from the power supply prior to maintenance and servicing To avoid personal injury 1 Do not use in the presence ...

Страница 9: ......

Страница 10: ... Ensure that maximum flow rate is not exceeded the outlet is open to atmosphere and there are no tubing restrictions 2 Provided with 1 7 m 5 1 2 electrical cord and plug SI Units English Maximum flow rate 38 LPH1 10 GPH1 Temperature range 4 49 C 40 120 F Exchange capacity see below see below Plumbing service connections Inlet 1 4 OD tubing Outlet 1 4 OD tubing Drain 1 4 OD tubing Overall dimension...

Страница 11: ......

Страница 12: ...s to the acid form resulting in a product water that is low in pH ideal for precious metal or isotope recovery Strong Cation Exchange 3170 grains D0815 High Capacity Removes ionized impurities produces a larger quantity of water than that of the Ultrapure D0809 however at a lower resistivity Two Bed Ion Exchange 1760 grains D0803 Organic Removal Removes organics and chlorine Activated Carbon 5000 ...

Страница 13: ......

Страница 14: ...et opening 2 Install a customer supplied 3 8 NPT x 1 8 NPT brass bushing in the faucet opening The 1 8 NPT portion of the brass bushing is used to connect the 1 8 NPT x 1 4 OD straight connector provided to connect the Deionizer inlet to the raw water supply If the raw water supply service connection is not 3 8 NPT use another brass fitting as required Note It is suggested that the Deionizer inlet...

Страница 15: ...the remaining tubing to the plumbing service connection marked drain and extend the tubing into the sink to allow the holder to be drained in an unrestricted manner Caution Do not restrict the tubing and run the tubing in an upward direction from the top of the unit Any restriction on the outlet can result in a cartridge bursting and flooding s Assembling the tubing and polypropylene elbow is acco...

Страница 16: ...osition the large opening toward the bottom The lower tightening wheel should be turned down to allow the cartridge to be centered between the top and bottom o ring 3 Turn the lower tightening wheel until the cartridge seats against the top o ring Caution Do not apply a wrench to the nut the nut should be hand tightened only enough to prevent leakage Caution Do not over tighten the tightening whee...

Страница 17: ......

Страница 18: ...artridge Technical Characteristics Caution Do not exceed a flow rate of 38 LPH 10 GPH Leakage will occur if this flow is exceeded s Operate the Direct Reading Meter by setting the on off switch to the on position When the purity meter drops below the acceptable minimum purity or when the purity meter needle registers in the 0 05 to 0 025 megohm red range the cartridge should be replaced The meter ...

Страница 19: ......

Страница 20: ...h to the off position 2 Check the zero alignment of the meter needle to the meter scale If required rotate the zero adjustment screw until the meter needle is aligned with the line indicating the beginning of the meter scale The zero adjustment screw is located on the face of the meter below the scales 3 To calibrate the meter further connect a known resistance across the cell terminals A 50 000 o...

Страница 21: ...6 2 Deionizer Thermo Scientific Section 6 Maintenance and Servicing Figure 6 1 Exploded View ...

Страница 22: ...ll BD 1 3 06411 O ring 4 15482BI Ring retaining 5 06419 O ring 6 15477BI Valve brass 1 4 OD x 1 8 NPT 7 21538 115V Meter 8 15597 Cartridge holder 9 15896 Nipple 10 15502 Lower Tightening Wheel 11 05302 Tee D0803 Cartridge high capacity D0760 Cartridge anion removal D0815 Cartridge cation removal D0809 Cartridge Ultrapure D0813 Cartridge organic removal D0832 Cartridge Ultrapure organic removal ...

Страница 23: ...ed herein may be ordered from the Thermo Scientific dealer from whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed check first with your dealer If the dealer cannot process your request then contact our Technical Services Department Prior to returning any materials please contact our Technical Services Department for a Return Mate...

Страница 24: ...Thermo Scientific 401 Millcreek Road Marietta Ohio 45750 United States www thermofisher com ...