Orion Star A215 Benchtop pH/Conductivity Meters

8

Setup Menu Overview

pH Channel

COND Channel

Settings

Log View

Diagnostics

Method

Mode & Settings

t

 Measure Mode

t

Read Type

t

Resolution

t

Buffer Group

t

Stability

t

Averaging

t

Alarm Settings 

Temperature

t

Manual Temp Value

t

Temperature Unit

t

Temperature 

Calibration

t

 Temperature Input

Method

Mode & Settings

t

 Measure Mode

t

Read Type

t

Cell K

t

Stability

t

Averaging

t

Ref Temp

t

Temp Comp.

t

Temp Coeff

t

Alarm Settings

 

Temperature

t

Manual Temp Value

t

Temperature Unit

t

Temperature 

Calibration

t

Temperature Input

t

 Export Data

t

 Data Log

t

 Date / Time

t

 Language

t

 Key Press Beep

t

 Alarm Beep

t

 Stirrer

t

 Contrast

t

 Auto Shut Off

t

 User ID

t

 Sample ID

t

 Data Log

t

 Calibration 

Log

t

 Meter Self Test

t

 Factory Reset

t

 About Meter

Содержание Orion Star A215

Страница 1: ...ding to the directions in the electrode user guide 2 Connect the appropriate items as labeled on the meter and as shown in the gure to the right Electrode Arm The electrode arm can be attached to eith...

Страница 2: ...t stability M 100 Indicates a method is in use and the number of the method being used pH Indicates the type of measurement and determines the type of calibration that will be performed ready Speci es...

Страница 3: ...n When the meter is on press and quickly release to turn the display backlight on or off or hold down to turn the meter off In the measurement mode press to take a measurement In the setup calibration...

Страница 4: ...t to accept the displayed value b Press f3 edit to access the numeric entry screen and edit the value i Press or to highlight a number decimal point or negative sign press f3 enter to select the highl...

Страница 5: ...and place into the standard 3 When the conductivity cell and standard are ready press f3 start 4 Wait for the conductivity value on the meter to stabilize and stop ashing and perform one of the follow...

Страница 6: ...data log is enabled in the setup menu 1 Rinse the pH electrode conductivity cell and any other electrodes in use with distilled water blot dry with a lint free tissue and place into the sample 2 If th...

Страница 7: ...bmenus a To select a value from a list of options press or to highlight the desired value and press f3 select to set the value b To enter a numeric value use the numeric entry screen i Select the valu...

Страница 8: ...t Temperature Calibration t Temperature Input Method Mode Settings t Measure Mode t Read Type t Cell K t Stability t Averaging t Ref Temp t Temp Comp t Temp Coeff t Alarm Settings Temperature t Manua...

Страница 9: ...usethe numericentryscreentochangethevaluesandpressf1 back whenthetimeintervaliscorrect 6 Press to return to the measurement mode pH Buffer Group Selection The selected buffer group allows for the auto...

Страница 10: ...tycell a Press or to highlight a number or decimal point press f3 enter to select the highlighted item and repeat until the nominal cell constant value is shown b Press f2 done to exit the numeric ent...

Страница 11: ...or EP and press f3 select 6 Press to return to the measurement mode Viewing the Calibration Log 1 In the measurement mode press 2 Press or to highlight Calibration Log and press f2 accept 3 Press or...

Страница 12: ...Tel 81 045 453 9175 wai asia thermo sher com Australia Tel 613 9757 4300 in Australia 1300 735 296 InfoWaterAU thermo sher com 9 0 0 1 2 0 0 8 68X576505 RevA 0811 Viewing the Data Log 1 In the measure...

Отзывы: