background image

APPENDIX A   

Troubleshooting .................................................... 26

APPENDIX B   

Repair and maintenance .......................................... 28

Encountering Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Replace the fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

APPENDIX C   

Electrical parameters for electrophoresis ........................ 30

Ohm’s Law and Joule’s Law . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

APPENDIX D   

General safety ...................................................... 31

Instrument safety  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Avoid electrical shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Avoid damage to the instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Explanation of symbols and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Symbols and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Product regulatory compliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Federal Communications Commission  Advisory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Environmental design compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

APPENDIX E   

Product specifications ............................................. 34

Product specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

APPENDIX F   

Documentation and support ...................................... 36

Customer and technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Limited product warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Contents

4

PowerEase

 Touch 600W Power Supply User Guide

Содержание invitrogen PowerEase Touch

Страница 1: ...Not for use in diagnostic procedures PowerEase Touch 600W Power Supply USER GUIDE Catalog Number PS0600 115 VAC PS0601 230 VAC PS0602 230 VAC Australia and PS0603 230 VAC China Publication Number MAN...

Страница 2: ...FOR SPECIAL INCIDENTAL INDIRECT PUNITIVE MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT INCLUDING YOUR USE OF IT Revision history Pub No MAN0025330 Revision Date De...

Страница 3: ...onstant Power 13 Custom methods 13 Select a pre programed method 14 Manage methods 16 Save a method 16 Edit a method 17 Delete a method 18 Change the name of a saved method 18 Add a step 19 Delete a s...

Страница 4: ...trument safety 31 Avoid electrical shock 31 Avoid damage to the instrument 31 Explanation of symbols and warnings 32 Symbols and warnings 32 Product regulatory compliance 33 Federal Communications Com...

Страница 5: ...o screen viewing angle Sturdy polyurethane feet and stackable housing design allow stacking of power supplies Running modes include Constant Voltage Constant Power or Constant Current Programming capa...

Страница 6: ...jacks Polyurethane feet Pop up feet Figure 1 Front view of PowerEase Touch 600W Power Supply Figure 2 Rear view of PowerEase Touch 600W Power Supply Chapter 1 Product information Product description...

Страница 7: ...e of the power cords appear similar users should utilize the cord approved for their country region North America customers should use the Type B power cord Japan customers should use the JIS 8303 pow...

Страница 8: ...s on electrical plug PowerEase Touch 600W Power Supply 1 each Extra Fuse 1 each Type I Power Cord 1 each NSW 18392 USB Cover 1 each Quick Reference Card 1 each Certificate of Performance 1 each Table...

Страница 9: ...the run Limiting the voltage allows for an improving margin of safety over time because the current and power decrease through the run Also the same voltage can be used regardless of the number or th...

Страница 10: ...e step and multi step methods Up to 100 user defined methods can be saved up to 20 steps can be saved for each multi step method This power supply is also equipped with several pre programed gel elect...

Страница 11: ...n will appear on the Home screen when the power supply is switched on for the first time or it if is switched on after running an unsaved custom method see below The Last run option will appear on the...

Страница 12: ...creen to bring up the Run parameter edit screen Default maximum values are 500 V 3000 mA and 600 W Note When using constant voltage or constant power it is recommended that the maximum default setting...

Страница 13: ...may cause the voltage to increase to the maximum capacity of the power supply This may lead to local overheating and damage to the electrophoresis cell or create unsafe conditions Note When operating...

Страница 14: ...rophoresing midi gels sold by Thermo Fisher Scientific Inc Selecting Western Southern blotting brings up a list of preloaded methods for transferring gels to western blots 3 To view method options not...

Страница 15: ...n time for your gel may be slightly different than the default value given by the pre programed method The default run times shown in mini gel pre programed methods assume the use of the Invitrogen Mi...

Страница 16: ...creen see Figure 9 2 Save an edited pre programed method by touching Edit 3 Touch the Name of method field in the Save As screen to bring up a keyboard that will allow entry of the method name Method...

Страница 17: ...s in a method touch the data field for the parameter you wish to change Selecting a run parameter will bring up its Edit screen 2 Enter the parameter value required then press Enter Note Do not save c...

Страница 18: ...ist of displayed methods then press Delete If several methods have been saved swipe up as you would with a smart phone to scroll down the list Figure 10 Managing saved methods Change the name of a sav...

Страница 19: ...previous step or right arrow next step 3 When all of the steps have been entered touch Start run to initiate the run To previous step To next step Figure 11 Method step number location Delete a step 1...

Страница 20: ...ings screen Run screen features Method name The name of the method will be displayed at the top of the screen If the method is an un named custom method the name displayed will be the method type Cons...

Страница 21: ...rt back to the set method constant parameter 200 V in this case and the crossover icon will no longer be displayed Figure 12 shows a run with crossover to mA and current limited to 40 mA For additiona...

Страница 22: ...13 To save the method touch Save run This will bring up the Save As screen Figure 9 Touching the right arrow will display a summary of steps used for the method If a pre programed or saved custom meth...

Страница 23: ...vigation on page 11 To view Settings options not available on the first screen gently swipe up with your finger as you would with a smart phone Options available from the settings menu are About Last...

Страница 24: ...brightness Press to increase brightness or to reduce brightness Volume Allows adjustment of beeper volume Press to increase volume or to reduce volume Sleep mode Allows adjustment of the inactivity ti...

Страница 25: ...FAT32 format and have a maximum capacity of 32 GB 2 On the Settings screen touch Software update see Figure 14 The power supply will search for update files on the USB drive This will take several sec...

Страница 26: ...uffer levels then press Restart to restart the run Operation stops with alarm Display shows Over Voltage Output voltage was too high and the power supply stops the output Verify cable connections Veri...

Страница 27: ...run or Restart to restart the run Excessive buffer evaporation Ensure electrophoresis settings and buffer concentration is correct Ensure wire connections are intact Press Resume to continue the run o...

Страница 28: ...fuses contact support see Appendix F Documentation and support 1 Turn off the power switch and detach the power cord at the rear of the power supply unit 2 Open the fuse compartment located inside th...

Страница 29: ...p the cover closed and re attach the power cord Figure 16 Rearview of PowerEase Touch 600W Power Supply Appendix B Repair and maintenance Replace the fuse B PowerEase Touch 600W Power Supply User Guid...

Страница 30: ...ced by the slower moving less conductive glycine glycinate ions from the running buffer as the gel runs As a result the resistance of the gel increases as the chloride glycine front moves down the gel...

Страница 31: ...atus ALWAYS make sure that hands work area and instruments are clean and dry before making any connections or operating the power supply ALWAYS connect the power supply to a properly grounded AC outle...

Страница 32: ...e disposal options Ne pas liminer ce produit avec les d chets usuels non soumis au tri s lectif CAUTION Pour minimiser les consequences n gatives sur l environnement la suite de l limination de d chet...

Страница 33: ...imits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequenc...

Страница 34: ...voltage Operating Modes Constant Voltage Constant Current Constant Power 1 V step 1 mA step 1 watt step Timer Up to 999 min per step Crossover Automatic Display type Backlit TFT LCD Graphic type Disp...

Страница 35: ...x D x H Operating temperature 0 C 40 C Environmental conditions 95 RH non condensing 75 KPa 106 KPa altitude not to exceed 2 000 meters Weight 2 8 kg Certifications CE cTUVus RCM China RoHs Warranty 1...

Страница 36: ...protocols Certificates of Analysis Safety Data Sheets SDSs also known as MSDSs Note For SDSs for reagents and chemicals from other manufacturers contact the manufacturer Limited product warranty Life...

Страница 37: ......

Страница 38: ...Touch 600W Power Supply_UG_MAN0025330 v2 GUID F6684776 495C 4204 A06E 1B4D721CE663 2021 05 18 17 35 23 en 16 19 29 664 01 00 thermofisher com support thermofisher com askaquestion thermofisher com 20...

Отзывы: