3.1 Specifications

Speed Range......................................................150 to 1200rpm
Orbit Diameter.................................................................

2.5mm

Speed Accuracy......................±1% of set speed up to 299rpm
                                                                  

±

2%

 

300 to 1200rpm

Maximum Load……………………………………...........1kg @1200rpm/
                                       4kg @

400rpm(accessory included)

Maximum Capacity(Centered on tray)……96-well Microplate
                                       4 or 6 depends on different platforms

Timing Range…………..……............................0, 1min. 99h59min.

Overall Dimensions........................................383×260×145mm
Tray Dimensions...............................................275×235×14mm
Packaging Dimensions.................................487×387×264mm

Net Weight.............................................................12.8Kg(28.2lb)
Gross Weight............................................................15Kg(33.1lb)

Requirement................................AC100-240V, 50/60Hz, 72VA

Certification..............................RoHS, WEEE, cCSAus, CE Mark

Application Environmental Conditions: indoor use
Temperature....................................................................5 to 40

Altitude...........................................................................

2,000 m

Humidity...................................................................... 20% to 85%

                                                                  

Storage Environmental Conditions
Temperature....................................................................0 to 60

Altitude...........................................................................

2,000 m

Humidity.......................................20% to 90%, non-condensing

 

~

3.2 Environmental Conditions

3.3 Safety Instructions

Rotation Speed

Load

Time

Size

Weight

Power Supply

Others

Please read the entire instruction manual 
before operating the Digital Microplate 
Shaker.

Digital 

Mircopalte Shaker 

DO NOT 

immerse the unit for 

cleaning.

DO NOT 

operate the unit if it shows

WARNING DO NOT

 use the 

in a hazardous 

atmosphere or with hazardous 
materials for which the unit was 
not designed.  Also, the user 
should be aware that the 
protection provided by the 
equipment may be impaired if 
accessories used are no provided 
or recommended by the 
manufacturer, or are used in a 
manner not specified by the 
manufacturer.

CAUTION !

 To avoid electrical 

shock, completely cut off power to 
the unit by disconnecting the 
power cord from the unit or unplug 
from the wall outlet. Disconnect 
unit from the power supply prior to 
maintenance and service. Any 
spills should be removed promptly. 
Bio hazard spills should be cleaned 
using approved liquid promptly. 
Solvent spills are a fire hazard.
Stop the unit immediately, and DO 
NOT operate until clean up is 
complete and vapors have 
dissipated.

signs of electrical or mechanical 
damage.

Position of Loads

Please place loads symmetrically during 
operation.

Symmetrical placement

5      

 |  

Section 3  Overview

Digital Microplate Shaker       6

Содержание 88882005

Страница 1: ...hermofisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca For Research Use Only Not for use in diagnostic procedures 2019 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified Operating Manual Revision A 09 03 2019 ...

Страница 2: ...Overview Specifications Environmental Conditions Safety Instructions Capacity and Speed Section 4 Operation Control Panel Installation Settings Accessory Installation Section 5 Safety Tips and Maintenance Section 6 Troubleshooting Section 7 Optional Accessories Section 8 Warranty Information Contents 1 2 3 3 4 4 5 5 5 6 7 8 8 9 9 10 11 12 13 15 ...

Страница 3: ...g can happen Do not assemble repair modify on your own The product may not work well and electric shock is possible with changes in the efficiency of the product Also this will void the warranty Indicates a hazardous situation which if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coating and...

Страница 4: ...it Then unpack the unit Check carefully to see if there were damages incurred during transit After unpacking check that all unit parts and accessories are as listed below Contact us or the agent from which you purchased the unit if any components were omitted 3 Inspection Section 2 and Installation Screw Driver 1 1 12 12 Tray 96 Microplate Clamp 6 Installed well M3 6 Screw Installed Main Body Powe...

Страница 5: ... operating the Digital Microplate Shaker Digital Mircopalte Shaker DO NOT immerse the unit for cleaning DO NOT operate the unit if it shows WARNING DO NOT use the in a hazardous atmosphere or with hazardous materials for which the unit was not designed Also the user should be aware that the protection provided by the equipment may be impaired if accessories used are no provided or recommended by t...

Страница 6: ... Speed display window The window displays set speed when the instrument is in standby or current speed when the instrument is running Time display window The window displays cumulative time in continuous mode or remaining time in timer mode Time setting buttons UP DOWN arrow buttons are used to increase decrease the set time of the instrument Speed setting buttons UP DOWN arrow buttons are used to...

Страница 7: ...ital Microplate Shaker 10 4 2 Installation 1 Connect all the components according to the figures shown on page 4 of this manual Use grounded power outlet 2 Press the power switch I side and switch on the instrument 4 3 Settings Time Settings 1 Continuous mode Press the or arrow button below the Time display window When the number shown on the Time display window starts flashing press arrow button ...

Страница 8: ...urface of the instrument Place the instrument in a ventilated and dry environment for 24 hours before reuse If the instrument is not functioning after drying for 24 hours please contact the manufacturer Warning Disassembling Assembling without a qualified professional s guidance may cause malfunctioning of the instrument Section 5 Safety Tips and Maintenance Section 6 Troubleshooting Error Cannot ...

Страница 9: ...er Adaptor w AUS CN plug General Power Adaptor w EU plug General Power Adaptor w UK plug Platform Large Assemble For 6 x Microplates 96 well Microplate clamp Digital Microplate Shaker 14 88882130 88882131 88882132 Screw GB T819 1 M4 8 Platform installation Screw GB T819 1 M5 10 Tube rack installation Screw GB T9074 4 M3 6 96 well Microplate clamp installation Dimensions 292x275x14mm 292x275x25mm 1...

Страница 10: ...the component part beyond the original warranty period The Technical Services Department must give prior approval for return of any components or equipment At Thermo s option all non conforming parts must be returned to Thermo Fisher Scientific postage paid and replacement parts are shipped FOB destination THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLI...

Отзывы: