Section 1  Important Information

Ignoring the following warnings could 
cause serious injuries or even fatal 
accidents. 

Check the voltage, phase and capacity of 
power supply on the ID plate before 
installation. Connect properly. 

Power supply must be properly 
grounded. Abnormal grounded 
connection causes serious damage. 
Grounded connection must not be on the 
water pipe and gas pipe. 

Use provided power cord. Power cord: 
Wall outlet with grounded terminal 
power cord 250V 10A

Do not install the product in a place that 
gas could leak. Do not use in a place that 
has industrial oil smoke or metallic dust. 
It causes fire or electric shock. Do not 
use the machine near to places where 
explosion could happen due to organic 
evaporating gases. 

Explosive materials: acid, esther, nitro 
compound. 

Inflammable materials: salt peroxides, 
inorganic peroxide, salt acids. 

Check equipment for permissible 
environmental conditions when using 
inside of Temperature and Humidity 
Chamber or Incubator. It can be the 
cause of fire or trouble by stirrer 
electricity, electronic, and damage of 
motor. 

Rocker’s permissible environmental 
condition. Temperature 5°C to 40°C, 
Maximum relative humidity 80%. 

Unplug if there is a strange sound, smell 
and/or smoke from the product. Stop

operating and request the service. 

Keep out of the direct sunlight. It may 
influence product life and proper 
operation. 

Do not use the machine at places where 
moisture is high and flooding can 
happen. 

Do not assemble, repair, modify on your 
own. The product may not work well and 
electric shock is possible with changes 
in the efficiency of the product. Also this 
will void the warranty.

Indicates a hazardous situation which, if 
not avoided, may result in minor or 
moderate injury. 

Do not put heavy things on the power 
cord. Do not put the machine on the 
cord. It may take off the wire coating and 
cause electric shock or fire.

 Do not touch it with wet hands and 
place the main plug correctly. It could 
cause the electric shock or injuries. 

Installing power outlet near instrument 
may be convenient

Do not install the stirrer near machinery 
generating high frequency noise. Avoid 
installation close to high frequency- 
welding machine, sewing machine, or 
mass SCR controller. 

Do not inject any liquid and inflammable 
things inside of product.

Do not pour water or put liquid on the 
top of the product when cleaning. 
Disconnect the main power immediately 
and request the service if water may be 
in the product.  

Do not let the product take any strong 
shock or vibration. It could cause 
abnormal operation or trouble. It may 
deteriorate the ability of the product 
operation and not obtain correct results. 

Do not sprinkle insecticide or flammable 
spray on the product. Use smooth 
cloths. Cleaning with solvent can cause 
fire and deformity. 

Power off while product cleaning. It may 
cause electric shock or fire. 

Do not drop or allow the machine to fall. 
It will cause wrong operation and 
malfunction. 

Disposing of Product

Dispose the unit with separating plastic 
mold, and motor.

 

1      

 |  

 

Section 1  Important Information

Digital Rocker      2

Содержание 88882001

Страница 1: ...fisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca For Research Use Only Not for use in diagnostic procedures 2019 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified Operating Manual Revision A 09 03 2019 ...

Страница 2: ... Section 3 Overview Specifications Environmental Conditions Safety Instructions Loads Angle and Speed Section 4 Operation Control Panel Installation Settings Section 5 Safety Tips and Maintenance Section 6 Troubleshooting Section 7 Optional Accessories Section 8 Warranty Information Contents 1 2 3 3 4 4 5 5 5 6 7 8 8 9 9 12 13 14 15 ...

Страница 3: ...looding can happen Do not assemble repair modify on your own The product may not work well and electric shock is possible with changes in the efficiency of the product Also this will void the warranty Indicates a hazardous situation which if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coati...

Страница 4: ...heck carefully to see if there were damages incurred during transit After unpacking check that all unit parts and accessories are as listed below Contact us or the agent from which you purchased the unit if any components were omitted 3 Section 2 Inspection and Installation Digital Rocker 4 General Power Adaptor US Plug CN Plug EU Plug UK Plug Catalog Number 88882001 1 10 N A N A N A Digital Rocke...

Страница 5: ...leaning DO NOT operate the unit if it shows signs of electrical or mechanical damage WARNING DO NOT use the in a hazardous atmosphere or with hazardous materials for which the unit was not designed Also the user should be aware that the protection provided by the equipment may be impaired if accessories used are no provided or recommended by the manufacturer or are used in a manner not specified b...

Страница 6: ... Time Tilt display window The window displays cumulative time in continuous mode or remaining time in timer mode The range of time displayed is 0s to 9999 minutes Time indicator The light is on when the instrument is running in Timer Mode Tilt indicator The light is on when the instrument is in Tilt Adjustment Mode Mode button Switch modes between time and Tilt settings Time Tilt setting buttons U...

Страница 7: ...strument according to the storage guide Alarm System Err1 If running speed does not match the setting speed the instrument will have a three time reboot and after the three reboots failed there will be a buzzer and then Err1 will be displayed in the Speed display window End of timer The instrument buzzing alarm the End is displayed in the Speed window When the instrument alarms press any key the i...

Страница 8: ... immediately clean up the liquid at the surface of the instrument Place the instrument in a ventilated and dry environment for 24 hours before reuse If the instrument is not functioning after drying for 24 hours please contact the manufacturer Warning Disassembling Assembling without a qualified professional s guidance may cause malfunctioning of the instrument 11 Section 5 Safety Tips and Mainten...

Страница 9: ...epairs Expendable items glass filters and gaskets are excluded from this warranty Replacement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the component part beyond the original warranty period The Technical Services Department must give prior approval for return of any components or equipment At Thermo s option all non ...

Отзывы: