background image

Thermo Scientific

75003623 CLINIConic 30

 

x

 

15

B-1

B

Chemical Compatibility Chart  

CHEMICAL

MA

TER

IA

L

ALUMIN

I

UM

ANODIC COATING for

 AL

UMIN

I

UM

BU

NA

 N

CE

LL

UL

OSE A

C

ET

A

TE

 BUTYRA

TE

POL

YURETH

ANE ROTO

R P

A

INT

CO

MPOSIT

E Car

bon

 Fi

ber

/Epo

xy

DEL

RIN

®

ETHYL

ENE P

R

O

PYLE

N

E

GLA

S

S

N

EOPRENE

NO

RY

L

®

NY

LO

N

PET

*

, PO

LYCL

EAR

®

,C

LEAR

CRIM

P

®

CCC

LEAR

CRIM

P

®

POL

YA

LL

O

ME

R

POL

YCA

R

BONA

TE

POL

YESTER, G

LA

S

S TH

ERMOSET

POL

YTHE

RM

IDE

POL

YR

THYL

ENE

POL

YPROPYL

ENE

POL

YSU

LF

O

NE

POL

YV

IN

YL CHLORIDE

RU

LON

 A

®

, TE

FL

ON

®

SI

LI

C

O

N

E RU

BB

ER

S

TAI

N

LES

S ST

EE

L

TIT

A

NIU

M

TYGON

®

VI

TO

N

®

2-mercaptoethanol

S

S

U -

S

M S

-

S

U S

S

U S

S

-

S

S

S

S

U S

S

S

S

S

S

Acetaldehyde

S

-

U U -

-

-

M -

U -

-

-

M U U U M M -

M S

U -

S

-

U

Acetone

M S

U U S

U M S

S

U U S

U S

U U U S

S

U U S

M M S

U U

Acetonitrile

S

S

U -

S

M S

-

S

S

U S

U M U U -

S

M U U S

S

S

S

U U

Alconox

®

U U S

-

S

S

S

-

S

S

S

S

S

S

M S

S

S

S

S

S

S

S

S

S

S

U

Allyl Alcohol

-

-

-

U -

-

S

-

-

-

-

S

-

S

S

M S

S

S

-

M S

-

-

S

-

-

Aluminum Chloride

U U S

S

S

S

U S

S

S

S

M S

S

S

S

-

S

S

S

S

S

M U U S

S

Formic Acid (100

 

%)

-

S

M U -

-

U -

-

-

-

U -

S

M U U S

S

-

U S

-

U S

-

U

Ammonium Acetate

S

S

U -

S

S

S

-

S

S

S

S

S

S

S

U -

S

S

S

S

S

S

S

S

S

S

Ammonium Carbonate

M S

U S

S

S

S

S

S

S

S

S

S

S

U U -

S

S

S

S

S

S

M S

S

S

Ammonium Hydroxide (10

 

%)

U U S

U S

S

M S

S

S

S

S

-

S

U M S

S

S

S

S

S

S

S

S

M S

Ammonium Hydroxide (28

 

%)

U U S

U S

U M S

S

S

S

S

U S

U M S

S

S

S

S

S

S

S

S

M S

Ammonium Hydroxide (conc.)

U U U U S

U M S

-

S

-

S

U S

U U S

S

S

-

M S

S

S

S

-

U

Ammonium Phosphate

U -

S

-

S

S

S

S

S

S

S

S

-

S

S

M -

S

S

S

S

S

S

M S

S

S

Ammonium Sulfate

U M S

-

S

S

U S

S

S

S

S

S

S

S

S

-

S

S

S

S

S

S

U S

S

U

Amyl Alcohol

S

-

M U -

-

S

S

-

M -

S

-

M S

S

S

S

M -

-

-

U -

S

-

M

Aniline

S

S

U U S

U S

M S

U U U U U U U -

S

M U U S

S

S

S

U S

Sodium Hydroxide (<1

 

%)

U -

M S

S

S

-

-

S

M S

S

-

S

M M S

S

S

S

S

S

M S

S

-

U

Sodium Hydroxide (10

 

%)

U -

M U -

-

U -

M M S

S

U S

U U S

S

S

S

S

S

M S

S

-

U

Barium Salts

M U S

-

S

S

S

S

S

S

S

S

S

S

S

M -

S

S

S

S

S

S

M S

S

S

Benzene

S

S

U U S

U M U S

U U S

U U U M U M U U U S

U U S

U S

Benzyl Alcohol

S

-

U U -

-

M M -

M -

S

U U U U U U U -

M S

M -

S

-

S

Boric Acid

U S

S

M S

S

U S

S

S

S

S

S

S

S

S

U S

S

S

S

S

S

S

S

S

S

Содержание 75003623

Страница 1: ...Visit us online to register your warranty thermofisher com labwarranty Thermo Scientific CLINIConic 30 x 15 Instruction Manual 50121050 d 07 2020...

Страница 2: ...WEEE Conformity This product is subject to the regulations of the EU Waste Electrical Electronic Equipment WEEE Directive 2012 19 EU It is marked by the following symbol...

Страница 3: ...Rotor Installation 3 2 Removing the Rotor 3 3 Chapter 4 Rotor Loading 4 1 Before a Run 4 2 Proper Loading 4 2 Improper Loading 4 2 Maximum Loading 4 3 Cycle Counter 4 4 Chapter 5 Maintenance and Care...

Страница 4: ......

Страница 5: ...resentative Precautions In order to ensure safe operation of the CLINIConic 30 x 15 the following general safety regulations must be followed Do not remove the magnet at the rotor bottom Do not use ro...

Страница 6: ...ace before operating the centrifuge Always balance the samples Maximum sample density at maximum speed 1 2 g ml This symbol refers to general hazards ATTENTION means that material damage could occur W...

Страница 7: ...Thermo Scientific 75003623 CLINIConic 30 x 15 1 1 1 Rotor Specifications Contents Technical Data on page 1 2...

Страница 8: ...perature of 23 C running time 60 minutes 9 9 aerosol tight no no permissible temperature range autoclavable C 121 121 Table 1 2 230 V 50 60 Hz refrigerated Centrifuge Multifuge X1 R Megafuge 16R Catal...

Страница 9: ...of 23 C running time 60 minutes 9 9 aerosol tight no no permissible temperature range autoclavable C 121 121 Table 1 4 120 V 60 Hz refrigerated Centrifuge Multifuge X1 R Megafuge 16R Catalog 75004251...

Страница 10: ...of 23 C running time 60 minutes 9 9 aerosol tight no no permissible temperature range autoclavable C 121 121 Table 1 6 230 V 50 60 Hz refrigerated Centrifuge Sorvall Legend X1R Sorvall ST 16R Catalog...

Страница 11: ...of 23 C running time 60 minutes 9 9 aerosol tight no no permissible temperature range autoclavable C 121 121 Table 1 8 120 V 60 Hz refrigerated Centrifuge Sorvall Legend X1R Sorvall ST 16R Catalog 750...

Страница 12: ...f 23 C running time 60 minutes 9 9 aerosol tight no no permissible temperature range autoclavable C 121 121 Table 1 10 100 V 50 60 Hz refrigerated Centrifuge Sorvall Legend X1R Sorvall ST 16R Catalog...

Страница 13: ...23 C running time 60 minutes 9 aerosol tight no permissible temperature range autoclavable C 121 Table 1 12 230 V 50 60 Hz refrigerated Centrifuge Thermo Scientific SL 16R Catalog 75004030 Weight emp...

Страница 14: ...23 C running time 60 minutes 9 aerosol tight no permissible temperature range autoclavable C 121 Table 1 14 120 V 60 Hz refrigerated Centrifuge Thermo Scientific SL 16R Catalog 75004031 Weight empty...

Страница 15: ...Thermo Scientific 75003623 CLINIConic 30 x 15 2 1 2 Accessories Contents Rotor data on page 2 1 Accessories on page 2 1...

Страница 16: ...2 Accessories 2 2 75003623 CLINIConic 30 x 15 Thermo Scientific...

Страница 17: ...Thermo Scientific 75003623 CLINIConic 30 x 15 3 1 3 AutoLock Contents Rotor Installation on page 3 2 Removing the Rotor on page 3 3...

Страница 18: ...he shaft The rotor clicks automatically into place 3 Check if the rotor is properly installed by lifting it slightly on the handle If the rotor can be pulled up then it must be reclamped to the shaft...

Страница 19: ...s against the green AutoLock key At the same time pull the rotor directly upwards with both hands and remove it from the motor shaft Make sure not to jam the rotor while doing this CAUTION Check that...

Страница 20: ......

Страница 21: ...o Scientific 75003623 CLINIConic 30 x 15 4 1 4 Rotor Loading Contents Before a run on page 4 2 Proper Loading on page 4 2 Improper Loading on page 4 2 Maximum loading on page 4 3 Cycle Counter on page...

Страница 22: ...haft and the AutoLock 4 Check the rotor s suitability using the Chemical Compatibility Chart on page B 1 5 Make sure the tubes or bottles do not touch the lid Proper Loading To ensure safe operation o...

Страница 23: ...two options available for centrifuging samples whose weight including adaptor exceeds the maximum permissible load Reduce the fill level Reduce the speed Use the table or formula below Recalculate th...

Страница 24: ...of cycles recommended for rotors and buckets The maximum number of cycles is given in Rotor Specifications on page 1 1 Service life examples WARNING Replace the rotor when the specified number of cycl...

Страница 25: ...INIConic 30 x 15 5 1 5 Maintenance and Care Contents Cleaning Intervals on page 5 2 Cleaning on page 5 2 Disinfection on page 5 3 Decontamination on page 5 4 Autoclaving on page 5 5 Service of Thermo...

Страница 26: ...f the parts Use only disinfectants with a pH of 6 8 Dry aluminum parts off with a soft cloth After cleaning treat the entire surface of aluminum parts with corrosion protection oil 70009824 Also treat...

Страница 27: ...rayer whenever possible so that all surfaces are covered evenly The rotor chamber and the rotor should be treated preferably with a neutral disinfectant A disinfectant spray would be most suitable for...

Страница 28: ...s with corrosion protection oil 70009824 Also treat the cavities with oil 12 Treat the bolt of the swing out rotor with bolt grease 75003786 Decontamination Decontaminate the centrifuge immediately wh...

Страница 29: ...ving 1 Before autoclaving clean rotor and accessories and described above 2 Place the rotor on a flat surface Rotors and adapters can be autoclaved at 121 C The maximum permissible autoclave cycle is...

Страница 30: ......

Страница 31: ...5 157 1100 8 5 14 0 115 189 1200 8 5 14 0 137 225 1300 8 5 14 0 161 265 1400 8 5 14 0 186 307 1500 8 5 14 0 214 352 1600 8 5 14 0 243 401 1700 8 5 14 0 275 452 1800 8 5 14 0 308 507 1900 8 5 14 0 343...

Страница 32: ...381 4000 8 5 14 0 1520 2504 4100 8 5 14 0 1597 2631 4200 8 5 14 0 1676 2761 4300 8 5 14 0 1757 2894 4400 8 5 14 0 1840 3030 4500 8 5 14 0 1924 3170 4600 8 5 14 0 2011 3312 4700 8 5 14 0 2099 3458 4800...

Страница 33: ...S S S S U S S S S M S S S S S S S S S M U U S S Formic Acid 100 S M U U U S M U U S S U S U S U Ammonium Acetate S S U S S S S S S S S S S U S S S S S S S S S S Ammonium Carbonate M S U S S S S S S S...

Страница 34: ...S S U S U S U S S S M S S S S S S Dimethylsulfoxide S S U U S S S S U S S U S U U S S U U S S S S U U Dioxane M S U U S S M M S U U S U M U U M M M U S S S S U U Ferric Chloride U U S M S M S S S S M...

Страница 35: ...Hydroxide conc U U M U M M S S U M U U U S M M U U U U Potassium Permanganate S S S S S S S S S U S S S M S M S U S S M S U S Calcium Chloride M U S S S S S S S S S S S S M S S S S S S S M S S S Calc...

Страница 36: ...S S S S S S M S S S S S S M S S S S S S S S S S Nickel Salts U S S S S S S S S S S S S S S S S S S M S S S Oils Petroleum S S S S U S S S S U U M S M U U S S S U S S S S Oils Other S S S M S S S S U S...

Страница 37: ...U U Toluene S S U U S S M U S U U S U U U S U M U U U S U S U U M Trichloroacetic Acid U U U S S U M S U S U U S M M S S U U S U U U M U Trichloroethane S U M U U S U U U U U U U U U S U S S Trichlor...

Страница 38: ...ists for materials under the stress of centrifugation when in doubt we recommend pretesting sample lots Key S Satisfactory M Moderate attack may be satisfactory for use in centrifuge depending on leng...

Страница 39: ...mical Compatibility Chart B 1 Cleaning 5 2 Cleaning agents 5 3 Cycle counter 4 4 D Decontamination 5 4 Disinfection 5 3 I Improper loading 4 2 M Maintenance 5 1 Maximum loading 4 3 P Precautions iii P...

Страница 40: ......

Страница 41: ...terms and pricing are subject to change Not all products are available in all countries Please consult your local sales representative for details Shown pictures within the manual are examples and ma...

Отзывы: