6  |   Before Use

Centrifuge GT 4 / 4R

Before Use

Before Setting Up

1. Check the centrifuge and the packaging for any shipping 

damage. 

Inform Fisher Scientific customer service immediately if 
any damage is discovered.

2. Remove the packaging. 

3. Check the order for completeness (refer to the section 

Scope of Supply

). If the order is incomplete, contact 

Fisher Scientific. 

Transporting the 
Centrifuge

Due to the weight (refer to the section 

Technical Data

), 

the centrifuge should be carried by several people. 

Always lift the centrifuge at both sides.

Figure 1. Lifting the centrifuge at both sides.

The centrifuge can be damaged by impacts.

Transport the centrifuge upright and if at all possible in its 
packaging.

Location

The centrifuge should only be operated indoors. 

The set-up location must fulfill the following requirements:

A safety zone of at least 30 cm must be maintained 
around the centrifuge. People and hazardous substances 
must be kept out of the safety zone while centrifuging.

The supporting structure must be stable and free of 
resonance, for example, a level laboratory bench.

The supporting structure must be suitable for horizontal 
setup of the centrifuge.

The centrifuge should not be exposed to heat and strong 
sunlight.

The set-up location must be well-ventilated at all times.

Aligning the Centrifuge

The horizontal alignment of the centrifuge must be checked 
every time after moving it to a different location. 

The supporting structure must be suitable for horizontal setup 
of the centrifuge.

WARNING: 

Always lift the centrifuge on both 

sides. Never lift the centrifuge by its front or the 
back panel.

Always remove the rotor before moving the 
centrifuge.

WARNING: 

UV rays reduce the stability of 

plastics.

Do not subject the centrifuge, rotors and plastic 
accessories to direct sunlight.

CAUTION: 

If the centrifuge is not leveled with 

ground, imbalances can occur and the centrifuge 
can be damaged.

Do not place anything under the feet to level the 
centrifuge.

Содержание 15828722

Страница 1: ...Instruction manual Fisherbrand GT4 Centrifuge Fisherbrand GT4R Centrifuge 50156444 b 11 2020 15858722 15848722 15838722 15828722 ...

Страница 2: ...oses only The contents and the product it describes are subject to change without notice Thermo Fisher Scientific makes no representations or warranties with respect to this manual In no event shall be held liable for any damages direct or incidental arising from or related to the use of this manual BIOShield Fiberlite HIGHConic Microliter MicroClick and Auto Lock All trademarks are the property o...

Страница 3: ...chnical Data 3 Directives Standards and Guidelines 4 Functions and Features 4 Mains Supply 5 Refrigerant 5 Rotor Selection 5 Before Use 6 Before Setting Up 6 Transporting the Centrifuge 6 Location 6 Aligning the Centrifuge 6 Mains Connection 7 Storage 7 Control Panel 8 Control Panel 8 Keys 8 Operation 9 Switch on Centrifuge 9 Lid Opening 9 ...

Страница 4: ...or 12 Aerosol Tight Rotors 13 Aligning the Centrifuge 13 System Menu 14 Description 15 Maintenance and Care 16 Cleaning Intervals 16 Cleaning 16 Disinfection 17 Decontamination 17 Autoclaving 18 Maintenance and Repair Services 18 Troubleshooting 19 Mechanical Emergency Door Release 19 Troubleshooting by User 20 When to Contact a Service Technician 23 Chemical Compatibility Chart 24 ...

Страница 5: ...afe operation of the Fisherbrand GT 4 4R Centrifuge the following general safety regulations must be followed Do not manipulate the safety devices The centrifuge should be operated by trained specialists only The centrifuge is to be used for its intended use only Plug the centrifuge only into sockets which have been properly grounded Do not move the centrifuge while it is running Do not lean on th...

Страница 6: ...entrifuge toxic or radioactive materials or any pathogenic micro organisms without suitable safety precautions When centrifuging microbiological samples from the Risk Group II according to the Bio safety Manual of the World Health Organization WHO aerosol tight biological seals have to be used For materials in a higher risk group extra safety measures have to be taken If toxins or pathogenic subst...

Страница 7: ...d a lock The lid of the centrifuge can only be opened while the centrifuge is switched ON and the rotor has come to a complete stop The centrifuge cannot be started until the lid is closed properly The integrated rotor detection systems ensure that no inadmissible speed settings can be preselected Electronic imbalance recognition Lid emergency release For emergencies only e g during power failures...

Страница 8: ... EC Electromagnetic Compatibility EMC 2011 65 EC RoHS Directive on the Restriction of the use of certain Hazardous Substances in electrical and electronic equipment EN 61010 1 2nd Edition IEC 61010 2 020 2nd Edition EN 61326 1 EN ISO 14971 EN ISO 9001 Component Function Description Features Structure Housing Galvanized steel chassis with armoured plating Chamber Stainless steel varnished steel Dri...

Страница 9: ... containers can be found in the corresponding rotor operating manuals For more information visit our website at fishersci com Type Mains Voltage Frequency Rated current Power consumption Equipment fuse Building fuse Refrigerated 230 V 50 60 Hz 10 5 A 1950 W 15 AT 16 AT Ventilated 230 V 50 60 Hz 11 A 1700 W 15 AT 16 AT Order no Centrifuge Refrigerant Quantity Pressure GWP CO2e 75004558 Fisherbrand ...

Страница 10: ...entrifuge People and hazardous substances must be kept out of the safety zone while centrifuging The supporting structure must be stable and free of resonance for example a level laboratory bench The supporting structure must be suitable for horizontal setup of the centrifuge The centrifuge should not be exposed to heat and strong sunlight The set up location must be well ventilated at all times A...

Страница 11: ...ds of your country 4 Make sure that the voltage and frequency correspond to the figures on the rating plate 5 Establish the connection to the power supply with the connecting cable Storage Before storing the centrifuge and the accessories it must be cleaned and if necessary disinfected and decontaminated Store the centrifuge in a clean dust free location Ensure to place the centrifuge on its feet ...

Страница 12: ... Temperature Acceleration curve Braking curve Bucket selection OPEN key Speed RCF value Key Display contents Start Normal start of the centrifuge Stop End run manually Open Lid Automatic release possible only when device is switched ON Emergency release refer to the section Mechanical Emergency Door Release Pulse By pressing the PULSE key the centrifuge starts immediately and accelerates up to the...

Страница 13: ...ved rotors for the Fisherbrand GT 4 4R Centrifuge are listed in section Rotor Selection Use only the rotors and accessories from this list in the centrifuge The centrifuge is equipped with an Auto Lock locking system This system is used to automatically lock the rotor to the centrifuge spindle The rotor does not have to be bolted on to the centrifuge spindle Proceed as follows 1 Open the lid of th...

Страница 14: ...y until the desired value shows Note If an extremely low RCF value has been selected it will be corrected automatically if the resulting speed is less than 300 rpm Explanation of RCF Value The relative centrifugal force is given as a multiple of the force of gravity g It is a unitless numerical value which is used to compare the separation or sedimentation capacity of various devices since it is i...

Страница 15: ...e desired value by pressing the key repeatedly until the desired value shows 3 The display shows The display shows the current temperature inside the rotor chamber 4 Press the START key The rotor chamber is cooled down or heated up to the preset temperature 5 Press the STOP key The display shows the current temperature inside the rotor chamber Saving Programs 1 Enter the program parameters 2 Press...

Страница 16: ...d you can remove the centrifuged material Temperature Adaptation During Standstill The temperature cannot be adapted until the rotor is positively identified the speed display will then show END When the rotor is not recognized lid closed and START key not yet pressed speed display 0 the centrifuge responds by ensuring that the sample cannot freeze regardless of the rotor being used Short term Cen...

Страница 17: ...uto Lock lid for aerosol tight rotors Aligning the Centrifuge To turn off the centrifuge put the mains switch to 0 CAUTION Rotors supplied with a lid for aerosol tight applications come with a mandrel which belongs to the Auto Lock Be sure not to place the lid onto this mandrel to prevent it from being damaged WARNING Mind the Auto Lock mandrel inside the lid Do not touch the mandrel ...

Страница 18: ...enu End of run beep no Keypad beep no LCD powersave no Auto lid open no Software ID 0547V01 Cycle count 2368 Press the STOP key to exit the system menu English English Deutsch Francaise Español Italiano Nederlands Росский Software and NVRAM identification example values 0547V01 4641V05 yes no ...

Страница 19: ...trifuge should make beep when pressing any key Otherwise use the keys below the bucket selection until it says NO Use the keys below the speed display in order to navigate through the system menu Press the STOP key to quit the system menu LCD Powersave Use the keys below the bucket selection until it says YES in the display if the centrifuge should enter a powersave mode after the run Otherwise us...

Страница 20: ...asp the rotor with both hands and lift it vertically off the centrifuge spindle 5 Remove the centrifuge tubes and adapters 6 Use a neutral cleaning agent with a pH value between 6 and 8 for cleaning 7 Dry all of the rotors and accessories after cleaning with a cloth or in a warm air cabinet at a maximum temperature of 50 C Tread the bold of the swing out rotor with bold grease 75003786 After some ...

Страница 21: ...bes and adapters and dispose of them or decontaminate them 6 Rinse the centrifuge first with ethanol and then with de ionized water 7 Adhere strictly to the given application terms 8 Be sure the decontamination solution can drain off the rotor 9 Rinse the rotor and accessories thoroughly with water 10 Dispose of the decontamination solution according to the applicable guidelines 11 Dry all of the ...

Страница 22: ... technician The service technicians check the following The electrical equipment The suitability of the set up site The lid lock and the safety system The rotor The fixation of the rotor and the drive shaft Unity Lab Services offers inspection and service contracts for this work The cost of any necessary repairs are covered under the warranty Purchase a service contract to cover any services after...

Страница 23: ...k plate with a screwdriver or a knife Pull the release cord attached to it at the same time to trigger the mechanical lid release The lid will open and the samples can be removed Figure 6 Emergency door release Note You need to pull both levers in order to unlock both locks 4 Push the cord back into the centrifuge and mount the plug 5 Reconnect the centrifuge once the power has been restored Switc...

Страница 24: ... be operated The run does not start or the centrifuge runs down without being braked Rotor code is not in the rotor table Check if it is permitted to use the rotor currently mounted in this device Restart the centrifuge If an error message appears again contact Unity Lab Services Rotor ID failure The centrifuge cannot be operated The run does not start or the centrifuge runs down without being bra...

Страница 25: ...rifuge If an error message appears again contact Unity Lab Services E 13 The centrifuge cannot be operated The run does not start or the centrifuge runs down without being braked The check sum in the data memory is incorrect The software corrects errors automatically Check the values of the set point settings etc Restart the centrifuge If an error message appears again contact Unity Lab Services E...

Страница 26: ...3 The centrifuge cannot be operated The run does not start or the centrifuge runs down without being braked Overpressure in the refrigeration unit Clean the air inlet for the condenser Restart the centrifuge If an error message appears again contact Unity Lab Services E 34 E 36 The centrifuge cannot be operated The run does not start or the centrifuge runs down without being braked Error during th...

Страница 27: ...rmation can be found on the back near the inlet for the power supply cable To identify the software version proceed as follows 1 Hold down any of the keys and then switch on the centrifuge You enter the system menu 2 Press the START key 3 Press the or key until the following message is displayed 4 Communicate the software version to the service technician START Software ID XXXXXXXX ...

Страница 28: ...S M S S Aluminum Chloride U U S S S S U S S S S M S S S S S S S S S M U U S S Formic Acid 100 S M U U U S M U U S S U S U S U Ammonium Acetate S S U S S S S S S S S S S U S S S S S S S S S S Ammonium Carbonate M S U S S S S S S S S S S S U U S S S S S S M S S S Ammonium Hydroxide 10 U U S U S S M S S S S S S U M S S S S S S S S S M S Ammoniumhydrox id 28 U U S U S U M S S S S S U S U M S S S S S S...

Страница 29: ... U S U U S S S U S S M U M S S U M S M U S S S Chromic Acid 50 U U U U U S U U S M U M S S U M S U M S Cresol Mixture S S U S S U U U U U U U U U S S S S U S Cyclohexane S S S S S S U S U S S U U U M S M U M M S U M M U S Deoxycholate S S S S S S S S S S S S S S S S S S S S S S S CHEMICAL MATERIAL ALUMINUM ANODIC COATING for ALUMINUM BUNA N CELLULOSE ACETATE BUTYRATE POLYURETHANE ROTOR PAINT COMPO...

Страница 30: ...U S M U U S U U U U U U U U S U S S Ethylene Glycol S S S S S S S S S S S S S U S S S S S S S S M S M S Ethylene Oxide Vapor S U U S U S S M S S S U S U S S S U Ficoll Hypaque M S S S S S S S S S S S S S S S S S S M S S S Hydrofluoric Acid 10 U U U M U U U S S M U S S S S M S U U U CHEMICAL MATERIAL ALUMINUM ANODIC COATING for ALUMINUM BUNA N CELLULOSE ACETATE BUTYRATE POLYURETHANE ROTOR PAINT COM...

Страница 31: ...de U S S S S S S S S S S S S S S S S S S S S U S S S Potassium Hydroxide 5 U U S S S S M S S S S S U S S S S S S S M U M S U Potassium Hydroxide conc U U M U M M S S U M U U U S M M U U U U CHEMICAL MATERIAL ALUMINUM ANODIC COATING for ALUMINUM BUNA N CELLULOSE ACETATE BUTYRATE POLYURETHANE ROTOR PAINT COMPOSITE Carbon Fiber Epoxy DELRIN TM ETHYLENE PROPYLENE GLASS NEOPRENE NORYL NYLON TM PET POLY...

Страница 32: ... S S U U S S S S U U Metrizamide M S S S S S S S S S S S S S S S S S M S S S Lactic Acid 100 S M S U S S S M S S M S M S S S Lactic Acid 20 S S M S M S S S S S S S M S M S S S N Butyl Alcohol S S U S S M U S M S S S S M M S M S S CHEMICAL MATERIAL ALUMINUM ANODIC COATING for ALUMINUM BUNA N CELLULOSE ACETATE BUTYRATE POLYURETHANE ROTOR PAINT COMPOSITE Carbon Fiber Epoxy DELRIN TM ETHYLENE PROPYLEN...

Страница 33: ... S U S S S S Oils Other S S S M S S S S U S S S S U S S S S S S M S Oleic Acid S U S S S U U S U S S M S S S S S S S S S M U S M M Oxalic Acid U U M S S S U S S S S S U S U S S S S S S S S U M S S Perchloric Acid 10 U U S U U S M M M U M S M M M S U S S CHEMICAL MATERIAL ALUMINUM ANODIC COATING for ALUMINUM BUNA N CELLULOSE ACETATE BUTYRATE POLYURETHANE ROTOR PAINT COMPOSITE Carbon Fiber Epoxy DEL...

Страница 34: ...Nitric Acid 50 U S U M S U U S U S U U M M U M M M S S S U S S M S Nitric Acid 95 U U U U U U U U U M U U U U M U U S U S S S Hydrochloric Acid 10 U U M S S S U S S S U U S U S S S S S S S S U M S S Hydrochloric Acid 50 U U U U S U U S M S U U M U U S S S S M S M U U M M CHEMICAL MATERIAL ALUMINUM ANODIC COATING for ALUMINUM BUNA N CELLULOSE ACETATE BUTYRATE POLYURETHANE ROTOR PAINT COMPOSITE Carb...

Страница 35: ...M S S S S S S S S S S S S M S S S S S S S S S S Xylene S S U S S S M U S U U U U U U M U M U U U S U M S U S Zinc Chloride U U S S S S U S S S S S S S S S S S S S S S S U S S S Zinc Sulfate U S S S S S S S S S S S S S S S S S S S S S S S S S CHEMICAL MATERIAL ALUMINUM ANODIC COATING for ALUMINUM BUNA N CELLULOSE ACETATE BUTYRATE POLYURETHANE ROTOR PAINT COMPOSITE Carbon Fiber Epoxy DELRIN TM ETHYL...

Страница 36: ...MPOSITE Carbon Fiber Epoxy DELRIN TM ETHYLENE PROPYLENE GLASS NEOPRENE NORYL NYLON TM PET POLYCLEAR TM CLEARCRIMP TM CCCLEARCRIMP TM POLYALLOMER POLYCARBONATE POLYESTER GLASS THERMOSET POLYTHERMIDE POLYRTHYLENE POLYPROPYLENE POLYSULFONE POLYVINYL CHLORIDE RULON A TM TEFLON TM SILICONE RUBBER STAINLESS STEEL TITANIUM TYGON TM VITON TM S Satisfactory M Moderate attack may be satisfactory for use in ...

Страница 37: ...i Questo prodotto verrà smaltito o riciclato tramite queste medesime Ulteriori informazioni sulla conformità di Fisher Scientific con queste Direttive l elenco delle ditte di riciclaggio nel Vostro paese e informazioni sui prodotti Scientific che possono essere utili alla rilevazione di sostanze soggette alla Direttiva RoHS sono disponibili sul sito www thermofisher com WEEERoHS in Servizi e Suppo...

Страница 38: ...870 241 1034 unity ie thermofisher com Italy 39 02 950 59 478 it fishersci com 39 800 823 162 unity it thermofisher com Finland 358 0 9 8027 6280 fishersci fi 46 8 556 468 20 unity fi thermofisher com France 33 0 3 88 67 14 14 fr fishersci com 33 1 60 92 49 50 unity fr thermofisher com Netherlands 31 0 20 487 70 00 nl fishersci com 31 0 76 579 55 55 unity bnl thermofisher com Norway 47 22 95 59 59...

Страница 39: ...sher Scientific Zweigniederlassung Osterode Am Kalkberg 37520 Osterode am Harz Germany 50156444 is the original instruction manual Find out more at eu fishersci com 50156444 b 15858722 15848722 15838722 15828722 ...

Отзывы: