Thermo Savant FastPrep FP110 Скачать руководство пользователя страница 9

7

This FastPrep

®

Instrument product is warranted against defects in material and workman-

ship for one year after the date of delivery to the original purchaser. This warranty is limit-
ed to defective materials and workmanship, and does not cover incidental or consequen-
tial damages.

Qbiogene will repair free of charge any apparatus covered by this warranty. If a new com-
ponent fails to work, we will replace it, absorb all charges, and continue the one-year war-
ranty period.  Warranty work is subject to our inspection of the unit. No instruments, equip-
ment, or accessories will be accepted without a Return Material Authorization (RMA) num-
ber issued by Qbiogene. Costs of shipping the unit are not covered under warranty. The
warranty obliges you to follow the precautions in this manual.

When returning apparatus that may contain hazardous materials, you must pack and label
them following U.S. Department of Transportation (DOT) regulations applying to trans-
portation of hazardous materials.  Your shipping documents must also meet DOT regula-
tions.  All returned units must be decontaminated.

Use of this equipment in manners other than those specified in this manual may jeopardize
personal safety.  Under no circumstances shall Qbiogene be liable for damages due to the
improper handling, abuse, or unauthorized repair of its products. Qbiogene assumes no lia-
bility, express or implied, for use of this equipment.

Use of non-approved kits and reagents with the FastPrep

®

Instrument is not covered

under this warranty.

5.0

WARRANTY & LIABILITY

Содержание FastPrep FP110

Страница 1: ...Inc North America 2251 Rutherford Road Carlsbad CA 92008 Phone 800 424 6101 Fax 760 918 9313 Qbiogene Inc Europe Parc d Innovation BP72 67042 Illkirch Cedex France Phone 33 0 388 675 425 Fax 33 0 388...

Страница 2: ...tting Target Time 4 3 3 Example of Manual Run 5 3 4 Example of Auto Run 6 3 5 Drying Rate 6 3 6 Other Topics 7 Section Section Title Specifications Page 4 0 Specifications 8 Section Section Title Acce...

Страница 3: ...675 425 Europe or visit the FastPrep Users Resource Group at http www qbiogene com 2 0 INSTALLATION Unpacking Carefully remove the FastPrep Instrument and accessories from the shipping carton Compare...

Страница 4: ...ble power source and the RUN OFF CHANGE switch on the front control panel is turned OFF see Figure 1 Below Once the main power is ON press COVER SPEED TIME COVER switch to release the lid 2 0 INSTALLA...

Страница 5: ...it returns to the OFF position Note While setting run speed the display counts forward in increments of 0 5 m sec within the operating range of 4 0 6 5 m sec B Select desired time of run The units di...

Страница 6: ...ke sure that their screw caps are tight Load sample tubes into the sample holder Whenever possible position the tubes symmetrically The FastPrep Instrument is designed to be used exclusively with the...

Страница 7: ...switch A SPEED TIME COVER to SPEED To display time remaining in the run set switch A SPEED TIME COVER to TIME Note When SPEED is selected on switch A AA is displayed during motor acceleration When th...

Страница 8: ...peed Construction Anodized aluminum sample holder Polypropylene sample retention spoke plate Chemical resistant painted surfaces Dimensions 11 in x 15 75 in x 12 in W x D x H 28 0 cm x 40 0 cm x 30 5...

Страница 9: ...of shipping the unit are not covered under warranty The warranty obliges you to follow the precautions in this manual When returning apparatus that may contain hazardous materials you must pack and l...

Страница 10: ...PENDIX 1 MAINTENANCE CLEANING The cell disruption process during a FastPrep Instrument run is caused by the collision of matrix and sample within the FastPrep Instrument sample tube The rate of collis...

Страница 11: ...interlock override handle is visible underneath situated toward the front The override mechanism is a flat metal handle with release cord wound around attached to the undersurface by two Phillips hea...

Страница 12: ...104 3003 00 Rev B 2000 Thermo Savant...

Отзывы: