36
A. Inputs
Power supplies
Line voltage is applied between the “S1” and “N1” quick connect terminals. 24 VAC Class II
Transformer secondary voltage supplied to X and C
Limit switch
The 120 VAC optically isolated limit switch input is connected on pin P2-1 & 9. Refer to the Heat
Mode section for the control operation.
Thermostat call for heat “W”
24 VAC thermostat input. A call for heat is recognized when the thermostat connects “W” to “R”. This
input has an indicator LED that will light when the control receives a call for heat. Refer to the Heat
Mode section for the control operation.
Thermostat call for cool, “Y”
24 VAC thermostat input. A call for cooling is recognized when the thermostat connects “Y” to “R”. This
input has an indicator LED that will light when the control receives a call for cooling. Refer to the Cool
Mode section for the control operation.
Thermostat call for dehumidification “DEHUM”
24 VAC thermostat input. A call for dehumidification is recognized when the humidistat connects
“DEHUM” to “R”. This input has an indicator that will light when the control receives a call for
dehumidification. Refer to the Cool Mode section for the control operation.
Thermostat call for fan “G”
24 VAC thermostat input. A call for fan is recognized when the thermostat connects “G” to “R”. This
input has an indicator LED in that will light when the control receives a call for fan. Refer to the Fan
Mode section for the control operation.
B. Outputs
PSC Control
The control shall control a five-speed indoor blower motor. Rating shall be 10 FLA, 30 LRA @ 120
VAC. Connections are made via 0.250 x 0.032” male quick connect terminals labeled “HEAT”,
“COOL”, and “LOW”. “HEAT” is energized when the heat speed blower is to run. “COOL” is energized
when the Cool speed blower is to run. “LOW” is energized during a call for fan is received or a call for
dehumidification is received.
Oil Burner
Control
The control provides dedicated contacts to operate the T-T input of an oil primary control.
Rating shall be class 2 – 24 VAC pilot duty @ 24 VAC (<200mA).
Power
The switched 120 VAC power from the LIMIT switch passes through the board between Pins 1 & 2
of connector P1.
Compressor contactor
The control provides switched 24VAC to operate a compressor contactor. Rating shall be class 2 – 24
VAC pilot duty @ 24 VAC (<200mA).
Содержание Thermo Pride OH6FA072D48B
Страница 5: ...2...
Страница 33: ...30 Heating Speed Set ups 2 Stage OH6FX072DV4 Figure 18 2 ECM 2 stage blower motor speed chart...
Страница 64: ...61 VIII Sequence of Operations Flow Chart...
Страница 65: ...62...
Страница 66: ...63 IX Trouble Shooting Flow Chart...
Страница 67: ...64...
Страница 68: ...65...
Страница 69: ...66...
Страница 70: ...67...
Страница 72: ...69 Appendix A Replacement Parts Replacement Parts for OH6FA072D...
Страница 73: ...70 Replacement Parts for OH8FA119D...
Страница 74: ...71 Appendix B Wiring Diagrams OH6FA072D48 PSC Wiring Diagram...
Страница 75: ...72 OH6FA072DV4 ECM Wiring Diagram...
Страница 76: ...73 OH6FX072DV4 ECM 2 Stage Wiring Diagram...
Страница 77: ...74 OH8FA1119D60 PSC Wiring Diagram...
Страница 78: ...75 OH8FA1119DV5 ECM Wiring Diagram...
Страница 79: ...76...