ALL INSTALLATIONS AND SERVICE MUST BE PERFORMED BY QUALIFIED SERVICE PERSONNEL.
This termination vent/combustion air kit is for horizontal or vertical venting of Thermo
Pride's condensing gas furnaces. This kit is designed for extreme cold conditions when
traditional combustion air intakes may frost over causing nuisance shut downs of the
furnace. In addition to cold weather applications, this kit may also be utilized in other
sidewall vent applications where a single hole through the foundation or basement wall
is desired.
The following parts are included in the termination kit.
ITEM DESCRIPTION
AOPS7488 2” KIT
AOPS7489 3” KIT
1
2” Rain Cap
3” Rain Cap
2
3" dia x 19-1/2” long, SDR-26 pipe
4" dia x 24” long, SDR-26 pipe
3
2" dia x 31-5/8” long, SDR-26 Pipe
2-1/2" dia x 37-1/8” long, SDR-26 pipe
4
2” Wye Fitting
3” Wye Fitting
Assembled Concentric Vent Kit
(2” Kit shown)
WYE FITTING
RAIN CAP
OUTER PIPE
INNER PIPE
FIG-1
Follow the furnace installation instructions for locating the furnace, clearances,
operation and safety procedures. Use these instructions for installation of the
concentric vent termination kit. Read these instructions completely before
attempting installation. Field supplied pipe and fittings are required to complete
installation.
Vent Termination Clearances
Determine termination locations based on clearances specified in furnace
installation instructions. The vent termination must be located at least 12” above
ground or normally expected snow accumulation levels.