Operating Instructions (Rev. 12/03)
29
imum of 1/2 hour (longer if possible) before loading the
trailer.
This provides a good test of the refrigeration system
while removing residual heat and the moisture from the
trailer interior to prepare it for a refrigerated load.
6.
DEFROST. When the unit has finished pre-cooling the
trailer interior, manually initiate a defrost cycle. This
will remove the frost that builds up while running the
unit to pre-cool the trailer.
To manually initiate a defrost cycle, press the MODES
key until the dEF (defrost) prompt screen appears, then
press the ENTER key.
Refer to the appropriate Operator’s Manual or Opera-
tion and Diagnosis Manual for detailed information
about Manual Defrost.
The defrost cycle should end automatically.
NOTE: The unit will not defrost unless the evaporator
coil temperature is below 45 F (7 C).
Loading Procedure
1.
Make sure the unit is OFF before opening the doors to
minimize frost accumulation on the evaporator coil and
heat gain in the trailer. (Unit may be running when
loading the trailer from a warehouse with door seals.)
2.
Spot check and record load temperature while loading.
Especially note any off-temperature product.
3.
Load the product so that there is adequate space for air
circulation completely around the load. DO NOT block
the evaporator inlet or outlet.
4.
Products should be pre-cooled before loading. Thermo
King transport refrigeration units are designed to main-
tain loads at the temperature at which they were loaded.
Transport refrigeration units are not designed to pull
hot loads down to temperature.
5.
Post Load Procedure
6.
Make sure all the doors are closed and locked.
7.
Start the unit if it was shut off to load (see Restarting
Unit).
8.
Make sure the setpoint is at the desired setting.
9.
One-half hour after loading, manually initiate a defrost
cycle. If the evaporator coil sensor temperature is
below 45 F (7 C), the unit will defrost. The micropro-
cessor will terminate defrost automatically when the
evaporator coil temperature reaches 58 F (14 C) or the
unit has been in the defrost mode for 30 or 45 minutes
(depending on setting).
Post Trip Checks
1.
Wash the unit.
2.
Check for leaks.
3.
Check for loose or missing hardware.
4.
Check for physical damage to the unit.
Содержание SB-190 30
Страница 4: ......
Страница 8: ......
Страница 14: ...4...
Страница 26: ...Unit Description Rev 12 03 16 Front View AJA890...
Страница 27: ...Unit Description Rev 12 03 17 1 Defrost Damper 2 X430L Compressor 3 se 2 2 Engine Back View 1 2 3 AJA894...
Страница 30: ...Unit Description Rev 12 03 20 ARA158 1 DAS Optional 2 Relay Board 3 Microprocessor Control Box Components 1 2 3...
Страница 40: ...Operating Instructions Rev 12 03 30...
Страница 74: ...64...
Страница 92: ...82...
Страница 100: ...90...
Страница 113: ...103 SB 100 190 Schematic Diagram Page 1 of 2...
Страница 114: ...104 SB 100 190 Schematic Diagram Page 2 of 2...
Страница 115: ...105 SB 100 190 Wiring Diagram Page 1 of 5...
Страница 116: ...106 SB 100 190 Wiring Diagram Page 2 of 5...
Страница 117: ...107 SB 100 190 Wiring Diagram Page 3 of 5...
Страница 118: ...108 SB 100 190 Wiring Diagram Page 4 of 5...
Страница 119: ...109 SB 100 190 Wiring Diagram Page 5 of 5...