Serial Communications 3101/3201
REC
XXXXX
3-6
- COMM. A SCROLL 5 -
Protocol port #1
> MODBUS <
CHOICE ENTER
- COMM. A SCROLL 8 -
Baud rate port #2
> 2400 <
CHOICE ENTER
- COMM. A SCROLL 9 -
Set parity port #2
> No parity <
CHOICE ENTER
- COMM. A SCROLL 10 -
Stop bits port #2
> 1 <
CHOICE ENTER
The next screen defines the port use. Some commonly used protocols are
implemented in the system. Possible selections are:
PC-MASTER
Ramsey proprietary protocol: Multidrop, Master Slave.
SIEMENS 3964R
A proprietary protocol of Siemens. Point to point, Multi Master.
ALLEN-BRADLEY
A proprietary protocol of Allen-Bradley.
DF1 Multidrop,
Master
Slave.
MODBUS
A proprietary protocol of AEG. Multidrop, Master Slave.
PRINTER
Not a protocol, selects printer output.
Password: Service
Default: MODBUS
Selections:
PC-MASTER, SIEMENS 3964R, ALLEN-BRADLEY DF1, MODBUS, PRINTER
If the option COMM A board is installed, the following screen appears. These screens operate
exactly as the ones dedicated to the COMM A on the Mother Board.
Password: Service
Default: 9600
Selections:
110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200
Password: Service
Default: NO
PARITY
Selections:
EVEN PARITY, ODD PARITY, NO PARITY
Password: Service
Default: 1
Selections: 1,2
Содержание Ramsey Micro-Tech 3000 Series
Страница 2: ......
Страница 4: ...Revision History Preliminary December 2003 Manual first released ...
Страница 14: ...Serial Communications 3101 3201 REC XXXXX 2 2 Figure 2 1 COMM A Board ...
Страница 16: ...Serial Communications 3101 3201 REC XXXXX 2 4 Figure 2 3 Serial Connection RS232 ...
Страница 17: ...Serial Communications 3101 3201 REC XXXXX 2 5 Figure 2 4 Serial Connection RS485 ...
Страница 20: ...Serial Communications 3101 3201 REC XXXXX 2 8 Figure 2 5 Mother Board Area of Detail ...
Страница 72: ...Serial Communications 3101 3201 REC XXXXX 3 52 02H 01H 4FH 00H 00H 00H 10H 03H Å AEH 10H Æ 06H Æ ...
Страница 75: ...Serial Communications 3101 3201 REC XXXXX 3 55 ...
Страница 76: ......
Страница 78: ......