Commissioning
After connection of the Thermo-bug®
2.0 basic to the mains 3x400 V, fuse 16 A:
1. Switch on the main switch
(2)
. The fan
is running.
2. Insert the temperature sensor in
socket
(2
.
3. Power switch
(2)
: The heating is
running at half power 4.5 KW.
Power switch
(3)
: The heating is
running at full power 9 KW.
The switches must be pushed in
sequence in the order – to get
full power.
Sockets for temperature sensor
Display for temperature sensor
The display
(2)
can be used to set the
desired temperature and to read the
current temperature. The maximum
temperature can be set via the display
2)
as well (see below).
The temperature sensor should be
placed at a height of approx. 1 m in
open space (not covered), since the
pre-set ambient air temperature will
not be achieved otherwise.
To deactivate the Thermo-bug® 2.0
basic
,
observe the instructions on
page 7.
Thermo-bug 2.0 basic |