background image

EC declaration of conformity

according to the EC machinery 

directive 2006/42/EC from 17 May 

2006, Annex II A

We declare that the following 

machine is designed and built in the 

version marketed by us to comply 

with the basic safety and health

requirements of the EC directive 

2006/42/EC. 
Any changes to the machine not 

coordinated with us will render this 

declaration void.

Description of the machine

Function: High temperature radiator

Type/Model: EL-K-9KW
Correspondence with other

directives/provisions also 

applicable to the product is 

declared: EMC directive (2004/

108/EC) from 15 December 2004

Applied harmonised

standards, specifically: 

n

    DIN EN 12100-1 Safety of  

machinery – Basic terms, general 

principles of design, part 1: General 

terminology, method

n

    DIN EN 12100-2 Safety of  

machinery – Basic terms, general 

principles of design, part 2: Technical 

leading principles and specifications:

n

    DIN EN 60204-1 Safety of  

machinery – Electrical equipment 

of machinery, part 1: General 

requirements

n

    DIN EN ISO13849 Safety of  

machinery - Safetyrelated parts of 

controls

Other applied technical standards 

and specifications:

n

    DIN 40719 Marking of elect.  

operating equipment

n

    VDE 0110/750 Dimensioning of 

creepage and air distances of elect. 

operating equipment

n

    VDE 0298 Current resilience of lines

n

    VDE0 0470 Part 1 Protection types 

through housing

n

    VDE 0701 Inspection of elect. devices

Storage of the documents according to 

annex VI.

Thermo-bug 2.0 basic | 

11

Operating manual 0218

Содержание 2.0 basic

Страница 1: ...Operating Manual Thermo bug 2 0 ...

Страница 2: ...s In particular the danger notes should be given increased attention We assume no liability for damage from improper handling and application the warranty claim lapses The practical thermal exterminator for analogue single operation Thermo bug 2 0 basic Thermo bug 2 0 basic Operating Manual Before delivery the radiator has been reviewed and tested for function Please check the devicefor possible t...

Страница 3: ...Thermo bug 2 0 basic 3 Operating manual 0218 Contents 04 First steps 06 Display and target value settings 08 Product properties and misdiagnosis 10 Safety notes guarantees and general notes ...

Страница 4: ...Thermo bug 2 0 basic First steps Main switch Power switch 4 5 KW Power switch 9 KW 3 3 Sockets for temperature sensor Display for temperature sensor 4 Thermo bug 2 0 basic Operating manual 0218 ...

Страница 5: ...es must be pushed in sequence in the order to get full power The display 2 can be used to set the desired temperature and to read the current temperature The maximum temperature can be set via the display 2 as well see below The temperature sensor should be placed at a height of approx 1 m in open space not covered since the pre set ambient air temperature will not be achieved otherwise To deactiv...

Страница 6: ...T ALM H C Indicator lamps SET Set value setting active OUT Output relay active ALM Alarm relay active H C Cooling function active H C Heating function active Quit button exit menu Function button for target value setting and parameterisation Arrows and parameterisation Operating manual 0218 ...

Страница 7: ...n to confirm the setting Thermo bug 2 0 basic 7 Deactivation Important Switch off power switch and of the Thermo bug 2 0 basic and let the fan lag for at least 5 minutes without heating so that the device can cool off Do not simply pull the plug This would lead to a danger that the connection cables overheat Then switch off via the main switch and disconnect from the mains 3 3 Sek 0 0 0 Operating ...

Страница 8: ... n Pluggable external temperature sensor with 4 m cable n Temperature display with adjustable temperature n 230 V socket for the Thermo bug airblower with a 4A fuse n High performance fan for high temperatures n Overheating protection with automatic resetting n Housing protection type IP54 n Easy handling from low dead weight 15 kg Operating manual 0218 ...

Страница 9: ...vice overheated Main switch off input voltage too high Air supply blocked fan standing Temperature controller is not on or defective PCB fuse defective Imbalance bearing damage No temperature sensor inserted Remedy Attach plug insert again New fuse Let cool off by 15 C switch on Measure mains voltage Keep air supply free cool off Activate replace Replace fuse on the PCB Inform manufacturer Insert ...

Страница 10: ...eplaced by a specialist Guarantee The guarantee period shall be 12 months after the date of purchase of the device Any repairs will be performed free of charge during this warranty period if the defective parts show faults during our inspection Repair will not extend the warranty period The following damage shall be excluded from warranty n Unintended us n Non observation of the instructions n Imp...

Страница 11: ...ally n DIN EN 12100 1 Safety of machinery Basic terms general principles of design part 1 General terminology method n DIN EN 12100 2 Safety of machinery Basic terms general principles of design part 2 Technical leading principles and specifications n DIN EN 60204 1 Safety of machinery Electrical equipment of machinery part 1 General requirements n DIN EN ISO13849 Safety of machinery Safetyrelated...

Страница 12: ...dsee Phone 49 0 7524 401 17 27 Fax 49 0 7524 401 17 28 info thermo bug com www thermo bug com Krempel Co Werbeagentur GmbH Fotos Fotostudio Jacobs Krempel Co Thermo bug ist eine eingetragene Marke der Thermo bug GmbH Thermo bug 2 0 basic Operating Manual ...