RECYCLING AND DISPOSAL

The device is primarily composed of:

Material

Component

steel

structural work

PU (polyurethane)

insulation (models 150 - 550)

polystyrene - polyester felt

insulation (models 800 - 1000)

PE (polyethylene)

water connection washers

ABS (acrylonitrile-butadiene-styrene)

lining and covers

At the end of the device's useful life, these components must be separated and disposed of according to current regulations in 

the country of installation.

END USER INSTRUCTIONS

Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information.

START-UP

The heater commissioning must be performed by Technical 

Assistance Centre personnel.

Under certain circumstances, such as after long periods of 

disuse, the user may need to re-start it without involving the 

Technical Assistance Centre. Before doing so, perform the fol-

lowing checks and operations.

- Check that the supply cocks in the domestic water cir-

cuit are all open

- Switch the electricity supply ON at the mains power 

switch and at control panel switch (if fitted).

TEMPORARY SHUTDOWN

To reduce to the environmental impact and save energy, in 

case of brief absences, week-ends, short trips, etc., and with 

external temperatures above 0°C, set the heater temperature 

control, where available, to the minimum value.

If the temperature to which the heater is exposed can 

fall below 0°C (frost hazard), perform the operations de-

scribed in paragraph "Preparing for extended periods of 

disuse".

PREPARING FOR EXTENDED PERIODS 

OF DISUSE

If the storage cylinder is not going to be used for an extended 

period of time, ask the manufacturer’s Technical Assistance 

Centre to make the system safe.

EXTERNAL MAINTENANCE

Clean the outside of the storage cylinder with a soft cloth 

damped in soapy water.

Do not use abrasive products, petrol or triethylene.

End user

RIELLO S.p.A.

Via Ing. Pilade Riello, 7

37045 - Legnago (VR)

www.thermital.it

The manufacturer strives to continuously improve all products. Appearance, 

dimensions, technical specifications, standard equipment and accessories are 

therefore liable to modification without notice.

Содержание TBSS 150

Страница 1: ...TBSS 150 200 300 430 550 TBSS 800 1000 TBSS INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Страница 2: ...to property or injury to persons or ani mals caused by improper installation adjustment main tenance or use b The product must be serviced at least once a year Servic ing must be arranged in advance...

Страница 3: ...rosion magnesium anode IDENTIFICATION The T TBSS solar heaters can be identified by Data plate This lists the technical specifications and performance of the product BALLON Modele Model Fabrication Co...

Страница 4: ...Continuous availability of domestic water DHW 10 45 C at the different coil inlet temperatures and with the indicated delta T Coil delivery temperature 80 C T 20 C 27 39 49 56 66 69 75 kW 660 950 118...

Страница 5: ...ed to 55 C coil probe point reference and primary exchanger at the indicated delivery temperature considering an increase of the domestic water temperature of 30 C between inlet and outlet according t...

Страница 6: ...ooth open Apply the upper insulation 2 and the upper cover 5 in order to insert the cover exert a light and homoge neous pressure Close the interlocking flaps L completely which were previously left w...

Страница 7: ...431 561 635 622 717 641 706 mm E 523 687 793 780 875 799 864 mm F 663 827 993 980 1075 969 1034 mm G 920 1170 1670 1440 1784 1707 2032 mm H 1088 1338 1838 1644 1988 1835 2155 mm I 604 604 604 755 755...

Страница 8: ...t are all open Switch the electricity supply ON at the mains power switch and at control panel switch if fitted TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brie...

Отзывы: