4

ENGLISH

USER

PRECAUTIONS

GENERAL SAFETY INFORMATION

Do not allow children or 
infirm persons to operate 
the boiler unsupervised. 

Do not operate any electrical 
devices or equipment, includ-
ing switches or domestic appli-
ances, etc., if you can smell fuel or 
fumes. If you detect any suspicious smells: 

  - Ventilate the room by opening all doors and win-

dows. 

  - Close the fuel shut-off cock. 
  - Report the fault immediately to 

THERMITAL

’s 

Technical Assistance Service or a professionally 
qualified heating engineer. 

Never clean or service the boiler without first discon-
necting it from the mains electricity supply by turning 
the main power switch OFF. 

Never pull, disconnect, or twist the electrical cables 
coming from the boiler even if it is disconnected 
from the mains electricity supply at the time. 

Do no obstruct or restrict the vents in the room 
where the boiler is installed. Adequate ventilation is 
essential for correct combustion. 

Do not store containers of flammable substances in 
the room where the boiler is installed. 

Do not touch the boiler when 
barefoot or wet. 

Do not switch the boiler off 
if outside temperature drops 
below ZERO (risk of freez-
ing). 

This instruction manual and that for the installer 
and Technical Assistance Service are integral parts 
of the boiler. They must be kept safe and must 
ALWAYS accompany the boiler, even if it is sold 
to another owner or user or transferred to anoth-
er installation. If you damage or lose this manual, 
order a replacement immediately from your local 

THERMITAL

 Technical Assistance Centre. 

This boiler must be installed by a 
legally qualified heating engi-
neer (in Italy heating engi-
neers are regulated by law 46 
of the 5th March 1990.) On 
completion of the installation, 
the heating engineer must 
issue the owner with a decla-
ration of conformity confirming 
that the installation has been com-
pleted to the highest standards in compliance with the 
instructions provided by 

THERMITAL

 in this instruc-

tion manual, and that it conforms to all applicable laws 
and standards. 

If you notice any water leaking from the boiler, dis-
connect it immediately from the mains electricity 
supply, shut off the water supply, and notify your 
local 

THERMITAL

 Technical Assistance Centre or a 

qualified heating engineer immediately. 

Periodically check that oper-
ating pressure in the water 
circuit is 

over 1 bar

. If water 

pressure is consistently 
low, contact 

THERMITAL

’s 

Technical Assistance Service 
or a professionally qualified 
heating engineer. 

If the boiler is not going to be used for an extended 
period of time, proceed as follows to prepare it for 
shutdown.

 

-  Turn the mains power switch OFF. 

 

-  Close the boiler’s fuel cock and water cock. 

 - 

Drain the central heating circuit if there is any risk

 

  of freezing. 

The boiler must only be used for the purpose spec-
ified by 

THERMITAL

 and for which it is designed. 

The manufacturer declines all responsibility, con-
tractual or other, for damage to property or injury to 
persons or animals caused by improper installation, 
adjustment, maintenance or use. 

The operation of any appliance that uses fuel, electrical power and water demands that a number of fundamental safe-
ty precautions be respected. 

Содержание SUNDAY 200 SOL

Страница 1: ...SUNDAY 200 SOL USER MANUAL...

Страница 2: ...1 Warning LEDs and errors 12 Cleaning 14 Maintenance 14 Useful information 15 CONTENTS This manual Code 20105339 Rev 1 04 17 is made up of 16 pages The following symbols are used in this manual b Iden...

Страница 3: ...be serviced regularly by Technical Assistance Service Their personnel are specially trained to keep your boiler efficient and cheap to run Technical Assistance Centres also stock any original spare pa...

Страница 4: ...ly from your local THERMITAL Technical Assistance Centre bThis boiler must be installed by a legally qualified heating engi neer in Italy heating engi neers are regulated by law 46 of the 5th March 19...

Страница 5: ...the factory The thermostatic mixer valve has to be adjusted to change this value see page 9 4 Green LED When lit shows that a flame is being detected 5 Two figure digital display Displays information...

Страница 6: ...ured by the sen sor over the last few hours is also shown If temperature sensor F2 is not installed the display reads out the message Not connected Storage cylinder top temperature sensor The display...

Страница 7: ...nating manner during automatic venting To interrupt automatic venting remove the central knob and press the combustion analysis button C ON OFF 20 40 60 80 100 4 3 2 1 0 0 120 START UP Have THERMITAL...

Страница 8: ...to the required temperature 20 C Turn the function selector 3 to SETTING CENTRAL HEATING WATER TEMPERATURE USING THE OUTDOOR TEMPERATURE SENSOR Since an outdoor temperature sensor is installed the sy...

Страница 9: ...and cold water inlet pressure 3 bar Knob position Min 1 2 3 4 5 6 7 Max Temperature C 27 32 38 44 49 53 58 63 67 Once you have set the required domestic hot water tem perature you can lock the adjust...

Страница 10: ...mer or room thermostat is installed these must be switched on and adjusted to a temperature higher than current room temperature before the boiler can start up The boiler will remain in stand by mode...

Страница 11: ...n analysis CO in being performed If you are going away for a short period of time like a weekend or a short holiday etc turn the function selector to OFF RESET The digital display reads out the messag...

Страница 12: ...OFF RESET then return it to its previous position Summer or Winter If the boiler does not restart after a number of resets call your local Technical Assistance Centre ON OFF 20 40 60 80 100 4 3 2 1 0...

Страница 13: ...elector to Remove the top front panel from the boiler by pulling it forwards Slowly refill the system opening the fill cock 2 until the pressure gauge reads between 1 and 1 2 bar Fit the top panel bac...

Страница 14: ...boiler without first dis connecting it from the mains electricity supply by turning the main power switch OFF In Italy Presidential Decree n 412 of the 26th August 1993 requires that THE PERSON RESPON...

Страница 15: ...N Seller Mr Address Tel Technical Assistance Service Mr Address Tel Fuel oil supplier Mr Address Tel Installer Mr Address Tel Date Work done Date Quantity supplied Date Quantity supplied Date Quantity...

Страница 16: ...o 7 37045 Legnago VR www thermital it As part of the company s ongoing commitment to perfecting its range of products the appearance dimensions technical data equipment and accessories may be subject...

Отзывы: