22

sequence and providing a brief description of each parameter in the display.

Press “esc” to go back to the previous value, which may need to be checked or changed. Press “esc” repeatedly to return 

to the selection mode and exit the wizard.

 

b

Settings can be activated only by an expert service technician during the start-up procedure! Follow the instruc-

tions given in this manual for the single parameters, and check whether or not further settings are required for the 

particular system.

6.12. Factory settings

All settings introduced can be reset if desired; this will have the effect of restoring the factory-set parameters of the con-

troller.

 

b

A reset will permanently erase all parameterization, analytical and other user-entered data from the controller. Fol-

lowing a reset, the controller must be restarted.

6.13. Time and date

This menu is used to set the current time and date.

 

b

To run analyses on system data, the time must be set correctly at the controller. Remember that the clock will stop if 

the power supply to the controller is cut off for more than about 24 hours, and must then be reset.

6.14. Daylight saving time

When this function is active, the clock updates automatically when Daylight Saving Time (DST) commences and finishes.

6.15. Sleep mode

When sleep mode is selected, the display goes blank after two minutes of inactivity.

 

b

If an error message appears, the display backlighting remains on until the message is acknowledged.

6.16. Temperature unit

This menu is used to select the unit of measure in which temperature is displayed.

7. MENU LOCK

Menu “7. Menu lock” can be used to safeguard the con-

troller against unintentional changes to selected settings.

To quit the menu, press “esc” or select “Exit menu lock”.

7.1 Menu lock

The menus listed below remain fully accessible even 

when the menu lock is active, and can be used to make 

changes if necessary:

1. Measured values

2. Statistics

3. Functioning modes

7. Menu lock

8. Service data

To lock the other menus, select “Menu lock ON”.

To re-enable the menus, select “Menu lock OFF”.

Settings range: On, Off / Default setting: Off.

7.2 Expert mode

This menu lets you switch between expert mode, in which all settings are accessible, and simple mode in which only the 

following menus are available:

1. Measured values

2. Statistics

4.3 Tset

4.4.1 Recirculation 

4.4.5 Recirculation periods

6.10 Time and date

7 Menu lock

9 Language

Settings range: Expert-Simple/ Default: see table.

7.Exit menu lock

7.1.Menu lock 

off

7.2.Expert mode  expert

esc

Info

Содержание MODEX ACS 40 E

Страница 1: ...WORK ON THE PRODUCT The manufacturer reserves the right to modify the product without notice for the purpose of introducing technical im provements or to facilitate production installation and positio...

Страница 2: ...h leakage breaker in accordance with appli cable standards Correct functioning is only guaranteed provided the product is used with the pump for which it is designed The manufacturer cannot be held re...

Страница 3: ...e with temperature sensor primary outlet 5 Pump primary circuit 6 Ball valves DN 20 3 4 F 1 M secondary circuit 7 Red knob for ball valve DHW outlet 8 Blue knob for ball valve cold water inlet 9 Non r...

Страница 4: ...orage cylinder at 55 C and DHW water delivery at 10 45 C 94 0 kW Water draw at 10 45 C with storage cylinder at 55 C 38 5 l min Thermal power absorbed with storage cylinder at 60 C and DHW water deliv...

Страница 5: ...M1 1283 75PWM1 800 85PWM1 p kPa H m P1 W Q m h Q l s Q Igpm Q m h max m ax Wilo Yonos Para RS 15 7 0 20 7 0 25 6 30 7 0 1 230 V Rp1 2 Rp3 4 Rp1 Rp1 1 4 n 1 min PWM 1 45 40 40 45 50 55 60 65 70 75 80 8...

Страница 6: ...MP RS RP EAFS UACS 480 100 80 75 55 45 225 840 ACS 40 E MP Primary inlet 1 M 3 4 F RP Primary outlet return 1 M 3 4 F EAFS Domestic cold water inlet 1 M 3 4 F UACS DHW outlet 1 M 3 4 F RS Recirculati...

Страница 7: ...G DIAGRAM S5 S4 LATO SONDE E CONTROLLO LATO ALIMENTAZIONE 230 V SENSOR AND CONTROL TERMINALS 230 V POWER TERMINALS S4 Storage cylinder top sensor S5 Storage cylinder bottom sensor Connect to controlle...

Страница 8: ...The manufacturer s responsibility ends with the supply of the product The product must be installed in conformity to applicable standards by suitably qualified persons employed by a company that assum...

Страница 9: ...rage cylinder in order to avoid unnecessary heat loss from the connecting pipes b b Handle with care Remove the product from its packaging and remove the polypropylene cover Drill the wall at the posi...

Страница 10: ...iency of the water heating system The ACS 40 E hot water mixer is made from materials that conform to the requirements of Ministerial Decree 174 2004 Italy implementing Council Directive 98 83 EC All...

Страница 11: ...ROCEDURE PRIMARY CIRCUIT b b Fill and bleed the primary circuit with the water at ambient temperature Open the primary circuit inlet and outlet ball valves Set the controller for operation in manual m...

Страница 12: ...d by the technician and by the user of the system before installing setting and operating the controller All accident prevention directives IEC standards local power utility regulations pertinent EN s...

Страница 13: ...nces dispose of the controller with ordinary household refuse Dispose of the controller only at designated collection points or return it to the dealer or manufacturer TECHNICAL SPECIFICATIONS Electri...

Страница 14: ...AN CAN VFS2 VFS1 V2 S6 Control circuit max 12 VAC DC Terminal Connection for S1 Recirculation optional S2 Cold water S3 Primary circuit flow rate optional S4 Top of storage cylinder S5 V1 PWM signal p...

Страница 15: ...s of key functions increase decrease values scroll menu up down yes no confirm cancel Info additional information Back return to previous screen ok confirm selection Confirm confirm setting Finally ac...

Страница 16: ...ure measured is the temperature at the outlet of the heat exchanger which could differ from that measured at the taps Small fluctuations in temperature at the taps are compensated generally by mixing...

Страница 17: ...it settings 4 1 Tset The MFWC controller maintains a constant recirculation temperature by controlling the speed of the hot water pump 4 2 Tmax Maximum draw off temperature at the vor tex flow sensor...

Страница 18: ...es the return to the centre or bottom of the storage cylinder on the basis of temperature This menu sets the temperature differential between the return and the storage cylinder If return temperature...

Страница 19: ...is no lower than 0 C and no higher than the Tmin recirculation setpoint Settings range On Off Default see table 5 4 Seizing protection If seizing protection is active the controller switches on the re...

Страница 20: ...lt setting for Relay 1 is Always on The default setting for Relay 2 is Recirculation Bear in mind that recirculation settings only appear in the settings menu if the recirculation function is activate...

Страница 21: ...l high efficiency pump If a pump function is ac tivated e g recirculation solar additional pump etc the additional settings and speed control for pump V2 must also be set See the technical specificati...

Страница 22: ...nction is active the clock updates automatically when Daylight Saving Time DST commences and finishes 6 15 Sleep mode When sleep mode is selected the display goes blank after two minutes of inactivity...

Страница 23: ...rs etc 9 LANGUAGE Menu 9 Language can be used to select the language in which menus are displayed and navigated Selection is prompted automatically at start up The choice of languages may differ depen...

Страница 24: ...se limescale to form in the heat exchanger REPLACING THE FUSE b b Repairs and maintenance must be entrusted exclu sively to an expert service technician Disconnect the controller from the electricity...

Страница 25: ...g protection Daily Weekly Off Off 6 SPECIAL FUNCTIONS 6 1 1 Pump type 0 10V PWM PWM 6 1 2 Pump Solar Heating Profile 1 11 Manual Heating 6 1 3 Output signal Normal inverted inverted 6 1 4 PWM off Sola...

Страница 26: ...the checks listed in the table below DESCRIPTION OK All automatic or manual filling pumps removed Safety valve calibrated to 6 bar and flow open Drain pipe from safety valve routed suitably Expansion...

Страница 27: ......

Страница 28: ...Legnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modi...

Отзывы: