ENGLISH
31
1. SOLAR COIL INLET
2. SOLAR COIL OUTLET
3. COLD DOMESTIC WATER INLET
4. HOT WATER OUTLET
5. PRESSURE RELIEF VALVE OUTLET (10 bar)
6. REFRIGERANT IN
7. REFRIGERANT OUT
8. ELECTRIC INLETS
9. BOILER THERMOWELL FOR SOLAR SYSTEM
HEIGHT
220 LITRE UNIT 1460 mm
300 LITRE UNIT 1875 mm
WEIGHT
220 LITRE UNIT 95 KG
300 LITRE UNIT 114 KG
Additional information
On the bottom part you will see also other two pipes; they are the refrigerant circuit between
the outdoor unit and the tank.
There is a label near to the pipes; it is reported below:
R410A 3/8” IN is the pipe from the outdoor unit
R410A 3/8” OUT is the pipe to the outdoor unit
Pay the max attention to respect the sense of that connections, both if you are using AF ACS B connected to the
EMX port or the standard port of the outdoor unit
Содержание AF ACS 220 B
Страница 22: ...ITALIANO 22 AFEX AF ACS B AF ACS B AF ACS B 8 8 Flussostato non fornito...
Страница 23: ...ITALIANO 23 AFEX AF ACS B AF ACS B AF ACS B 11 11 Flussostato non fornito...
Страница 24: ...ITALIANO 24 AFEX AF ACS B AF ACS B AF ACS B AF ACS B AF ACS B 8 8 8 8 Flussostato non fornito...
Страница 45: ...ENGLISH 45 AFEX AF ACS B AF ACS B AF ACS B 8 8 Flow switch not supplied OTHER INDOOR UNITS...
Страница 46: ...ENGLISH 46 AFEX AF ACS B AF ACS B AF ACS B 11 11 Flow switch not supplied OTHER INDOOR UNITS...