![thermital 20112939 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/thermital/20112939/20112939_operating-instructions-manual_1104122020.webp)
ENGLISH
1.
Set the
button to DRY. The icon is displayed.
2.
Press the +/- buttons (temperature selection) to set the
desired temperature (the temperature range is between
32 °C max. and 10 °C min.).
AUTOMATIC OPERATION IN MULTISPLIT
CONFIGURATION
When the air conditioning system configuration is multisplit
and there is more than one indoor unit connected, the
automatic mode operates as follows:
- the first unit that switches on the system also decides
the operation mode (cooling or heating) for all the other
units that will be switched on after the first one;
- when the system has been switched on in cooling mode
and one unit is activated in heating mode, an error will
be signaled for this unit (wrong operating mode). If the
same unit is switched on in “automatic” mode and the
desired temperature is lower than the detected ambient
temperature, the unit will operate in cooling mode, like
the other units of the system; on the contrary, if the
desired temperature is higher than the detected one, the
unit will operate in fan mode;
- when the system has been switched on in heating mode
and one unit is activated in cooling mode, an error will
be signaled for this unit (wrong operating mode). If the
same unit is switched on in “automatic” mode and the
desired temperature is higher than the detected ambient
temperature, the unit will operate in heating mode, like
the other units of the system; on the contrary, if the
desired temperature is lower than the detected one, the
unit will operate in fan mode.
DEHUMIDIFYING (DRY)
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
l
Use DRY operation when you want to reduce the humidity
in the room.
l
Once the room temperature reaches the set level, the unit
repeats the cycle of turning on and off automatically .
l
During DRY operation, the fan speed is automatically
set (Remote control lamp
is ON) to prevent
overcooling.
l
Dry operation is not possible if the indoor temperature is
10 °C or less.
NOTE
FAN ONLY
If you want to make air circulate without any temperature
control, press
button until only the fan symbol
appears on the display.
ADJUSTING THE FAN SPEED
AUTOMATIC
Simply set the FAN selector to the position.A
microcomputer automatically controls the fan speed when
the AUTO mode is selected. When the air conditioner
starts operating, in heating or cooling, the fan speed varies
(high - medium - low - very low) according to the thermal
load of the room.
The automatic speed is not available in FAN ONLY mode.
NOTE
MANUAL
If you want to manually adjust speed just set the FAN
selector as desired.
High speed
Med. speed
Low speed
NIGHT MODE / ENERGY SAVING
l
This mode enables you to save energy.
1.
Set the
or
selector to cool, dry or heat.
2.
Press the
button.
3.
The
mark appears on the display. Press the
button again to release the function.
What does the NIGHT mode mean?
When you select the NIGHT mode, the air conditioner will
modify automatically the set temperature after 60 minutes.
This enables you to save energy without sacrificing your
comfort.
OPERATING MODE
SET TEMPERATURE CHANGE
Heating
Lowered by 2 °C
Cooling and Dry
Raised by 1 °C
During the NIGHT mode the internal fan speed is
automatically lowered and reduces the noise.
NOTA
HIGH POWER MODE
When this mode is active the internal fan speed is set
automatically and the air conditioner operates at the
maximum power in the selected operating mode (cooling
or heating).
NOTE
During the high power operation the room temperature
could not correspond to the set temperature.
20