5
ENGLISH
Description of the appliance
The
ACQUAHOME 32 B - 32 BS
boiler produces hot water for
central heating and also produces domestic hot water in an
integrated 110 litre storage cylinder.
It can function at low temperature and is oil fuelled.
The single stage oil burner has a horizontal steel combustion
chamber.
Model
ACQUAHOME 32 BS
(unlike model
ACQUAHOME 32 B
)
has a sealed chamber.
The boiler body is thoroughly and effectively insulated with a
layer of high density glass wool.
The
ACQUAHOME 32 B - 32 BS
boiler's control logic incorpo-
rates a total shutdown function to minimise energy consump-
tion:
- With the mode key set to "Summer", the burner only
starts up to restore the setpoint temperature of the wa-
ter in the storage cylinder;
- With the mode key set to "Winter", the burner starts
up in response to a heat request from the central heat-
ing system (i.e. when the room thermostat switches the
heating on) or to restore the setpoint temperature of the
water in the storage cylinder (DHW heat requests are
prioritised over central heating requests).
Safety devices
ACQUAHOME 32 B - 32 BS
boilers incorporate the following
safety and control devices:
-
A manual reset safety thermostat
that forces a safe-
ty shutdown if boiler temperature exceeds the safety
threshold (100°C). The sensor used to monitor this tem-
perature is located on the body of the heat exchanger;
-
Sensors
that measure the temperature of the boiler and
storage cylinder;
-
An electronic burner controller
that monitors the correct
functioning of the selected burner program and sends
a lockout signal to the control panel in the event of an
error.
b
The intervention of a safety device indicates a potentially
dangerous malfunction in the system. Contact the manu-
facturer’s Technical Assistance Centre immediately.
b
Safety devices must only be replaced by the manufac-
turer's Technical Assistance Centre using original spare
parts. Refer to the spare parts catalogue supplied with
the boiler.
a
Do not use the boiler if any of its safety devices are faulty.
Always check that the boiler is functioning correctly after re-
pairs have been made.
Identification
The products are identified by:
Serial number plate
This is located on the boiler body and specifies the serial
number, model, and main technical specifications.
Mod.
Cod.
N°
Qn(max)
kW
Pn(max)
kW
bar
Pms
T067818GE
Via Mussa, 20 Z.I. - 35017 Piombino Dese (PD) - ITALY
Pms= bar T = °C
Qn(min)=
Pn(min)=
TIPO/TYP/TYP/TYPE/TIPO/TIPO:
COMBUSTIBILE/COMBUSTIBLE/BRENNSTOFF/BRANDSTOF/FUEL/COMBUSTIBLE/COMBUSTÍVEL:
Qn(max)=
Pn(max)=
Mod.
Cod.
N°
kW
kW
kW
IP
W
V~Hz
PAESE DI DESTINAZIONE/PAYS DE DESTINATION/BESTIMMUNGSLAND/LAND VON BESTEMMING:
T067818GE
kW
Via Mussa, 20 Z.I. - 35017 Piombino Dese (PD) - ITALY
S
X
%
mg/kWh
NO
COUNTRY OF DESTINATION/PAÍS DE DESTINO/PAÍS DE DESTINO:
Data plate
This lists the technical specifications and performance of
the product.
DHW section
Central heating section
Qn
Rated heat input
Pn
Rated useful heat output
IP
Electric degree of protection
Pmw
Maximum operating pressure, DHW circuit
Pms
Maximum operating pressure, CH circuit
T
Temperature
η
Efficiency
D
Specific flow rate
NOx
NOx class
b
If these plates or any other means of clearly identifying
the product are defaced, removed or lost, proper instal-
lation and servicing may be rendered difficult.
Содержание 20109806
Страница 1: ...ACQUAHOME 32 B 32 BS INSTALLATION AND MAINTENANCE MANUAL...
Страница 57: ...57 ENGLISH...
Страница 58: ...58 ENGLISH...
Страница 59: ...59 ENGLISH...