H
N
L
TOWEL
WARMER
120 VAC
LINE
GFCI
HOT
NEUTRAL
BLACK
18 AWG
RED
18 AWG
WHITE
18 AWG
BLACK
WHITE
GREEN
16 AWG
GROUND
WIRE NUT
DRAWING NO. PPO4252-1000
GREEN/YELLOW
GREEN/YELLOW
Figure 5
G. Once the Mounting Brackets and Mounting Posts are aligned and adjusted so the posts are all flush with the
brackets, tighten the small inner screw on the bottom Mounting Brackets into the conduit.
H. Now align the Mounting Bracket Covers over the Mounting Brackets and HAND TIGHTEN clockwise.
STEP 4: ELECTRICAL CONNECTIONS
CAUTION: The temperature of the item on the Towel Warmer is conditional on the ambient temperature
and the amount of material hung.
A. All wiring must conform to national and local codes, which may vary by locale. The Towel Warmer requires
120 VAC, 60 Hz power supply. The maximum current draw of the Towel Warmer is 3 amps.
B. Make electrical connections per wiring diagram (Fig 5) and National Electric or Local Codes.