Panel installation
16/48
Note For collectors in rows of batteries it is recommended to keep a distance of at least 1500
mm between one battery and another for flat roof installations and at least 300 mm for
pitched roof installations. However, it is essential that sufficient space is provided to allow
operator access the space between one battery and another.
Key to details and connection examples
Detail
Description
A
Curved or straight compression fitting for copper pipe
Dn22 Compression T fitting with thermowell for copper pipe
Dn22
B
Straight compression fitting for copper pipe Dn22
C
Caps for copper pipe Dn22
D
Curved or straight compression fitting for copper pipe Dn22
Delivery and return from boiler