Installation Guide
WT-C Accumulator tanks
www.thermia.com
Страница 1: ...Installation Guide WT C Accumulator tanks www thermia com...
Страница 2: ...anty if these instructions are not adhered to during installation or service The English language is used for the original instructions Other languages are a translation of the original instructions D...
Страница 3: ...Table of Contents 1 Getting started 4 1 1 Getting started 4 2 Model specifications 5 2 1 WT C 5 2 2 WT C FC Front Connection 8 Installation Guide WT C Accumulator tanks Thermia AB VIBND502 3...
Страница 4: ...side is also fit ted with a velcro on the inside 4 Put the insulation back in the reversed order Adjust the setscrews according to the measures below 1 2 3 1 Foot length is 14mm 2 Maximum length betwe...
Страница 5: ...tres 4x12 6x12 Max pressure hot water heater bar 3 Max pressure coil bar 10 Max immersion heater length mm 670 850 Net weight kg 161 191 Immersion heater max output kW 9 2x9 Standing loss S W 101 127...
Страница 6: ...water coil 2x12m 22mm 6 Preheat coil tap water 2x12m 22mm Technical data Storage volume V 473 litres Test pressure 4 3 bar Working pressure 3 bar Rated temperature 100 C Weight 161 kg Standing loss S...
Страница 7: ...20 x3 5 Immersion heater DN50 6 Preheat coil Tap water 3x12m 22 Technical data Storage volume V 721 litres Test pressure 4 3 bar Working pressure 3 bar Rated temperature 100 C Weight 191 kg Standing l...
Страница 8: ...Working pressure Bar 3 6 3 6 3 6 Test pressure Bar 4 3 8 6 4 3 8 6 4 3 8 6 Max pressure coil Bar 10 Max temperature C 100 Max immersion heater length mm 700 710 840 810 950 910 Weight kg 142 164 187...
Страница 9: ...N20 Technical data Total volume 477 litres Storage volume V 466 litres Total coil volume 11 litres Coil surface per coil 3 m2 Working pressure 3 bar Test pressure 4 3 bar Max pressure coil 10 bar Max...
Страница 10: ...03 litres Storage volume V 492 litres Total coil volume 11 litres Coil surface per coil 3 m2 Working pressure 6 bar Test pressure 8 6 bar Max pressure coil 10 bar Max temperature 100 C Max immersion h...
Страница 11: ...Technical data Total volume 721 litres Storage volume V 704 5 litres Total coil volume 16 5 litres Coil surface per coil 3 m2 Working pressure 3 bar Test pressure 4 3 bar Max pressure coil 10 bar Max...
Страница 12: ...0 Technical data Total volume 676 litres Storage volume V 659 5 litres Total coil volume 16 5 litres Coil surface per coil 3 m2 Working pressure 6 bar Test pressure 8 6 bar Max pressure coil 10 bar Ma...
Страница 13: ...ture sensor DN20 Technical data Total volume 971 litres Storage volume V 949 litres Total coil volume 22 litres Coil surface per coil 3 m2 Working pressure 3 bar Test pressure 4 3 bar Max pressure coi...
Страница 14: ...DN20 Technical data Total volume 907 litres Storage volume V 885 litres Total coil volume 22 litres Coil surface per coil 3 m2 Working pressure 6 bar Test pressure 8 6 bar Max pressure coil 10 bar Max...
Страница 15: ...Installation Guide WT C Accumulator tanks Thermia AB VIBND502 15...
Страница 16: ...ed material Thermia reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes bein...