Clean the strainer as follows:
1. Switch off the heat pump.
2. Turn the stopcock to the closed position (see figure above).
3. Unscrew the cover and remove it.
4. Remove the strainer.
5. Rinse the strainer.
6. Reinstall the strainer.
7. Check that the o-ring on the cover is not damaged.
8. Screw the cover back into place.
9. Turn the stopcock to the open position.
10. Start the heat pump.