4.2
Indicator
The indicator at the bottom of the control panel has three modes:
▪
Not lit, means that the heat pump is not powered.
▪
When the green light shines continuously, the heat pump has power and is ready to produce heat, cool-
ing or hot water, if not in OFF mode.
▪
Flashing green, means an active alarm.
4.3
Display
The display shows information about the heat pump’s operation, status and any alarms.
Sym-
bol
Meaning
Description
COMPRESSOR
Indicates that the compressor is in operation.
LIGHTNING
Indicates that the auxiliary heater is in operation. The number indicates what ad-
ditional step is activated.
HOUSE
Indicates that the heat pump produces heat.
TAP
Indicates that the heat pump produces heat for the water heater.
F
FLOW SENSOR
Indicates that there is flow through the outdoor unit.
CLOCK
Indicates that tariff control is active.
TANK
Indicates the level of hot water in the water heater. When hot water is produced
for the water heater, this is indicated by a flashing icon for the tank.
TANK and
LIGHTNING
A lightning symbol by the tank symbol indicates peak heating charging in domes-
tic hot water tank (anti-legionella function).
DEFROST
Displayed when defrosting is active.
FAN
Displayed when the fan is active.
COOLING
Indicates that the heat pump produces cooling.
POOL
Indicates that the heat pump produces pool heating.
OUTDOOR
TEMP
Shows the outdoor temperature inside the cloud during screen saver mode.
DCM ACCESSO-
RY INSTALLED
Shows that DCM accessory is connected.
ONLINE CON-
NECTION
Shows that DCM accessory is connected, and has internet connection.
The following operating information may also appear: