EN
47
Stable connection to the network by interposing a bipolar switch to ensure
disconnection from the network, with a contact opening distance allowing
complete disconnection under the conditions of the overvoltage category III, in
accordance with the installation rules (Fig. 3.56).
Earth connection (yellow-green wire) should not be interrupted.
If the power cord is damaged, it must be replaced by the manufacturer or its authorized
service center or by a qualified technician, in order to prevent any risk.
Connection procedure:
First of all, connect the motor box to the induction hob:
•
Connect the flat connector (male-female) to the main board, with the controls
falling down from the induction hob (Fig.3.57-A).
•
Connect the main board connector (male-female) with the electronic water sensors
located inside of the hood (Fig.3.57-B).
Fig. 3.56
Fig. 3.57