9
Thermex Antares Room Sealed Conventional Combi Boiler Installation and User’s Manual - ENG
Figure 14
Technicial Specifications
TECHNICAL DATA
15
Condensing Boiler Models
Unit
Thermex
Antares HM 24
Thermex
Antares HM 28
Gas Type
G20
G20
Gas Inlet Pressure (for G20)
mbar
20
20
Type
C12, C32
C12, C32
Category
I2H (G20=20 mbar)
I2H (G20=20 mbar)
Central Heating System
Maximum Efficiency (Partial Load)
%
91,2
91,1
Central Heating Nominal Power (Max) (80-60°C)
kW
23,7
27,5
Central Heating Nominal Power (80-60°C)
kW
9,3
11,4
Central Heating Temperature Adjustment
°C
35-80
35-80
Central Heating Circuit Max. Pressure
bar
3
3
Central Heating Circuit Min. Pressure
bar
0,5
0,5
NOx Class
3
3
Gas Consumption - at Maximum Power
m³/h
2,75
3,20
Gas Consumption - at Minimum Power
m³/h
1,14
1,39
Expansion Vessel Capacity
Liter
8
8
Expansion Vessel Pre-charged Pressure
bar
1
1
Domestic Hot Water (DHW) System
DHW Heating Power, Max
kW
23,1
27,2
DHW Heating Power, Min
kW
9,3
11,4
DHW Volume (∆T = 30°C, Max)
l/min.
11
13
DHW Volume (∆T = 25°C, Max)
l/min.
13,2
15,6
DHW Temperature Adjustment
°C
30-60
30-60
Maximum Operating Pressure
bar
9
9
Minimum Operating Pressure
bar
0,3
0,3
Electrical Specifications
Power Supply Voltage
VAC
230
230
Power Supply Frequency
Hz
50
50
Power Consumption
W
140
140
Electric System Protection Grade
-
IP X4D
IP X4D
Connections to Installation
Gas Connection
inch
3/4
3/4
Central Heating Circuit Flow / Return
inch
3/4
3/4
HDW Inlet / Outlet
inch
1/2
1/2
General Specifications
Flue Diameter - Ø
mm
60/100
60/100
Dimensions (Height x Width x Depth), Without Package
mm
710 x 399 x 335
710 x 399 x 335
Dimensions (Height x Width x Depth), With Package
mm
760 x 430 x 392
760 x 430 x 392
Weight (Without Package)
kg
32
33
Weight (With Package)
kg
34
35