Technicial Specifications

TECHNICAL DATA

15

Condensing Boiler Models

Unit

Thermex

Antares HM 24

Thermex

Antares HM 28

Gas Type

G20

G20

Gas Inlet Pressure (for G20)

mbar

20

20

Type

C12, C32

C12, C32

Category

I2H (G20=20 mbar)

I2H (G20=20 mbar)

Central Heating System

Maximum Efficiency (Partial Load)

%

91,2

91,1

Central Heating Nominal Power (Max) (80-60°C)

kW

23,7

27,5

Central Heating Nominal Power (80-60°C)

kW

9,3

11,4

Central Heating Temperature Adjustment

°C

35-80

35-80

Central Heating Circuit Max. Pressure

bar

3

3

Central Heating Circuit Min. Pressure

bar

0,5

0,5

NOx Class

3

3

Gas Consumption - at Maximum Power

m³/h

2,75

3,20

Gas Consumption - at Minimum Power

m³/h

1,14

1,39

Expansion Vessel Capacity

Liter

8

8

Expansion Vessel Pre-charged Pressure

bar

1

1

Domestic Hot Water (DHW) System 

DHW Heating Power, Max

kW

23,1

27,2

DHW Heating Power, Min

kW

9,3

11,4

DHW Volume (∆T = 30°C, Max)

l/min.

11

13

DHW Volume (∆T = 25°C, Max)

l/min.

13,2

15,6

DHW Temperature Adjustment

°C

30-60

30-60

Maximum Operating Pressure

bar

9

9

Minimum Operating Pressure

bar

0,3

0,3

Electrical Specifications

Power Supply Voltage

VAC

230

230

Power Supply Frequency

Hz

50

50

Power Consumption

W

140

140

Electric System Protection Grade

-

IP X4D

IP X4D

Connections to Installation

Gas Connection

inch

3/4

3/4

Central Heating Circuit Flow / Return

inch

3/4

3/4

HDW Inlet / Outlet

inch

1/2

1/2

General Specifications

Flue Diameter  - Ø

mm

60/100

60/100

Dimensions (Height x Width x Depth), Without Package

mm

710 x 399 x 335

710 x 399 x 335

Dimensions (Height x Width x Depth), With Package

mm

760 x 430 x 392

760 x 430 x 392

Weight (Without Package)

kg

32

33

Weight (With Package)

kg

34

35

Содержание Antares HM 24

Страница 1: ...Thermex Antares HM 24 HM 28 Room Sealed Conventional Combi Boiler www thermex com tr Conventional Combi Boiler Installation And User s Manual Read carefully before operating the appliance ...

Страница 2: ...LIGIBLE FOR WARRANTY 3 4 SWITCHING ON THE BOILER 4 5 DAILY OPERATION OF THE BOILER 4 6 FILLING THE BOILER 4 7 SWITCHING OFF THE BOILER 5 8 MAINTENANCE OF THE BOILER 5 9 INSTALLATION INSTRUCTIONS 5 10 DIMENSIONS OF THE BOILER 6 11 FLUE CONNECTION 6 12 ELECTRIC CONNECTION 7 13 ELECTRIC SCHEME AND ROOM THERMOSTAT 8 14 ERROR CODES 8 15 TECHNICAL DATA 9 INDEX ...

Страница 3: ...r are carried out are in conformity with local requirements as well as to the instructions provided in this manual f Cleaning of external surfaces of the appliance should be made by using a damp cloth do not use any chemical or detergent g The appliance is not designed for children use so its installation is made in such way to make children difficult to access h In order to use the appliance effi...

Страница 4: ...sign may be pressed to make desired selection To set hot water temperature you may use buttons to set the desired temperature In Summer mode pump anti blocking safety and anti frost protection are active b When the appliance is in Winter mode the display shows and signs To set this mode the button with Mode sign may be pressed to make desired selection c To set Central Heating temperature you may ...

Страница 5: ...ns to the boiler and ensure that the installation pipes are free from dirt or any particles Boiler package contains Boiler support Styrofoam installation hanging equipment user s manual warranty certificate and service booklet The locations where the boiler can be installed should beselected by observing the relevant regulations and requirements set forth by standards codes of practice in force as ...

Страница 6: ...ended off the wall it must extend minimum 50 mm outside the wall d Horizontally connected flue connections must be installed with 1 downward slope e Where the appliance is installed to penthouses flue terminal should be minimum 40 cm above the roof In such cases the roof must be insulated with non combustible material f Maximum length of the flue connection is 4 m Maximum length is shortened by 1 met...

Страница 7: ... connection through 3 10 A Automatic circuit breaker 7 Thermex Antares Room Sealed Conventional Combi Boiler Installation and User s Manual ENG ELECTRIC CONNECTION 12 Figure 10 L max 5 m Figure 8 Figure 9 L1 L2 3 m Total equivalent 5 m L1 L2 L3 3 m Total equivalent 5 m 90 elbow equal to 1 m flue length 45 elbow equal to 0 5 m flue length L1 L1 L2 L3 L 2 L1 L1 L2 L3 L 2 Product Total Equivalent Flu...

Страница 8: ...es and warnings to the user through the LCD display Figure 13 In such case if the error does not disappear after performing the indicated action the closest authorised service must be called to fix the error of the appliance ELECTRIC SCHEME AND ROOM THERMOSTAT ERROR CODES 13 14 DESCRIPTION OF THE ERROR ERROR CODE REQUIRED ACTION No fire warning E01 RESET the boiler Flue gas sensor warning E02 RESET...

Страница 9: ...1 39 Expansion Vessel Capacity Liter 8 8 Expansion Vessel Pre charged Pressure bar 1 1 Domestic Hot Water DHW System DHW Heating Power Max kW 23 1 27 2 DHW Heating Power Min kW 9 3 11 4 DHW Volume T 30 C Max l min 11 13 DHW Volume T 25 C Max l min 13 2 15 6 DHW Temperature Adjustment C 30 60 30 60 Maximum Operating Pressure bar 9 9 Minimum Operating Pressure bar 0 3 0 3 Electrical Specifications P...

Страница 10: ...0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 0 000 0 500 1 000 1 500 2 000 2 500 3 000 III II I 6 5 4 3 2 1 0 0 000 0 500 1 000 1 500 2 000 2 500 3 000 III II I 6 7 5 4 3 2 1 0 0 000 0 500 1 000 1 500 2 000 2 500 3 000 III II I 100 0 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 0 000 0 500 1 000 1 500 2 000 2 500 3 000 III II I 100 0 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 0 000 0 500 1 0...

Страница 11: ...ion about the appliance THERMEX in order to develop improve its products preserves the right to modify instruction and user s manual without prior notice 11 Thermex Antares Room Sealed Conventional Combi Boiler Installation and User s Manual ENG ...

Страница 12: ...www thermex com tr Dear Customer Thank you for choosing a Thermex product Revision 2 25 04 2020 ...

Отзывы: