16
OwNER’s mANuAl
Electronic Temp. Controls
All units
Description
The control located on the front of your heat pump has a large three-character
display for the water temperature, set points, and diagnostics (see figure 5
for front panel appearance). The three button keypad includes sET, DOwN
arrow, and uP arrow buttons. lED indicators next to the display show if the
heat pump is in the pool mode or in the spa mode and if the unit is running.
Buttons:
Press the sET button to change between modes and use the up and down
arrows to change the selected mode’s settings.
Modes available are :
POOL Allows you to change the pool water temperature set point.
SPA Allows you to change the spa water temperature set point.
P-S
Changes between pool and spa settings. lED’s on front panel will
indicate current mode selected.
C-F
Display temperature in Fahrenheit or Celsius.
Water Temperature Set Point
Temperature set point range is OFF, and 61°F to 95°F for POl mode. For sPA
mode, set point range is OFF, and 61°F to 104°F. Pushing the uP arrow or
DOwN arrow buttons will prompt the control to display the current set point.
Continuing to press the uP or DOwN buttons will allow the set point values to
scroll until the desired set point is reached. Once the new set point has been
reached, stop pressing the uP or DOwN buttons. Once the unit toggles back
to the current water temperature display, the set point is entered. The controls
have a feature called « set Point memory Retention ». If the power is removed
from the unit, it retains the last set point displayed.
Содержание S100
Страница 1: ...Owner s Manual PRINTED IN CANADA ...
Страница 14: ...14 Owner s manual ...
Страница 26: ......