12
OwNER’s mANuAl
Electrical
The wiring of your THERmEAu pool heat pump should be performed by a
qualified electrician in accordance with local requirements.
The unit must always be deactivated before opening the access panel.
Bonding
Because all metals have different electrical potentials, all metal and electrical
components of the pool system must be bonded together. This includes the
metal framework of the pool, the light, the pump, the filter (if made out of metal),
the heater, any automatic chlorine generator, and any other metal or electrical
equipment. On some older pools, this substructure bond wire may not exist.
In these cases, a 6 to 8 foot solid copper rod must be driven into the ground
near the equipment. All electric and metal components must then be bonded
to each other, and then to the copper rod.
WARNING
!
1. A 1/3 lb check valve must be installed between the heater
and any automatic chlorine distribution system (if used).
2. Any kind of automatic chlorine distribution system must be
installed after or downstream of the heat pump.
3. The filter must be placed before or upstream
from the heat pump.
Bonding and Plumbing
step-by-step instructions
CAUTION
!
WARNING