ThermaZone 003-47 Скачать руководство пользователя страница 5

Avoid these potentially hazardous situations which, if not avoided, may result in minor or moderate 

injury, or damage to the ThermaZone Unit or Brace:

• 

DO NOT position the unit so that it is difficult to operate the disconnection device (plug of the Power supply).

• DO NOT unplug by pulling on the cord.

• DO NOT pull or carry the unit by the cord.

• Unplug from the electrical outlet before cleaning or storing.

• Arrange the blue tubing and cord away from traffic areas and where it will not be tripped over.

• DO NOT drop the unit or brace.

• DO NOT operate or store the unit or brace near pets.

• Before each use, make sure braces are not damaged, punctured or leaking.

• DO NOT puncture the braces.

• To avoid any adverse effects to your health or skin, shut off the unit if you begin to feel discomfort.

• If you are sensitive to hot or cold temperatures, consult your doctor before use.

• Consult the temperature setting warnings and precautions in the instructions when using this unit.

• The application instructions for the ROM Knee Brace are intended for the use of qualified professionals 

 

only. It is not recommended for patients to attempt to apply or adjust this device unless otherwise 

instructed to do so by an orthopedic professional. Any questions regarding further adjustment or  

frequency / duration of wear should direct to your orthopedic professional who understands the individual  

condition for which this device was prescribed.

INTENDED USE

ThermaZone is intended to provide heating or cooling effect at controlled temperatures through  

water-circulating, anatomically designed pads for the application of noninvasive localized thermal therapy. 

The Range of Motion (ROM) Knee Brace provides stability and support for chronic knee pain and

instability. ThermaZone is not meant to replace the program that medical professionals have prescribed 

for their patients. Physician consultation before changing or discontinuing a recommended therapy or 

treatment plan is strongly recommended. ThermaZone pads are not intended to come in contact with 

breached or wounded skin.

CONTRAINDICATIONS 

Absolute Contraindications for 

THERMOTHERAPY

Therapy should 

NOT

 be used in patients without medical supervision:

• If the patients have decreased skin sensitivity;

• If the patients are children, elderly, or incapacitated; and/or

• If the patients have poor circulation, vein ligation, recent skin grafts, or extremely low blood pressure.

Therapy should 

NOT

 be used in patients:

• Who are insensitive to Heat.

Absolute Contraindications for 

CRYOTHERAPY

Therapy should 

NOT

 be used in patients:

• Who have Raynaud’s disease.

• Who are children.

Absolute Contraindications for us of  

RANGE OF MOTION (ROM) BRACE

ROM Brace should 

NOT

 be used in patients:

• Who have moderate to severe ligament instabilities.

SAFETY INSTRUCTIONS

READ THIS FIRST • SAVE THESE INSTRUCTIONS • IMPORTANT SAFEGUARDS

READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THE THERMAL THERAPY DEVICE

CAUTION

Содержание 003-47

Страница 1: ...lexion or Extension Made in U S A This is not a substitute for the ThermaZone Instruction and Safety Manual Review the Instruction and Safety Manual prior to using this pad brace and unit MODEL 003 47 This User s Manual is also available at www therma zone com in English REF www therma zone com Individual Pads Braces work in conjunction with the ThermaZone Thermal Therapy technology and are interc...

Страница 2: ...IN and MAX lines If this is the first time you are using the unit or the first time you have installed a brace the water from the reservoir will be pumped into the chambers of the brace during step 3 At this time you will need to re fill your unit with Distilled Water The temperature can be adjusted during therapy by pushing the or button to increase or decrease temperature You can also check the ...

Страница 3: ...ing from Heat mode to Cool mode remove the brace from your body for 10 minutes MODEL 003 47 REF 7 SET THE RANGE OF MOTION HINGES 8 APPLY YOUR BRACE 9 SECURE THE STRAPS 10 BEGIN THERMAL THERAPY Range of Motion instructions should be provided by your physician Refer to the image to the right to understand the calculation of the angle for Flexion 90 60 30 FULL RANGE 15 0 FULL RANGE FLEXION FLEXION E ...

Страница 4: ...uch items as excessive heat may cause fire electrical shock or other injury DO NOT reach for the unit if it falls into water unplug it immediately DO NOT drop or insert any object or body part into any opening of the unit DO NOT allow unit accessories or cord to touch hot surfaces DO NOT run the cord under carpeting or cover it with throw rugs runners or the like DO NOT attempt to disassemble or r...

Страница 5: ...the individual condition for which this device was prescribed INTENDED USE ThermaZone is intended to provide heating or cooling effect at controlled temperatures through water circulating anatomically designed pads for the application of noninvasive localized thermal therapy The Range of Motion ROM Knee Brace provides stability and support for chronic knee pain and instability ThermaZone is not me...

Страница 6: ...ater or mild detergent Rinse brace with warm tap water and dry with a clean lint free cloth Hinges can be hand washed in cold water with mild detergent Allow parts to air dry before re assembly When used in accordance with the cleaning disinfectant wipe manufacturer s instructions for use the following cleaning disinfection wipes do not adversely affect the appearance or performance of the ThermaZ...

Страница 7: ...ment has a U shaped zipper opening for easy access The compact and easy to carry duffel has a padded shoulder strap and is sized to hold the ThermaZone device and 4 or more orthopedic pads The duffel has additional outside storage zipper accessory pockets to hold accessories The foam insert has a specific cut out to hold the dis tilled water bottle required to operate ThermaZone HOSPITAL BED BRACK...

Страница 8: ...PY PADS SHOULDER PAD STANDARD WARRANTY Limited 3 Month Warranty on ThermaZone Pads and Braces See Instruction and Safety Manual for full warranty details Read Instruction and Safety Manual included with your ThermaZone unit The ThermaZone Instruction and Safety Manual is also available at www therma zone com 2020 Innovative Medical Equipment LLC 103 120 v1 11 2020 BACK HIP PAD ANKLE PAD KNEE ELBOW...

Отзывы: