Shower
wall
Route the M8 cable through the finished wall to the back side
of the control. (The other end of the cable runs to the steam
generator location.) NOTE: It is recommended to run the
cable through electrical conduit. DO NOT STAPLE the cable!
Connect the data cable to Power Distribution Module
(PDM). (The other end of the cable runs to the back of the
control in the shower location.)
THERMASOL.COM
I
800.776.0711
Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
4
DO NOT
pinch, nail, staple, wedge, or
bind the data cable.
DO NOT
wrap the data cable around
steam line or route it in a manner so
that the hot steam line could melt
the cable.
Any damage to the control cable
will result in the control not working
properly.
Carefully connect the data cable to
the PDM and control BEFORE turning
power on to the generator or PDM.
"ON"
Turn Clockwise
"OFF" Turn
Counter Clockwise
• Do not staple, strain or damage data cable
• Align pins to receptacle visually before tightening
• Do not force plug
• Hand tighten only
Connector
Detail
Connect to PDM
PDM requires 110V power
Contact pins
SignaTouch Control Installation Instructions
4
Control Installation and Data Cable Connection
Contact pins Cable ends
M8 Cable
Installation with
generator only
Installation with one of or all, SLSR, Digital
shower valve, and steam generator.