background image

SignaTouch Control Installation Instructions

9

 

Trouble Shooting, Tutorials and Error Codes

Visit www.thermasol.com/solutions. Click on Troubleshoot then click on SignaTouch 

Control Error Codes.

11

11

THERMASOL.COM  

I

  800.776.0711

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

Содержание SignaTouch STCX Series

Страница 1: ...SignaTouch Control OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions STCX XXX ...

Страница 2: ...E A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM DO NOT US...

Страница 3: ...trol Installation Instructions 3 Mud Ring Application Materials needed o SignaTouch control o M8 cable o Silicone o Mud Ring o Other materials as required Silicone Installation instructions warranty static cling warning label 2 Tools and Materials Shower wall Shower wall Mud Ring goes inside wall opening Back of Control Power Data M8 connection Finished wall must be flush with the mud ring Control...

Страница 4: ... cable DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the PDM and control BEFORE turning power on to the generator or PDM ON Turn Clockwise OFF Turn Counter Clockwise Do not staple strain or damage data cable Align...

Страница 5: ...ROL TO THE WALL Power on the control and see that it lights up Coat the entire edge of the control with supplied waterproof silicone to fully seal the control to the wall Completely seal the control to the wall so moisture does not collect behind it Place the control on the wall pressing firmly You may need to tape the control into place until the silicone dries Be careful not to harm the wall or ...

Страница 6: ...1 6a Connecting SignaTouch to the Generator 6b Connecting SignaTouch to Serenity Light Sound Rainhead if applicable Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details M8 Cable M8 Cable M12 Cable 110v ...

Страница 7: ...6 0711 6c Connecting SignaTouch to Digital Shower 6d Connecting Total Wellness Package Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details M8 Cable M8 Cable M12 Cable M12 Cable 110v 110v M8 Cable ...

Страница 8: ...steam line Flow of steam must be unobstructed DO NOT plumb any traps in the steam line The steam outlet on the generator requires a 1 2 brass union for easy installation not included Use 1 2 brass pipe or copper tubing from unit to steamhead rough in fitting as permitted by code A B The steam line can run up and then down once or horizontal but never run down and then up If it does a steam trap wi...

Страница 9: ...t rough in fitting and install to be flush with the finished wall this housing must be sealed to the wall to not allow vapor or water behind it plumbing must be done from backside of finshed space For new framing Mount and install rough in fitting to be flush with finished wall Connect a 1 2 NPT brass pipe or copper tubing to the steam outlet union not included on the generator running the pipe to...

Страница 10: ...r illustrative purposes only Consult with qualified professional for steam room construction details THERMASOL COM I 800 776 0711 Upon final installation mount steamhead with facing up to allow aromatherapy well to dispense steam For detailed installation instructions of the steamhead please see Installation section in thermasol com customer support SignaTouch Control Installation Instructions App...

Страница 11: ...nd Error Codes Visit www thermasol com solutions Click on Troubleshoot then click on SignaTouch Control Error Codes 11 11 THERMASOL COM I 800 776 0711 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details ...

Страница 12: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81220_NC ThermaSol uses the following open source project Qt5 GUI Framework www qt io LGPLv3 ...

Отзывы: