- 36 -
- 37 -
Procedure
Illustration
- 36 -
Removing Manifold Assy
(1)Disconnect Flame Rod connector.
(2)Remove Ignitor.
(see previous step)
(3)Remove the setscrew fixing the PCB
case. Lift the case up and pull it out.
(4)Remove the setscrews fixing the
Manifold Assy (M4 x 7 pcs, M4 with
washer x 3 pcs).
(5)Pull the connector of the Gas Valve 3
(Model 26 only)
Removing Gas Control Valve
(1)Remove Manifold Assy. (see previous
step)
(2)Remove setscrews(4 pcs).
Gas Control Valve setscrews(4 pcs)
Setscrews
M4 with washer x 3 pcs
Setscrews
M4 x 7 pcs
Connector of the Gas Valve 3
Flame Rod connector