OPERATION - MODE 1
Mode "1" - Operation
When the preheater is set to Mode "1", the system uses the external temperature
sensor "b" ("6b" in control diagram) to control the preheater temperature. The external
temperature sensor "c" is used for additional monitoring.
Note: In order to measure
temperature correctly, kapton tape must be used to securely fix sensor B to the
PCBA or component. If sensor B cannot accurately report temperature then the
preheater temperature may run out of control.
1. Follow "Operation - Mode Selection" Instructions
2. The digital display will show:
(1.a) upper digital display will show "
set
"
(2.a) lower digital display will show "
XXXA
" (xxx denotes temperature)
Press the "▲" button or "▼" button to adjust temperature
Note: The set temperature is adjustable from 50C to 280C in this mode.
3. Press the selection button to confirm the set temperature, the preheater will begin to
heat up to the set temperature.
Mode "1" - Display
Viewing the actual temperature of external sensor "b"
Press the selection button ("2" in control diagram) repeatedly until the upper digital
display shows "
ACT1
". The lower digital display will show the actual temperature of "b".
Viewing the actual temperature of external sensor "c"
Press the selection button ("2" in control diagram) repeatedly until the upper digital
display shows "
ACT2
". The lower digital display will show the actual temperature of "c".
Simultaneously viewing the actual temperature of external sensor "b" and "c"
Press the selection button ("2" in control diagram) repeatedly until the upper digital
display shows "
XXXB
" and the lower display shows "
XXXC
".
Note: Under Mode "1", it is not necessary to monitor the internal temperature
sensor's read out.