TMT-PH300 IR Preheater

USER MANUAL

OPERATION - MODE 2

Operation - Mode "2"

When the preheater is set to Mode "2", the system uses a custom temperature/time 
profile to control temperature. The external temperature sensor "b" ("6b" in control 
diagram) is used to control the preheater temperature. The external temperature 
sensor "c" is used for additional monitoring. 

Note: In order to measure temperature 

correctly, kapton tape must be used to securely fix sensor B to the PCBA or 
component. If sensor B cannot accurately report temperature then the preheater 
temperature may run out of control.

1. Follow "Operation - Mode Selection" Instructions
2. Press the selection button ("2" in control diagram), the display will show "

run prof

"

3. Press the selection button. The digital display will show: 
   

(1.a) upper digital display will show "

seg1

"

   

(2.a) lower digital display will show "

XXXt

" (xxx denotes time in seconds)

  Press the "▲" button or "▼" button to adjust the time (5 to 200 seconds)

Note: For safety, the temperature rise is limited to no more than 3C per second.

4. Press the selection button. The digital display will show: 
   

(1.a) upper digital display will show "

seg1

"

   

(2.a) lower digital display will show "

XXXC

" (xxx denotes temperature)

  Press the "▲" button or "▼" button to adjust the temperature (50C to 250C)

5. Repeat step 3 and 4 setting the time and temperature for segments 2 through 6 

(SEG2/3/4/5/6).

6. To start the preheating profile, repeatedly press the selection button until "

Run 

Prof

" is displayed, than press the "▲" button to start. A three second countdown 

will commence before the profile is initiated.

7. To see the current segment, the running time, or the temperature of the sensors, 

repeatedly press the selection button to switch between the different display modes.

8. After the profile finishes running, the display will show "

End

"

9. Press the press the "▲" button to save the profile and exit to profile adjustment 

mode.

Note: To exit the running profile before the process finishes, press the "▲" 
button. The system will exit and return to the profile adjustment display.

Содержание TMT-PH300 Series

Страница 1: ...USER MANUAL TMT PH300 IR PREHEATER www thermaltronics com ...

Страница 2: ......

Страница 3: ...altronics will repair or replace it free of charge at its sole option Warranty period is from the date of purchase by the original owner If the date of purchase cannot be substantiated the date of manufacture will be used as the start of the warranty period TABLE OF CONTENTS TMT PH300 SPECIFICATIONS 1 INTRODUCTION 1 SYSTEM FEATURES 1 SAFETY PRECAUTIONS 2 CONTROL PANEL 3 UNPACKING ASSEMBLY OPERATIO...

Страница 4: ...ature control technology for accurate temperature control Three heating modes allow the unit to handle leaded lead free preheating processes and are suitable for use with PCB containing BGA and SMD components Functions and Features 1 CPU controlled IR Heater provides accurate temperature control 2 Three heating modes to meet different soldering requirements 3 Professional board holder allows three...

Страница 5: ...r prolonged periods of time 3 Never operate the equipment with wet hands 4 Always disconnect the power cord and allow the unit ample time to cooldown before performing maintenance 5 Use only genuine replacement parts Caution 1 Use this equipment in a well ventilated area away from combustible equipment 2 Disconnect the power cord if unit is not used for extended period of time 3 Handle with care N...

Страница 6: ...on button 7 Power Switch 3 Increase Enter button 8 Power Socket 4 Decrease button 9 Fuse Holder Digital Display Suffix A b c d C t Set temperature for Operation Mode 0 and 1 Actual temperature of external sensor b Actual temperature of external sensor c Actual temperature of internal sensor d Set temperature for profile Set duration time seconds for profile ...

Страница 7: ...H KTC 1 sensors to the sensor ports 6 in control panel diagram Verify that the sensors are properly inserted 3 Connect the AC plug to a suitable AC power outlet Make sure the power outlet has grounding 8 in control panel diagram 4 Turn the unit on 7 in control panel diagram Note SENS ERRX will display if external sensor port X is not connected properly Operation Mode selection 1 The digital displa...

Страница 8: ...ter will begin to heat up to the set temperature Mode 0 Display Viewing the actual temperature of external sensor b Press the selection button 2 in control diagram repeatedly until the upper digital display shows ACT1 The lower digital display will show the actual temperature of b Viewing the actual temperature of external sensor c Press the selection button 2 in control diagram repeatedly until t...

Страница 9: ...just temperature Note The set temperature is adjustable from 50C to 280C in this mode 3 Press the selection button to confirm the set temperature the preheater will begin to heat up to the set temperature Mode 1 Display Viewing the actual temperature of external sensor b Press the selection button 2 in control diagram repeatedly until the upper digital display shows ACT1 The lower digital display ...

Страница 10: ...on to adjust the time 5 to 200 seconds Note For safety the temperature rise is limited to no more than 3C per second 4 Press the selection button The digital display will show 1 a upper digital display will show seg1 2 a lower digital display will show XXXC xxx denotes temperature Press the button or button to adjust the temperature 50C to 250C 5 Repeat step 3 and 4 setting the time and temperatur...

Страница 11: ...50s 60s to get to 150 celsius Calculating the Temperature Ramp Rate The temperature ramp rate is calculated as the following Ramp rate Temp Change Time If two heating zones have the same temperature then the temperature stays constant 1 SEG1 Heating zone Temperature ramps up to 100 celsius in 50 seconds Ramp rate 100 50 Ramp rate 2 celsius second 2 SEG2 Heating zone Temperature ramps up to 150 cel...

Страница 12: ... sensor C and make sure it is connected properly If issue persists replace with new one PH KTC 1 Q Error Messages ERR1 A Check external sensor B and make sure it is connected properly If issue persists replace with new one PH KTC 1 Q Error Messages ERR2 A Check internal sensor D and make sure it is connected properly Please consult your local vendor Q Error Messages ERR3 A Indicates a bad sensor c...

Отзывы: