background image

                                                                                                      

 

1751 Hurd Drive ● Irving, Texas 75038 ● (972) 580-0200 ● (888) 580-0202 ● Fax (972) 580-0277 

URL:  www.thermal-edge.com ● Email:  

[email protected]

 

SP-ENG-210-000-10 Rev 1.3          

24 

|

 

P a g e

                                                                                   

Warranty Information 
 

Thermal Edge products are warranted to be free of defects in workmanship , materials and components. 
The warranty period applies from date of shipment for one year.  

The above warranty applies when the equipment is operated under the following conditions:  

 

Ambient temperature not in excess of performance rating in normal atmosphere or as stated on 
product nameplate 

 

Voltage variation no greater than ± 10% from nameplate rat ing 

 

Frequency variation no greater than ± 3Hz from nameplate rating 

 

Maximum cooling load no higher than air conditioner nameplate rating  

 

Waiting five minutes before restarting air conditioner after intentional or accidental shutoff  

 

Compliance to all other installation, maintenance and operating instructions, as supplied 

Thermal Edge cannot assume responsibility for misapplication of its products or the erroneous selection of 
an inappropriate product by a non-authorized Thermal Edge representative. Our applications engineers 
will gladly assist in the selection of the proper product provided all required details of the application are 
furnished. 

Thermal Edge assumes no liability beyond the repair or replacement of its own product. This Warranty 
does not cover: 

 

Labor or reimbursement of labor for evaluation, removal, installation, repair, or cost of any 
warranted part, except at the Thermal Edge factory in Dallas, Texas 

 

Use of equipment for other than its designed purpose or operating conditions  

 

Operation in harsh, oily, corrosive or other abnormal environmental conditions, without the proper 
filtration, sealing, protective coatings and/or weather protection  

 

Damage to hermetic system resulting from continuous operation with dirty or clogged air filters or 
improper or negligent maintenance 

 

Use of refrigerant other than designated 

 

Customer modification or abuse 

 

Shipping damage or other accident 

 

Repair or service by unauthorized personnel. 

Cracked or broken hermetic tubing or brazed joints caused by shipping damage o r mishandling are not 
covered under the Warranty.  Claims for shipping damage are the responsibility of the Consignee. Timely 
claims must be filed with the freight carrier. 

The purchaser assumes the responsibility of grounding the unit and installing it in  accordance with local 
electrical and safety codes, as well as the 2008 National Electric Code (NEC) and OSHA. 

THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE PRODUCT AND 
IS IN LIEU OF ALL OTHERS, EXPRESSED OR IMPLIED, INCLUDING ANY WARRA NTY OF 
MERCHANTABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO 
EVENT IS THERMAL EDGE RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE 
WHATSOEVER. 

Содержание WF060 Series

Страница 1: ...User Technical Manual WF060 WF080 Series Rev 1 3...

Страница 2: ...Slotnick Update filter media part number Statement of Confidentiality The Manual and other materials contain proprietary information comprising Thermal Edge Inc s trade secrets Please maintain the co...

Страница 3: ...the Air Conditioner 4 Moving the Air Conditioner 5 Unit Label 5 Operation 6 Preliminary Testing 6 Mounting the Air Conditioner 7 Unit Specifications 8 Options 10 System Faults 13 Digital Temperature C...

Страница 4: ...nspecting the Equipment Thermal Edge air conditioning equipment is designed manufactured and packed to prevent damage from normal handling shock and vibration during shipment It is necessary to inspec...

Страница 5: ...degree angle rotary compressors without damaging the compressor If air conditioner is to be shipped or transported at any time pack in original packaging and strap to pallet to prevent damage Air con...

Страница 6: ...ped with a Condensate Removal System that changes the excess humidity liquid into a vapor which is then vented to the atmosphere In the event of excess water vapor where the enclosure door has been le...

Страница 7: ...nt the air conditioner high on the enclosure in order to cool the hot air in the top of the enclosure Position the unit where the cold air can circulate across the width of the enclosure to cool it al...

Страница 8: ...um Ambient 125 F Unit Weight 100lbs 120 230VAC Model Operating Voltage Range Volts Inrush Current Start Up Current Amps Loading Current Running Current Amps SCCR Short Circuit Current Rating Amps Reco...

Страница 9: ...KVA Rating K Watts Refrigerant Type Refrigerant Amount ounces Low High Unit Pressures psi WF080126 110 120 42 70 13 00 2 25 Amp Class CC CCMR Time Delay 1 5 R422d 26 00 144 335 WF080236 220 240 24 20...

Страница 10: ...ide an optimum constant low current in the compressor motor during the non cooling state This option provides internal heat to the compressor to protect it from stalls and hard starts during long peri...

Страница 11: ...ies available are 100 Watt 150 Watt 200 Watt 250 Watt 300 Watt 400 Watt 550 Watt 650 Watt 950 Watt Default Settings 55 F Heat Set Point 3 F Differential At the default settings the heater output turns...

Страница 12: ...mperature at any specific location of your enclosure Ethernet IP Controller Output This option provides the ability to communicate with the Thermal Edge Air Conditioner controller via the Ethernet IP...

Страница 13: ...nute time delay A thermal overload protects the compressor against faults In the event that the snowflake status LED is not flashing on the display and the compressor is not running an internal fault...

Страница 14: ...T key to display its value 4 Use the UP or DOWN arrow key to change its value 5 Press SET to store the new value and move to the following parameter To exit Press SET UP arrow keys or wait 15 seconds...

Страница 15: ...l 30 min start up delay No Output 2 HA2 Condenser High Temperature Alarm P2 145 F for 3 minutes Compressor Off 2 LA2 Condenser Low Temperature Alarm P2 50 F for 3 minutes No Output 2 CA Evaporator Coi...

Страница 16: ...e is recommended to enhance air filter efficiency Replacement filters are readily available from THERMAL EDGE Customer Service DO NOT operate the air conditioner without the air filter Such operation...

Страница 17: ...r 120VAC 31574 1 for 230VAC Compressor Thermal Overload WF060 31552 2 for 120VAC WF080 31553 2 for 120VAC 31574 2 for 230VAC Gasket Installation Kit 71308 WF68 Evaporator Fan 42100 1 1 for 120VAC 4210...

Страница 18: ...itch is on position ON OFF Toggle Switch then Retry Verify input power meets voltage requirements as shown in the UL label YES If problem is still present contact technical support Unit Overheats Insu...

Страница 19: ...pressor Use meter 3 Check for faulty evaporator fan 3 Measure Temperature at Evaporator Verify Heat Load Requirements Is unit capacity adequate for internal head load Possible low refrigerant Is compr...

Страница 20: ...behind controller CA YES NO Check Low Pressure Switch Connections and Verify Pressure switch is closed Use meter 3 P1 or P2 NO YES Check probe connections potential faulty probe LA LA2 HA HA2 YES Ref...

Страница 21: ...hysical Dimensions 120 230 VAC Models Water overflow excessive Check drain is it plugged YES NO Clean condensate pan and drain add 1 tbsp bleach to upper pan monthly to kill mold Is Air Conditioner se...

Страница 22: ...d Drive Irving Texas 75038 972 580 0200 888 580 0202 Fax 972 580 0277 URL www thermal edge com Email thermaledgeinfo thermal edge com SP ENG 210 000 10 Rev 1 3 22 P a g e THIS PAGE IS INTENTIONALLY LE...

Страница 23: ...ermal edge com SP ENG 210 000 10 Rev 1 3 23 P a g e Electrical Schematics System Schematic Digital Controller Schematic Note Schematics applies to all voltages optional accessories wiring not provided...

Страница 24: ...the repair or replacement of its own product This Warranty does not cover Labor or reimbursement of labor for evaluation removal installation repair or cost of any warranted part except at the Therma...

Страница 25: ...nd address Shipping method Pack unit in a suitable packing for shipment preferably the original packaging if available If suitable packing is not available arrange for packaging to be shipped to you A...

Отзывы: