Thermal Technology WABO NTA 100L Скачать руководство пользователя страница 11

Thermal Technology powered by Carbon Fiber Heating SRL - Str Calea Borsului Nr 53B - 410605 Oradea (BH) Romania

Phone: + 39 0423 858589 - www.thermaltt.com - [email protected]

11

Press         for confirmation or         for exit without confirmation the change.

CLOCK TIMER SETTING:

The controller allows setting of maximum 2 operating intervals, for each of them it is 
possible to choose the desired temperature. Press         key, the display will show 

PAR

press         or        key until the display will show the wording 

CRONO

 press the key         

to enter. By pressing         and         the display will indicate:

ON 1

 setting switch on time for interval 1

TMP 1

 setting the desired temperature for interval 1

OFF 1

 setting switch time for interval 1

ON 2

 setting switch on time for interval 2

TMP 2

 setting the desired temperature for interval 2

OFF 2

 setting switch off time for interval 2

Press         key to access the parameter and set it.
To remove an operation interval, modify the hour until the display will indicate 

--:-- 

flashing.

EXAMPLE:

Setting interval 1, starting at 

06:00

 and finishing at 

08:15

 with a set point temperature of 

65°C

Press         key, the display will indicate the wording 

PAR

, press         or          until the 

display will indicate the wording 

CRONO

 press the key           to enter. 

The display will indicate 

ON 1

,

 

press         key .

The display will indicate the wording 

 --:--  

flashing or the activation time set before.

Press the         or         to set the activation time until you see 

06:00

, then press        key, 

the display will indicate 

TMP 1

, press the button          the display will indicate 

S.60°C

 

flashing. Using the keys        or          set the temperature 

S. 65°C

 and press            key.  

The display will indicate the wording 

OFF 1

 press         key. The display shows 

--:-- 

flashing or activation hour set before.

Содержание WABO NTA 100L

Страница 1: ...ELECTRIC WATER HEATER WABO User and maintenance instructions...

Страница 2: ...of carbon fiber resistors and partialization of the power load The device is managed by an electrical controller equipped with two probes located in the upper and lower part of the tank for permanent...

Страница 3: ...es 4 02 Warnings 4 03 Product identification 5 04 Package content 6 05 Installation cautions 6 06 Installation and connection 6 07 Warnings 6 08 First activation 8 09 User instructions 9 10 Maintenanc...

Страница 4: ...heck valve a safety valve a breaking device for the hydraulic load This equipment must be used for the purpose for which it was intended Any contractual liability or extra contractual liability of the...

Страница 5: ...1610 1780 Supply V 230 230 230 Heating time t 45 C h min 2 32 Maximal operation temperature C 90 90 90 Thermal dispersion at 65 C kWh 24h 1 37 Max operation pressure bar 6 6 6 Net weight Kg lb 16 35...

Страница 6: ...w Two L screws for wall support must be placed on the wall capable of supporting a weight of at least 120 kg The position of the fixing screws is calculated considering the final position of the boile...

Страница 7: ...tures below zero Do not leave it exposed to the rain wind or any weather agents Do not install the product on power lines without protection from surges or variations For the safety of the device is n...

Страница 8: ...shower If installed near a bathtub a shower or a sink must be respected the standard distances that are normally at least 60 cm from the various edges THE INSTALLATION IN AREA 0 AREA 1 OR AREA 2 IS FO...

Страница 9: ...is equipped with 4 keys ON turns ON OFF the boiler manually PAR access to different parameters menu navigation and changing the values Signalisation led Lighting permanently reports heating at full re...

Страница 10: ...tins the display will indicate S 65 C flashing press or keys to set the desired temperature and the accumulated water and the key for confirmation and key for exit without confirmation the change TIME...

Страница 11: ...2 setting the desired temperature for interval 2 OFF 2 setting switch off time for interval 2 Press key to access the parameter and set it To remove an operation interval modify the hour until the di...

Страница 12: ...t until the heating elements will be cooled It is reccomended the cleaning of the tank at least each two years depending on the water hardness Magnesium anode must be replaced each 2 years 11 Protecti...

Страница 13: ...web site in order to find out hardness level of the water in each area In order to measure it you can use appropriate reusable kits affordable in plumbing stores Failure to apply these measures or non...

Страница 14: ...ar in mind the interdiction of casting the product as municipal waste you will find under the product s identification plate the following mark crossed bin Differential casting of electric and electro...

Страница 15: ...d of 5 FIVE YEARS for the product starting with acquisition date The warranty conditions are exclusively those presented in FREE CONVENTIONAL COMMERCIAL WARRANTY downloadable from our website section...

Страница 16: ...10605 Oradea BH Romania Phone 39 0423 858589 www thermaltt com info thermaltt com 16 For technical assistance contact Thermal Technology powered by Carbon Fiber Heating SRL Str Calea Borsului Nr 53B 4...

Отзывы: