![Thermal Dynamics Pak Master 75XL Plus Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/thermal-dynamics/pak-master-75xl-plus/pak-master-75xl-plus_service-manual_1103266027.webp)
Manual 0-2747
4-9
TROUBLESHOOTING
2. Faulty PCR Relay
a. With power off, measure for continuity between
wires #12 and #14. If continuity is found, re-
place PCR.
3. Faulty Logic/Gate PC Board
If torch tip is off the workpiece and the drag indi-
cator, D36, on the Logic/Gate PC Board is still ON,
then replace the Logic/Gate PC Board.
4.09 Test Procedures
The test procedures in this subsection are referenced in
the troubleshooting section.
A. Safety Precautions
1. Significant DC Voltage exists after removal of input
power. Allow 2 minutes for discharge time. Voltage
measured on input capacitors must be zero before
performing service on the power supply.
2. Do Not touch electrical components with any part of
the human body when power is applied.
3. Keep away from any moving parts.
4. Hot surfaces can cause severe burns. Allow equip-
ment to cool before servicing.
5. Electrostatic discharge can damage printed circuit
board assemblies. Transport printed circuit boards in
proper anti-static shielded packages. Use proper
grounding techniques with wrist strap before handling
printed circuit boards.
6. Misaligned plugs can cause printed circuit board dam-
age. Be sure plugs are properly aligned and com-
pletely seated.
7. Excessive pressure can damage printed circuit board.
Use only minimal pressure and gentle movement
when disconnecting or connecting printed circuit
board plugs.
B. Opening Power Supply Enclosure
The left side panel of the Power Supply must be removed
for access to the input power connections and the input
voltage selection.
WARNING
Disconnect primary power at the source before as-
sembling or disassembling the Power Supply, torch
parts, or torch and leads assemblies.
1. Remove the screws which secure the left side panel
(viewed from front of unit) to the frame assembly.
A-02564
Left Side
Panel
Screws (5 places)
Ground Wire
2. Carefully pull the left side panel from the Power Sup-
ply a short distance (see note).
NOTE
There is a ground wire attached to the side panel.
3. Remove the nut securing the ground wire to the side
panel.
4. Close the enclosure by reversing the above steps.
C. Diode Testing Basics
Testing of diode modules requires a digital volt/ohmme-
ter that has a diode test scale. Remember that even if the
diode module checks good, it may still be bad. If in doubt,
replace the diode module.
1. Locate the diode module to be tested.
2. Remove cables from mounting studs on diodes to iso-
late the module.
3. Set digital volt/ohmmeter to diode test scale.
4. Using the Figures for each test, check each diode in
the module. Each diode must be checked in forward
bias (plus to negative) and reverse bias (negative to
plus) direction.
5. Connect the volt/ohmmeter positive lead to the an-
ode (+) of the diode and the negative lead to the cath-
ode (-) of the diode for forward bias testing (refer to
following figure). A properly functioning diode will
conduct in the forward bias direction and indicate be-
tween 0.3 to 0.9 volts.
Содержание Pak Master 75XL Plus
Страница 2: ......
Страница 6: ......
Страница 16: ...INTRODUCTION 2 2 Manual 0 2747...
Страница 49: ...Manual 0 2747 6 5 REPLACEMENT PARTS This page left blank...
Страница 71: ...Manual 0 2747 A 15 APPENDIX Notes...
Страница 72: ...APPENDIX A 16 Manual 0 2747 APPENDIX 12 SYSTEM SCHEMATIC A 02503...
Страница 73: ...Manual 0 2747 A 17 APPENDIX A 02503...
Страница 74: ......