background image

Manual 0-4688

1-3

GENERAL INFORMATION

6. ANSI Standard Z49.2, FIRE PREVENTION IN THE USE

OF CUTTING AND WELDING PROCESSES, obtain-
able from American National Standards Institute, 1430
Broadway, New York, NY  10018

7. AWS Standard A6.0, WELDING AND CUTTING

CONTAINERS WHICH HAVE HELD COMBUS-
TIBLES, obtainable from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL  33126

8. NFPA Standard 51, OXYGEN-FUEL GAS SYSTEMS

FOR WELDING, CUTTING AND ALLIED PRO-
CESSES, obtainable from the National Fire Protection
Association, Batterymarch Park, Quincy, MA  02269

9. NFPA Standard 70, NATIONAL ELECTRICAL CODE,

obtainable from the National Fire Protection Associa-
tion, Batterymarch Park, Quincy, MA  02269

10. NFPA Standard 51B, CUTTING AND WELDING PRO-

CESSES, obtainable from the National Fire Protection
Association, Batterymarch Park, Quincy, MA  02269

11. CGA Pamphlet P-1, SAFE HANDLING OF COM-

PRESSED GASES IN CYLINDERS, obtainable from the
Compressed Gas Association, 1235 Jefferson Davis
Highway, Suite 501, Arlington, VA 22202

12. CSA Standard W117.2, CODE FOR SAFETY IN WELD-

ING AND CUTTING, obtainable from the Canadian
Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3

13. NWSA booklet, WELDING SAFETY BIBLIOGRAPHY

obtainable from the National Welding Supply Associa-
tion, 1900 Arch Street, Philadelphia, PA 19103

14. American Welding Society Standard AWSF4.1, RECOM-

MENDED SAFE PRACTICES FOR THE PREPARA-
TION FOR WELDING AND CUTTING OF CONTAIN-
ERS AND PIPING THAT HAVE HELD HAZARDOUS
SUBSTANCES, obtainable from the American Welding
Society, 550 N.W. LeJeune Rd, Miami, FL  33126

15. ANSI Standard Z88.2, PRACTICE FOR RESPIRATORY

PROTECTION, obtainable from American National
Standards Institute, 1430 Broadway, New York, NY
10018

Содержание CutSkill PCH-42 Torch

Страница 1: ...PLASMA CUTSKILL Operation Manual C 35C PLASMA CUTTING SYSTEM Rev AA 01 Issue Date March 26 2007 Manual 0 4688 Operating Features...

Страница 2: ......

Страница 3: ...005 2006 2007 by Thermal Dynamics Corporation All rights reserved Reproduction of this work in whole or in part without written permission of the publisher is prohibited The publisher does not assume...

Страница 4: ......

Страница 5: ...ecifications 2 2 2 05 System Contents 2 2 2 06 Transporting Methods 2 2 SECTION 3 0 INSTALLATION 3 1 3 01 Site Selection 3 1 3 02 Electrical Input Connections 3 1 3 03 Torch 3 1 SECTION 4 0 OPERATION...

Страница 6: ......

Страница 7: ...head out of the welding fume plume Use an air supplied respirator if ventilation is not adequate to remove all fumes and gases The kinds of fumes and gases from the plasma arc depend on the kind of m...

Страница 8: ...this manual PLASMA ARC RAYS Plasma Arc Rays can injure your eyes and burn your skin The plasma arc process produces very bright ultra violet and infra red light These arc rays will damage your eyes a...

Страница 9: ...re Protection Association Batterymarch Park Quincy MA 02269 11 CGA Pamphlet P 1 SAFE HANDLING OF COM PRESSED GASES IN CYLINDERS obtainable from the Compressed Gas Association 1235 Jefferson Davis High...

Страница 10: ...s electrodes shield cups o rings start cartridges gas distributors fuses filters 2 Equipment that has been modified by an unauthorized party improperly installed improperly operated or misused based u...

Страница 11: ...ty 5 8 15 mm Dimension W D H 10 5 x15 5 x11 267 mm x 394 mm x 279 mm Gross Weight 57 lbs 26 kg Duty cycle 104 F 40 C Ambient NOTE Refer to Local and National Codes or local au thority having jurisdict...

Страница 12: ...n with exposed tip the recommended standoff height is 1 8 3 8 3 9 mm Plasma Power Supply Used With 35C PCH 42 Torch Ratings 2 05 System Contents Description ITEMS Q ty Power source Model 35C 1 Torch S...

Страница 13: ...source fuse and any extension cords used must conform to local electrical code and the recommended circuit protection and wir ing requirements as specified in Section 2 3 03 Torch Make sure that the t...

Страница 14: ...Installation 3 2 Manual 0 4688 This Page Left Blank...

Страница 15: ...is possible to have enough air pressure to op erate the power supply but not enough air flow to operate the torch Torch Switch Latch Indicator This indicator lights when the Torch Switch Latch Button...

Страница 16: ...k piece or cutting table Work Cable And Clamp Art A 04389 D Torch Operation Wear gloves and protective goggles Do not place bare hand on work piece 1 For drag cutting keep the torch in contact with th...

Страница 17: ...ghest setting and torch held at the indicated standoff height Unit Standoff Material Thickness ipm mm m ipm mm m 35C Drag 10 ga 0 135 3mm 94 7 2367 75 7 1893 35C Drag 7 ga 0 179 4 5mm 57 0 1425 45 6 1...

Страница 18: ...Operation 4 4 Manual 0 4688 This Page Left Blank...

Страница 19: ...Switch Off and then On again 3 Switch may be faulty a Return to an authorized service center for re pair B Primary power switch is on but the cooling fan does not work 1 No power incorrect power to f...

Страница 20: ...ble Work Cable And Clamp Art A 04389 3 Current sensor or PWM PCB faulty a Return to an authorized service center for re pair F Air flows continuously and torch switch latch button doesn t work properl...

Страница 21: ...ch On Compressor Starts and Air Flows at Torch Turn Air Set Switch Off Red Air Indicator Pilot Arc goes out Release Torch Switch Primary Input Power Switch Off or Unplugged Green Power Indicator Off a...

Страница 22: ...and air Lay unit on its side Remove two screws and access plate Pilot Power Supply Adapter Connections Negative Plasma Lead Art A 04695 DETAIL To Power Supply Adapter Pilot Negative Plasma Lead Black...

Страница 23: ...R G3 E4 E3 IGBT AIR ERROR IGBT AIR CHECK C5 C4 C4 C3 REACTOR GN_1 VC_1 Pilot Relay PILOT AB AC230 C8 TB2 C6 R6 Compressor Relay No 40276003 No 40270601 GN_1 No 40273003 VD_1 VC_1 Current Sensor FAN Pr...

Страница 24: ...E4 E3 IGBT AIR ERROR IGBT AIR CHECK C6 C5 C4 REACTOR GN_1 VC_1 Pilot Relay PILOT AC230 C1 TB2 C7 R7 Compressor Relay No 40276005 No 40270601 GN_1 No 40273003 VD_1 VC_1 Current Sensor FAN Pressure Sens...

Страница 25: ...trict Shanghai PR 200052 Telephone 86 21 69171135 Fax 86 21 69171139 Thermadyne Asia Sdn Bhd Lot 151 Jalan Industri 3 5A Rawang Integrated Industrial Park Jln Batu Arang 48000 Rawang Selangor Darul Eh...

Страница 26: ...Corporate Headquarters 16052 Swingley Ridge Road Suite 300 St Louis MO 63017 Telephone 636 728 3000 Email TDCSales Thermadyne com www thermadyne com...

Отзывы: