2.05 Input Wiring Specifications
CutMaster 82 Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I
1
eff
Fuse (amps)
Flexible Cord
(Min. AWG)
1 Phase
208
60
16
75
48
100
6
230
60
17
72
46
100
6
460
60
20
44
28
50
10
3 Phase
208
60
16
40
26
50
8
230
50/60
16
39
25
50
10
380
50/60
11.8
18
12
20
12
400
50/60
11.8
18
12
20
12
460
60
17
21
14
25
12
600
60
9.6
16
10
20
12
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
Содержание Cutmaster 82
Страница 2: ......
Страница 4: ...This Page Intentionally Blank...
Страница 8: ...TABLE OF CONTENTS...
Страница 16: ...cutmaster 82 GENERAL INFORMATION 1 8 Manual 0 4980...
Страница 24: ...CutMaster 82 INTRODUCTION 2T 4 Manual 0 4980 This Page Intentionally Blank...
Страница 36: ...CutMaster 82 OPERATION 4 4 Manual 0 4980 This Page Intentionally Blank...
Страница 54: ...CutMaster 82 OPERATION 4T 18 Manual 0 4980 This Page Intentionally Blank...
Страница 55: ...cutmaster 82 Manual 0 4980 5 1 SERVICE SECTION 5 SYSTEM SERVICE 5 01 General Maintenance...
Страница 79: ...cutmaster 82 Manual 0 4980 5 25 SERVICE This Page Intentionally Blank...
Страница 82: ...CutMaster 82 SERVICE 5 28 Manual 0 4980 This Page Intentionally Blank...
Страница 93: ...cutmaster 82 Manual 0 4980 6 9 PARTS LIST A 07994 6 1 4 2 3 5 7 8 9 10 12 11 10...
Страница 102: ...CutMaster 82 PARTS REPLACEMENT 7 8 Manual 0 4980 This Page Intentionally Blank...
Страница 107: ...cutmaster 82 Manual 0 4980 A 5 APPENDIX This Page Intentionally Blank...
Страница 110: ...CutMaster 82 APPENDIX A 8 Manual 0 4980 APPENDIX 6 SYSTEM SCHEMATIC 600V UNITS...
Страница 111: ...cutmaster 82 Manual 0 4980 A 9 APPENDIX...