Manual No. 0-4818 Auto-Cut 300
2
3-16
INSTALLATION
3.11 Set Switches on the Command - Control Module
Remove the power supply right side. Set switches on the CCM (Command-Control Module) per the illustrations.
Switch settings and connection details are provided in the Appendix.
CAUTION
Printed circuit boards in the Command - Control Module are static - sensitive. Discharge any built-up
static charges in your body or surroundings before touching the printed circuit boards.
SW1
SW3
SW4
SW5
SW8
3
4
1
2
3
4
1
2
1
2
1
2
1
2
1
2
SW-1-1: Auto Pilot Restart. 1 = ON = Auto Pilot Function enabled.
1 = OFF = Auto Pilot Function disabled (Factory default setting).
SW-1-2: Pilot Delay 2 = OFF, 3 = OFF, 4 = OFF: 0 Seconds (Factory default setting).
SW-1-3: Pilot Delay 2 = ON, 3 = OFF, 4 = OFF: 0.1 Seconds
SW-1-4: Pilot Delay 2 = OFF, 3 = ON, 4 = OFF: 0.2 Seconds
2 = ON, 3 = ON, 4 = OFF: 0.4 Seconds
2 = OFF, 3 = OFF, 4 = ON: 0.8 Seconds
2 = ON, 3 = OFF, 4 = ON: 1.0 Seconds
2 = OFF, 3 = ON, 4 = ON: 1.5 Seconds
2 = ON, 3 = ON, 4 = ON: 2.0 Seconds
SW-4: Postflow Time 1 = OFF, 2 = OFF: 10 Seconds (Factory default setting).
1 = ON, 2 = OFF: 20 Seconds
1 = OFF, 2 = ON: 5 Seconds
1 = ON, 2 = ON: 0 Seconds
SW-5-1: Tip Saver Reserved for Factory use.
SW-5-2: Off Plate
Reserved for Factory use.
SW 8-1: Pilot Time 1 = OFF = Short (85 ms.) (Factory default setting).
1 = ON = Long (3 s.)
O
N
O
N
Active only when
SW-1-1 is set to O N.
Art # A-06791_AB
Future Use
SW-3: Gas Preflow Time 1 = Off, 2 = OFF: 2 seconds
1 = ON, 2 = OFF: 4 seconds
1 = OFF, 2 = ON: 6 seconds
1 = ON, 2 = ON: 8 seconds
SW 8-2: Remote Current 1 = OFF = Disabled (Factory default setting).
1 = ON = (Remote Analog Current Control)
*SW 8-3: Auto Transfer Retry1 = OFF = Enabled Up to 3 tries (Factory default setting).
1 = ON = Disabled
SW 8-4:
Reserved for Factory use.
* SW 8-3 is reserved for
Factory use prior to
Firmware V3.5
Содержание AUTO-CUT 30 O2
Страница 4: ...Thispageintentionallyblank...
Страница 8: ...blank...
Страница 24: ...Manual No 0 4818 Auto Cut 3002 2 8 SPECIFICATIONS This Page Intentionally Blank...
Страница 68: ...Manual No 0 4818 Auto Cut 3002 3 44 INSTALLATION Intentionally Blank...
Страница 86: ...Intentionally Blank...
Страница 107: ...Manual No 0 4818 Auto Cut 3002 6 19 Parts List This page is blank intentionally...
Страница 124: ...Manual 0 4818 Auto Cut 3002 A 8 APPENDIX This page intentionally blank...
Страница 129: ...Manual 0 4818 Auto Cut 3002 A 13 APPENDIX This page intentionally blank...
Страница 147: ...This Page Intentionally Blank...