Description
Possible
Ca
use
Remedy
Remarks
4
E11 error code displayed
Over Prim
ary supply (input)
voltage at prim
ary capacitors is
exceeded for one second
Prim
ary supply voltage is
greater th
an the nom
inal
voltage plus 10%
Have an Accredited
Therm
al Arc Service Agent
or a qualified electrician
check the P
rim
ary voltag
e.
Weld curren
t ceases.
Buzzer sounds constantly.
Error cod
e E11
autom
atically will reset
when the voltage reduces.
5
E14 error code displayed
Under m
ains supply (input) voltage
warning prim
ary capacitors is
reduced for one second
Mains supp
ly voltage is less
than the nom
inal operating
voltage less 10%.
Have an Accredited
Therm
al Arc Service Agent
or a qualified electrician
check the Mains voltage.
Weld current available.
Buzzer sounds
interm
ittently.
Error cod
e E14
autom
atically will reset
when the voltage increases.
6
E12 error code displayed
Under m
ains supply (input) voltage
prim
ary capacito
rs is red
uced for
one second
Mains supply voltage is
down to a dangerously low
level.
A
B
Have an Accredited
Therm
al Arc Service Agent
or a qualified electrician
check the Mains voltage
Have an Accredited
Therm
al Arc Service Agent
or a qualified electrician
check the p
rim
ary cable &
fuses.
Weld curren
t ceases.
Buzzer sounds constantly.
Error cod
e E12
autom
atically will reset
when the voltage increases.
7
E81 error code displayed
W
rong Primary supply
(input)
voltage con
nected
When 3 phase m
achine is
first tu
rned on with the
wrong Primary supply
(input) voltage connected
Have an Accredited
Therm
al Arc Service Agent
or a qualified electrician
check the Mains voltage
No weld current is
available.
Buzzer sounds constantly.
Switch m
achine off.
8
E82 error code displayed
Link switch plug not connected
Link switch plug not
connected
Have an Accredited
Therm
al Arc Service Agent
check connector plug on
input PCB
No weld current is
available.
Buzzer sounds constantly.
Switch m
achine off.
PRO-LITE 250S
June 29, 2005
50
Содержание pro-life 250s
Страница 2: ......
Страница 16: ...THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 28: ...PAGE LEFT INTENTIONALLY BLANK PRO LITE 250S June 29 2005 28 ...
Страница 56: ...APPENDIX A INTERCONNECT DIAGRAM PRO LITE 250S June 29 2005 56 ...
Страница 57: ...PRO LITE 250S 57 June 29 2005 ...
Страница 59: ...Figure 11 Location of PCB WK 4921 PRO LITE 250S 59 June 29 2005 ...
Страница 60: ......