3.04 Specifications
Parameter 250S
Rated Output
Amperes
Volts
Duty Cycle
380/415VAC
250
30
40%
Duty Cycle
250A / 30V @ 40%
190A / 27V @ 60%
Output Current
5 – 250 Amps
Range
Open Circuit Voltage
57V @ 380VAC, 62V @ 415VAC
Dimensions
Width
Height
Length
7.08” (180mm)
14.17” (360mm)
16.54” (420mm)
Weight
39.68 lb. 18 kg
Output @ Rated Load
Output Amperes
Output Volts
Duty Cycle
KVA
KW
Three-phase
250A
30V
40%
12.5
9.4
Output @ No Load
KVA
KW
0.5
0.13
Input Volts Three Phase
380V
415V
Amperage Draw @ Rated Load
19
17
No Load
0.7
0.7
Thermal Arc continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the
specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment
previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items.
The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above
specifications due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured components,
installation location and conditions and local power grid supply conditions.
PRO-LITE 250S
June 29, 2005
26
Содержание pro-life 250s
Страница 2: ......
Страница 16: ...THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 28: ...PAGE LEFT INTENTIONALLY BLANK PRO LITE 250S June 29 2005 28 ...
Страница 56: ...APPENDIX A INTERCONNECT DIAGRAM PRO LITE 250S June 29 2005 56 ...
Страница 57: ...PRO LITE 250S 57 June 29 2005 ...
Страница 59: ...Figure 11 Location of PCB WK 4921 PRO LITE 250S 59 June 29 2005 ...
Страница 60: ......