Supply Voltages
On the MAPRO pcb all internal supply voltages are generated out of the control transformer output.
Schematic
Different supply voltages are monitored by the Microcontroller (Master) and the DSP (Process).
If the 24V drops below 17V the machine will stop and displays
E14
(Op. voltages error).
If the 24V are higher than 36V the machine will stop and displays
E02
(mains overvoltage).
Supply voltage Limit
Result
+24V DC
<17V
Shutdown with
E14
+24V DC
>36V
Shutdown with
E02
The actual values of the 24V and 15V can be checked via the front panel in menu Extras, Diagnosis, Op. Volta-
ges.