page 14
Pc-board DK-DCDRV / DK-S3DRV
The pc-board DK-DCDRV is managing the primary drive level of the power unit 400SP and 500SP.
The pc-board DK-S3DRV is managing the primary drive level of the power unit 320SP.
!!! CAUTION !!!
: there had been several changes at the boards, please read the detailed informations about the-
se changes on page 17.
Functions
- encoding power unit
- connection temperature sensor of heat sink
- supply current sensor
- monitoring bus voltage and supply voltage
- safety shut-down of power unit
- passthrough signal powerup relays
- passthrough signal „welding current on“ (from current sensor)
Encoding Power Unit
The type of the power unit is set via the DIP switch.
DIP 1
DIP 2
setting
machine type
OFF
OFF
240 A
400SP
OFF
ON
270 A
320SP
ON
OFF
300 A
500SP
ON
ON
reserved
LED displays
normal
LED
state
designation
1 (red)
off
primary overcurrent shut down
2 (green)
on
drive level of low-side is ok
4 (green)
on
bus voltage max is ok
5 (green)
on
drive level of high-side is ok
6 (green)
on
bus voltage min is ok
malfunction
LED
state
reason
1 (red)
on
primary current is too high, power unit has been switched off
2 (green)
never on no drive level low-side
4 (green)
off
bus voltage is too high (e.g. mains overvoltage)
5 (green)
never on no drive level high-side
6 (green)
off
bus voltage is too low (e.g. mains voltage too low)
Measuring Points
designation
measure point
result
supply voltage current sensor
X2/1
X2/6
+
gnd
+15V DC
supply voltage current sensor
X2/3
X2/6
-
gnd
-15V DC
temperature sensor
X3/1
X3/2
gnd
+
10k
Ω
at 25°C
(about +2V DC)
Содержание POWERMASTER 320SP